Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Euler-Euler model" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Multi-fluid Euler-Euler model of the blood flow within the blood vessel with rigid walls
Wielofazowy model przepływu krwi w naczyniu krwionośnym ze sztywnymi ścianami w podejściu Euler-Euler
Autorzy:
Gracka, Maria
Powiązania:
https://bibliotekanauki.pl/articles/101697.pdf
Data publikacji:
2016
Wydawca:
Politechnika Śląska. Wydział Inżynierii Środowiska i Energetyki. Instytut Techniki Cieplnej
Tematy:
CFD
Euler-Euler model
multi-fluid
blood flow
aorta
model Euler-Euler
przepływ wielofazowy
przepływ krwi
Opis:
The cardiovascular diseases and disorders such as atherosclerosis, strokes and heart attacks are the leading causes of death in the world mainly in the developed and industrialized societies. Understanding of basic mechanisms and phenomena occurring in the cardiovascular system could be useful in early detection of the development of lesions in blood vessels. In the presented work numerical analysis of blood flow within aorta has been made. Analysis included two models: single- and multi-phase approaches. In first blood was treated as a homogenous, non-Newtonian fluid with averaged rheological properties of viscosity and density. Second model uses an Eulerian multiphase approach in model of blood flow which assumes blood as a mixture of three phases (plasma, erythrocytes and leukocytes). To develop numerical model of blood flow within the human blood vessel the commercial software ANSYS Fluent (ANSYS Inc., USA) has been used. In the project the geometry of 8-year old patient with moderate thoracic aortic coarctation (approximately 65% area reduction) has been used. The geometry was created from data generated during Gadolinium-enhanced MR angiography (MRA). Model of the geometry includes ascending aorta, arch, descending aorta und upper branches such as innominate artery, left common artery, left subclavian artery. To reproduce periodic cardiac cycle as an inlet boundary condition velocity profile was used. Velocity profile was calculated from the conversion of the volumetric flow that was measured by a phase-contrast (PC) MRI sequence with through-plane velocity encoding. As the outlet boundary conditions for all branches and descending aorta the outflow condition was used. Volumetric share of blood flow through various outflows of the aortic model was measured via PC-MRI. Results of numerical simulation are presented for two characteristic points (during systole and diastole) of the cardiac cycle.
Choroby oraz zaburzenia układu krążenia, takie jak miażdżyca tętnic, udary i zawały serca są główną przyczyną zgonów na świecie, w szczególności w rozwiniętych i uprzemysłowionych społeczeństwach. Zrozumienie podstawowych mechanizmów i zjawisk występujących w układzie sercowo-naczyniowym może być przydatne do wczesnego wykrycia i diagnozy rozwijających się zmian w naczyniach krwionośnych. W prezentowanej pracy przeprowadzono analizę numeryczną przepływu krwi w aorcie. Wykonano dwa modele numeryczne pierwszy model traktujący krew jako jednorodną ciecz nienewtonowską z reologicznymi właściwościami średnimi dla lepkości i gęstości składników. Drugi model obejmuje analizę przepływu krwi będącej mieszaniną trzech faz (osocza, czerwonych krwinek oraz białych krwinek). Symulacje przeprowadzono przy użyciu komercyjnego oprogramowania ANSYS Fluent (ANSYS Inc., USA). W projekcie wykorzystano geometrię aorty 8-letniej pacjentki z koarktacją za łukiem aorty (zwężenie ok. 65%) wygenerowaną ze skanu wykonanego podczas wzmocnionej angiografii (MRA). Model obejmuje aortę wstępującą, łuk aorty, aortę zstępującą oraz górne odgałęzienia naczyń (pień ramiennogłowowy, tętnicę szyjną wspólną oraz podobojczykową lewą). W celu odwzorowania cyklu pracy serca na wlocie do aorty jako warunek brzegowy przyjęto profil prędkości przeliczony z przepływu objętościowego krwi, który zmierzono w trakcie badania kontrastem fazowym. Warunek zaimplementowano wykorzystując tzw. procedury własne (UDF - User Defined Function). Jako warunek brzegowy na wylotach przyjęto wypływy przez odgałęzienia oraz aortę zstępującą, których wartość wyrażona jest udziałem procentowym ze strumienia krwi na wlocie do aorty wstępującej. Wyniki symulacji numerycznej przedstawiono dla dwóch punktów charakterystycznych podczas skurczu i rozkurczu serca.
Źródło:
Archiwum Instytutu Techniki Cieplnej; 2016, 1; 29-51
2451-277X
Pojawia się w:
Archiwum Instytutu Techniki Cieplnej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Identification and modelling of blood flow processes in section of large blood vessel using hybrid Euler-Lagrange multiphase approach
Identyfikacja oraz modelowanie procesu przepływu krwi w części dużego naczynia krwionośnego z wykorzystaniem wielofazowego modelu hybrydowego Euler-Lagrange
Autorzy:
Knopek, Artur
Powiązania:
https://bibliotekanauki.pl/articles/101676.pdf
Data publikacji:
2016
Wydawca:
Politechnika Śląska. Wydział Inżynierii Środowiska i Energetyki. Instytut Techniki Cieplnej
Tematy:
aorta
CFD
blood flow
Ansys Fluent
multiphase
DPM
przepływ krwi
ANSYS Fluent
Euler-Lagrange’a system
Euler-Euler
Wielofazowy Model Eulera
Opis:
Computational fluid dynamics (CFD) in past known only in highly specialized technical engineering branch is nowadays one of main engineering tool in solving numerous complex problems in order to get crucial information and extend general knowledge in many fields. CFD allows to create new, more advanced systems and also optimize already created to enhance efficiency and/or reduce costs of production and operating. Actual situation demands from engineers to face difficult competition - fighting for minor fractions of efficiency due to construction and materials limitations. That operations do not concentrate only on that obvious disciplines like heat transfer, fluid dynamics or power-generation, but also new uncharted areas like automotive, chemical, aerospace, environmental engineering etc. One of that innovative field of CFD application is bio-engineering. In medicine, computer simulations can provide necessary, life-saving information with no interfere in patient body (in vivo), that allows to avoid later complications, application collisions and dangerous unpredictable after-effects. What more in several cases, in vitro analyses cannot be used through to life threats of treatment. The main objective of current project is to develop and test novel approach of accurate modelling of human blood flow in arteries. Currently available research reports do not cover the spatial interaction of individual blood phases and walls of blood vessels. Such approach could significantly reduce accuracy of such models. Proper simulations enriches general knowledge with specific details which could be crucial in early diagnosis of potential cardiac problems showing vulnerable zones (e.g. narrowed blood vessels). Such precise information are extremely difficult to obtain experimentally. Apart from multiphase concept of the project (that is considering every component of blood as separate phase assigning exceptional properties to each of them and determines relations between them) special attention was paid to the realism of geometry - considering the real system of the aortic segment (part of ascending aorta, aortic arch and part of thoracic aorta) including bifurcations. In addition a pulsating blood flow is being considered and implemented using built in UDF (User Defined Function) functionality of CFD code.
Obliczeniowa mechanika płynów (ang. CFD – Computational Fluid Dynamics) znana niegdyś tylko w wysoce wyspecjalizowanej technicznie branży jest jednym z podstawowych narzędzi inżynieryjnych w rozwiązywaniu wielu złożonych problemów, celem zdobycia kluczowych informacji i poszerzenia wiedzy ogólnej w wielu dziedzinach. CFD pozwala na tworzenie nowych, bardziej zaawansowanych systemów oraz na udoskonalanie już istniejących – poprawiając ich wydajność i/lub obniżając koszty produkcji oraz eksploatacji. Aktualna sytuacja wymaga od inżynierów zmierzenia się w trudnej dyscyplinie – walce o ułamki wydajności z powodu ograniczeń materiałowych i konstrukcyjnych. Przedsięwzięcia te nie koncentrują się jedynie na oczywistych dyscyplinach, takich jak przepływ ciepła, mechanika płynów czy wytwarzanie energii, ale także na nowych, niezbadanych sferach jak inżynieria motoryzacyjna, chemiczna, kosmiczna czy środowiska itd. Jednym z innowacyjnych zastosowań CFD jest bio-inżynieria. W medycynie, symulacje komputerowe są w stanie dostarczyć niezbędnych, nierzadko ratujących życie informacji, bez ingerencji w ciało pacjenta (in vitro), co pozwala uniknąć późniejszych komplikacji, zagrożeń występujących w trakcie wprowadzania przyrządów w ciało pacjenta czy niebezpiecznych nieprzewidywalnych powikłań. Ponad to w wielu przypadkach metody in vivo są niemożliwe do zastosowania ze względu na zagrożenie życia pacjenta. Głównym celem powyższego projektu było stworzenie i testy innowacyjnego, dokładnego modelu przepływu krwi w ludzkiej aorcie. Aktualnie dostępne badania nie uwzględniają przestrzennych interakcji pomiędzy poszczególnymi fazami krwi i ścianami naczyń krwionośnych. Takie podejście zdecydowanie zmniejsza dokładność tego typu modeli. Odpowiednie badania wzbogacają wiedzę ogólną o dokładne informacje , które mogą okazać się kluczowe we wczesnym diagnozowaniu problemów układu sercowo-naczyniowego, wskazując na potencjalnie podatne obszary (np. kurczące się naczynia krwionośne). Tak dokładne informacje są trudno dostępne do uzyskania na drodze badań. Poza wielofazowa koncepcją projektu, który rozpatruje każdy komponent krwi jako oddzielną fazę, przyporządkowując poszczególne właściwości do każdej z nich i uwzględniając ich wzajemne relacje, szczególną uwagę zwrócono na realistykę geometrii – zakładając rzeczywisty układ aortalny (część aorty wstępującej, łuk aortalny i część aorty zstępującej) uwzględniający bifurkację. Ponadto wprowadzono do modelu przepływ pulsacyjny za pomocą wbudowanej wewnętrznej funkcji programu. (ang. UDF – User Defined Function).
Źródło:
Archiwum Instytutu Techniki Cieplnej; 2016, 1; 53-80
2451-277X
Pojawia się w:
Archiwum Instytutu Techniki Cieplnej
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies