Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Zmudzki, J." wg kryterium: Autor


Wyświetlanie 1-4 z 4
Tytuł:
Distribution of forces on supporting teeth in the midpalatal expander during “Hyrax” screw pre-load
Autorzy:
Młynarek, K.
Żmudzki, J.
Powiązania:
https://bibliotekanauki.pl/articles/366987.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Komputerowej Nauki o Materiałach i Inżynierii Powierzchni w Gliwicach
Tematy:
rapid palatal expansion
Hyrax screw pre-load
stress
displacement
finite elements analysis
FEA
szybka ekspansja podniebienia
naprężenie
przemieszczenie
analiza elementów skończonych
Opis:
Purpose: The aim of the study was to determine forces which are transferred to supporting teeth during the treatment with the midpalatal device with Hyrax screw and to evaluate orthodontic and orthopaedic effects based on displacement analysis. Design/methodology/approach: The finite element method (FEM) was used to simulation the midpalatal expansion forces activated by the screw pre-loaded during a turn of 180° which corresponds to daily recommended value. Distribution of expansion forces of Hyrax device was calculated as reaction forces on elastic supports with stiffness corresponding to the teeth working on periodontal ligament in alveolar bone. Findings: On the basis of the displacement analysis was observed the movement of supporting teeth by a value higher than 0.1 mm which corresponds to the recommended daily value. The midpalatal suture splitting forces were determined on the first premolars with a value of 32.8 N and on the first premolars of 44.2 N. Research limitations/implications: The studies did not take into account the shape of palate other craniofacial bones and their stiffness. Practical implications: Adjusting the stiffness of the device to degree of ossification midpalatal suture and teeth mobility. Searching for new solutions which eliminate the negative phenomenon of tilting teeth during the expansion of maxilla and recommending a surgically assisted techniques. Originality/value: The simulation confirmed that treatment with Hyrax screw gives a uniform expansion with values of forces corresponded to stiffness of premolar and molar teeth. The studies have indicated a possibility of tendency to tilting the supporting teeth what is a negative phenomenon.
Źródło:
Journal of Achievements in Materials and Manufacturing Engineering; 2019, 93, 1-2; 26-31
1734-8412
Pojawia się w:
Journal of Achievements in Materials and Manufacturing Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
FEA of displacements and stresses of aortic heart valve leaflets during the opening phase
Autorzy:
Bialas, O.
Żmudzki, J.
Powiązania:
https://bibliotekanauki.pl/articles/368153.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Komputerowej Nauki o Materiałach i Inżynierii Powierzchni w Gliwicach
Tematy:
heart valve
aortic valve
leaflet material
FEA
simulation
zastawka serca
zastawka aortalna
analiza elementów skończonych
symulacja komputerowa
Opis:
Purpose: Modelling of biomechanical behaviour of heart valve materials aids improvement of biofunctional feature. The aim of the work was assessment of influence of material thickness of leaflets of artificial aortic valve on displacements and stresses during opening phase using finite element analysis (FEA). Design/methodology/approach: The model of aortic valve was developed on the basis of average anatomical valve shapes and dimensions. Nonlinear dynamic large displacements analysis with assumption of isotropic linear elastic material behaviour was used in simulation (Solidworks). The modulus of elasticity of 5.0 MPa was assumed and Poisson ratio set to 0.45. The rigidly supported leaflets was loaded by pressure increasing in the range 0-55 mmHg in time 0.1 s. Leaflets with material thickness 0.13 and 0.15 and 0.17 mm were analysed. The thickness was simulated with shell finite elements. Findings: The highest stresses were observed in the areas of fixation of the leaflets near the scaffold and were lower than dangerous value of fatigue of polyurethanes. Increasing the thickness of valve leaflet material in the range of 40 micrometres resulted in reduction of the valve outlet by almost 10 percent. Research limitations/implications: The FEA was limited to the isotropic linear-elastic behaviour of the material albeit can be used to assess leaflet deformation during dynamic load. Practical implications: Leaflets design may be start from efficient FEA which helps estimation of material impact on stress and fold formation which can affect local blood flow. Originality/value: Aortic heart valve leaflet material can be initially tested in dynamic conditions during opening phase with using FEA.
Źródło:
Journal of Achievements in Materials and Manufacturing Engineering; 2019, 92, 1-2; 29-35
1734-8412
Pojawia się w:
Journal of Achievements in Materials and Manufacturing Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
FEM numerical simulation of contact stresses between driving shaft and hub impeller of fuel pump
Autorzy:
Wiater, M.
Chladek, G.
Żmudzki, J.
Powiązania:
https://bibliotekanauki.pl/articles/2201038.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Komputerowej Nauki o Materiałach i Inżynierii Powierzchni w Gliwicach
Tematy:
fibre reinforcement composite
fuel pump
impeller
shaft
hub wear
contact stress
finite elements analysis
FEA
kompozyty wzmocnione włóknami
pompa paliwa
wirnik
wał
zużycie piasty
naprężenia kontaktowe
analiza elementów skończonych
Opis:
Purpose: The aim of the work was to test the contact stresses in the model system of the turbine hub cooperating with the fuel pump drive shaft. The hypothesis of the work was that, by means of FEA, it is possible to assess the contact stresses in the materials of the turbine hub and the fuel pump shaft during torque transmission. Design/methodology/approach: A turbine with fibre-reinforced polyphenylene sulphide (PPS) composite cooperating with a stainless steel shaft (X46Cr13/1.4034) in a commonly used D-flat shape joint was selected for the experimental research. To assess contact stresses, the CAD model (NX, Siemens) of the entire turbine was limited to the hub area. The drive shaft is supported in accordance with the bearing in the fuel pump, and the possibility of rotation about the axis along the length of the torque-producing magnet is taken away. The system was loaded with a torque of 200 Nmm on the turbine. The turbine hub and shaft were calculated, taking into account the phenomenon of contact detachment or slip at the value of the friction coefficient of 0.1. Findings: The pressure transmission area was found in the area at the edge of the flat surface D-flat and on the opposite side of the D-convexity. The contact stresses on the D-flat side reached values close to the composite strength. Research limitations/implications: The studies did not take into account the technological inaccuracies, thermal deformation, local material properties, and wear. The value of the friction coefficient was not measured in realistic conditions with fuel lubrication. Practical implications: FEA has been achieved, which allows to reduce the cost of experimental research. Originality/value: The proposed model allows for further studies of the influence of elasticity of various materials and structures on contact stresses in order to assess wear resistance.
Źródło:
Journal of Achievements in Materials and Manufacturing Engineering; 2022, 113, 1; 13--21
1734-8412
Pojawia się w:
Journal of Achievements in Materials and Manufacturing Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Finite element analysis of the impact of the properties of dental wedge materials on functional features
Autorzy:
Czerwiński, M.
Żmudzki, J.
Kwieciński, K.
Kowalczyk, M.
Powiązania:
https://bibliotekanauki.pl/articles/2175745.pdf
Data publikacji:
2021
Wydawca:
Stowarzyszenie Komputerowej Nauki o Materiałach i Inżynierii Powierzchni w Gliwicach
Tematy:
dental wedge material
friction
matrix
filling
seal
finite element analysis (FEA)
pressure
materiał klina dentystycznego
tarcie
matryca
wypełnienie
uszczelnienie
analiza elementów skończonych
ciśnienie
Opis:
Purpose: Defect of the interproximal wall of the tooth is filled with use the shaped matrix and wedge which seals bottom margin during filling. Better fit of the wedge and equalization of the pressure forces on the matrix is achieved by the compliance of the wedge structure through cuts and perforations and the use of silicone materials and unidirectionally expanded polytetrafluoroethylene (ePTFE). The work presents a methodology for model studies of the mechanics of dental wedges in order to evaluate and compare the impact of wedge materials on functional features. The hypothesis of the work was that the mechanical properties of ePTFE determine the effectiveness of the dental wedge. Design/methodology/approach: Effect of modulus of elasticity and friction coefficient of wedge and matrix materials on the functional features of the wedge was studied on the way Finite Element Analysis (FEA). Simulation included contact sliding between wedge and matrix what was simulated in nonlinear large displacements regime. The sealing evaluation criterion was the pressure distribution between the wedge and matrix below the lower edge of the defect. Displacement values were the criterion for the loss of convexity as a result of matrix deformation. Findings: The material for the wedge should be characterized by a low coefficient of friction, low elasticity (ensuring high compliance of the wedge) and at the same time the ability to large permanent deformations, which allows for plastic shaping of the matrix from the side of the defect in order to achieve the required wall convexity and the tangent point. Research limitations/implications: Results show tendency of phenomena in limitation to model simplification of the interdental gap and the ideal adhesion of the matrix to the tooth and linear elasticity of materials. Practical implications: The material that best meets the requirements is unidirectionally expanded polytetrafluoroethylene, which has one of the lowest coefficients of friction and very high plasticity necessary to shape the matrix from the inside of the cavity. Originality/value: Methodology of model study and criteria of functional characteristics of dental wedge was presented.
Źródło:
Archives of Materials Science and Engineering; 2021, 112, 1; 32--41
1897-2764
Pojawia się w:
Archives of Materials Science and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies