Tytuł:
Impact of ultrasonic field strength on the structural changes of disintegrated excess sludge
Wpływ natężenia pola UD na zmiany struktury dezintegrowanych osadów nadmiernych
Autorzy:
Barański, M.
Zawieja, I.
Wolny, L.
Powiązania:
https://bibliotekanauki.pl/articles/395741.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
osad nadmierny
stabilizacja beztlenowa
struktura osadów
excess sludge
sludge structure
physical conditioning
chemical oxygen demand (COD)
anaerobic stabilization
Opis:
Exposure of sludge to the ultrasonic field as a disintegrating factor before the mesophilic anaerobic stabilisation directly affects the increase in the susceptibility of sludge on the biochemical process of decomposition in the anaerobic conditions. Thanks to the use of sewage sludge pretreatment, an increase of the disintegration degree of sludge undergoing physical modifications is reached, as well as the intensification of biogas production. The aim of the study was to record changes in the structure of excess sludge tested, as well as the determination of disintegration degree [%] versus the strength of ultrasound wave [W/cm2]. An ultrasonic disintegrator VCX – 1500 (Sonics Company) was used in the investigation. The test substrate was excess sludge from the Central Wastewater Treatment Plant P.S.W. "WARTA" in Czestochowa. Two cycles of tests were conducted, which implement the following amplitude A= 7.85 [mikro]m and 39.25 [mikro]m and the time of sonification ts = 30 ÷ 360s. The most beneficial effect of ultrasound treatment on the excess sludge was noted for the amplitude A=39.25 [mikro]m and the sonication time 360s, which resulted in 83.25% degree of disintegration of excess sludge. For these parameters, the strenght of ultrasonic wave was 4.8 W/cm2. In addition, a large dispersion of sludge particles prepared with ultrasonic field and enlargement of the liquid phase in relation to unconditioned sludge were observed. The noted changes of structure correlate with the obtained degree of disintegration of the excess sludge.
Poddanie osadów działaniu pola ultradźwiękowego, jako czynnika dezitegrującego przed procesem mezofilowej stabilizacji beztlenowej wpływa bezpośrednio na zwiększenie podatności osadów na proces biochemicznego rozkładu w warunkach beztlenowych warunkując szybkość przebiegu fazy hydrolitycznej fermentacji metanowej. Dzięki zastosowaniu prekondycjonowania osadów ściekowych uzyskuje się wzrost stopnia przefermentowania osadów poddanych fizycznej modyfikacji, jak również intensyfikację produkcji biogazu. Celem prowadzonych badań przy użyciu dezintegratora ultradźwiękowego o mocy 1500W z automatycznym strojeniem typu VCX–1500 amerykańskiej firmy SONICS było zobrazowanie zmian zachodzących w strukturze osadów nadmiernych, jak również określenie wartości stopnia dezintegracji [%] od natężenia fali ultradźwiękowej [W/cm2]. Substratem badań był nadmierny osad czynny pochodzący z Centralnej Oczyszczalni Ścieków P.S.W. „WARTA” w Częstochowie. Przeprowadzono dwa cykle badawcze, w których zastosowano następujące amplitudy drgań A = 7,85 žm i 39,25 žm oraz czas nadźwiękawiania tn = 30 ÷ 360s. Najkorzy-stniejszy wpływ działania czynnego pola ultradźwiękowego na osady ściekowe odnotowano dla amplitudy A.39,25 žm oraz czasu sonifikacji 360s, dla których uzyskano 83,25% stopień dezintegracji osadów nadmiernych. Natężenie fali UD dla omawianych parametrów pola ultradźwiękowego wynosiło 4,8 W/cm2. Ponadto zaobserwowano znaczną dyspersję cząstek osadów preparowanych polem UD oraz powiększenie fazy ciekłej w odniesieniu do osadów niekondycjonowanych. Zmiany struktury korelowały z uzyskanym stopniem dezintegracji osadów nadmiernych.
Źródło:
Civil and Environmental Engineering Reports; 2011, 6; 117-126
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ termicznej hydrolizy na zmiany struktury osadów nadmiernych poddanych stabilizacji beztlenowej
Influence or thermal hydrolysis on the excess sludge structure during anaerobic stabilization
Autorzy:
Barański, M.
Zawieja, I.
Powiązania:
https://bibliotekanauki.pl/articles/297785.pdf
Data publikacji:
2010
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
osad nadmierny
struktura osadów
chemiczne zapotrzebowanie tlenu
ChZT
kondycjonowanie termiczne
stabilizacja beztlenowa
excess sludge
sludge structure
chemical oxygen demand
COD
thermal pretreatment
anaerobic stabilization
Opis:
Zastosowanie termicznej obróbki osadów przed procesem mezofilowej stabilizacji beztlenowej wpływa na zwiększenie podatności osadów na proces biochemicznego rozkładu w warunkach beztlenowych. W wyniku kondycjonowania osadów uzyskano wyższy stopień dezintegracji osadów poddanych działaniu podwyższonej temperatury w odniesieniu do stopnia dyspersji surowych osadów nadmiernych. W wodzie nadosadowej modyfikowanych termicznie osadów zaobserwowano wzrost wartości stężenia substancji organicznych w formie rozpuszczonej wyrażony przyrostem wartości chemicznego zapotrzebowania tlenu (ChZT) oraz lotnych kwasów tłuszczowych (LKT). Celem przeprowadzonych badań, mających charakter obserwacji mikroskopowych, było zobrazowanie oraz ocena zmian zachodzących w strukturze osadów nadmiernych podczas termicznej modyfikacji osadów oraz w kolejnych 10 dobach procesu stabilizacji beztlenowej. Substratem badań był nadmierny osad czynny pochodzący z Centralnej Oczyszczalni Ścieków P.S.W. "WARTA" w Częstochowie. W celu zainicjowania procesu stabilizacji osad nadmierny zaszczepiono osadem przefermentowanym, stanowiącym 10% mieszaniny badawczej. Badania przeprowadzono dla Mieszaniny I (osad nadmierny + osad przefermentowany) oraz Mieszaniny II (osad nadmierny kondycjonowany termicznie w temp. 70°C przez 1,5 h + osad przefermentowany).
Application of sludge thermal treatment before the mesophilic anaerobic stabilization process influenced on the increase of sludge susceptibility to biochemical decomposition in anaerobic conditions. In the result of thermal pretreatment the higher disintegration degree of sludge submitted to temperature action, in comparison to dispersion degree of raw excess sludge was observed. In the liquid phase of the sludge pretreated by the mentioned method, the increasing of concentration value of organic substances in soluble form was noticed. It was expressed by the increase of chemical oxygen demand (COD) value. The purpose of the microscope observation study was the estimation of the sludge structure changes during thermal modification as well as during successive days of 10 days' anaerobic stabilization process. The subject of the tests was excess active sludge coming from the waste water treatment plant P.S.W. "WARTA" in Czestochowa. The tests were conducted on a mixture of excessive and digested sewage that was subjected to mesophilic methane fermentation. The Mixture I (raw excess sludge + digested sludge) and the Mixture II (thermal pretreatment excess sludge at the temp 70°C through the period of 1.5 h + digested sludge) were submitted to the research.
Źródło:
Inżynieria i Ochrona Środowiska; 2010, 13, 2; 85-91
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pozyskiwanie biogazu w procesie stabilizacji beztlenowej termicznie modyfikowanych osadów ściekowych
Biogas generation during the anaerobic stabilization of thermally modified sewage sludge
Autorzy:
Zawieja, I.
Barański, M.
Małkowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/296705.pdf
Data publikacji:
2010
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
odnawialne źródła energii
OZE
biogaz
stabilizacja beztlenowa
kondycjonowanie termiczne
renewable energy sources
RES
biogas
anaerobic stabilization
thermal pretreatment
volatile fatty acids
VFAs
chemical oxygen demand
COD
Opis:
Wzrost stopnia dezintegracji poddanych termicznej modyfikacji osadów nadmiernych warunkuje ich podatność na biodegradację. Efektem dezintegracji jest zachodzący proces hydrolizy termicznej, wpływający bezpośrednio na szybkość przebiegu fazy hydrolitycznej stabilizacji beztlenowej, a w konsekwencji na efektywność fermentacji metanowej, powodujący wzrost stopnia przefermentowania osadów oraz produkcji biogazu. Celem prowadzonych badań była intensyfikacja produkcji biogazu podczas stabilizacji beztlenowej termicznie kondycjonowanych osadów nadmiernych. Substratem badań był nadmierny osad czynny pochodzący z Centralnej Oczyszczalni Ścieków P.S.W. "WARTA" w Częstochowie. W celu zainicjowania procesu stabilizacji osad nadmierny zaszczepiono osadem przefermentowanym, stanowiącym 10% mieszaniny badawczej. Na wstępie prowadzonych badań określono najkorzystniejsze warunki termicznej modyfikacji osadów nadmiernych. Przeprowadzono pięć cykli badawczych w temperaturach: 50, 60, 70, 80, 90°C i w przedziale czasowym 0,5 h. W kolejnym etapie badań przeprowadzono proces okresowej stabilizacji beztlenowej w komorze fermentacyjnej, w mezofilowym reżimie temperatur. Natomiast w celu zbadania zachodzących, w kolejnych 10 dobach stabilizacji, zmian parametrów fizyczno-chemicznych osadów proces fermentacji prowadzono w kolbach laboratoryjnych stanowiących komory fermentacyjne. Z badanego zakresu temperatur do dalszych badań wybrano temperaturę 50 i 70°C. Dla temperatury 50°C i najkorzystniejszego czasu kondycjonowania wynoszącego 2,5 h uzyskano odpowiednio ok. 9-krotny oraz 3,5-krotny wzrost wartości ChZT oraz LKT w odniesieniu do wartości początkowych, natomiast dla temperatury 70°C i najkorzystniejszego czasu kondycjonowania wynoszącego 1,5 h odpowiednio ok. 8,5-krotny oraz 3,5-krotny wzrost wartości ChZT oraz LKT. W wyniku poddania osadów procesowi 25-dobowej stabilizacji beztlenowej uzyskano dla badanych osadów następujący stopień przefermentowania: surowe osady nadmierne 45%, osady kondycjonowane termicznie w temperaturze 50 i 70°C przez okres odpowiednio 2,5 oraz 1,5 h: 55 i 46%. Jednostkowa produkcja biogazu dla ww. osadów wyniosła odpowiednio 0,4; 1,92 i 0,7 dm³/g s.m.o.
The increase of the disintegration degree of thermally pretreated excess sludge determines its susceptibility to biodegradation. Thermal hydrolysis process, directly affects on the course rate of hydrolytic phase during anaerobic stability, and consequently on the efficiency of methane fermentation, giving the increase of sludge digestion degree and biogas production. The aim of this study was the intensification of biogas production during anaerobic stabilization of thermally conditioned excess sludge. Test substrate of the research was excess sludge from the Central Wastewater Treatment Plant "Warta" in Czestochowa. In order to initiate the process of stabilization, the excess sludge was inoculated by digested sludge, constituting 10% of the test mixture. At the outset of the study the most favorable conditions for the thermal modification of excessive sludge was determined. Five cycles of testing for temperatures 50, 60, 70, 80, 90°C and time interval 0.5 h were carried out. In the next stage of the study, periodic stabilization process was conducted in anaerobic digester in the mesophilic temperature regime. During 10 days of acid fermentation, in laboratory flasks changes in physico-chemical parameters of digested sludge were examined. From the test temperature range two temperatures 50 and 70°C were selected for further study. For the temperature of 50°C and the conditioning best time of 2.5 h, approximately 9-fold and 3.5-fold increase of the COD and VFA values in relation to baseline values were obtained, whereas for the temperature of 70°C and the conditioning best time of 1.5 h respectively about 8.5-fold and 3.5-fold increase of the COD and VFA values were observed. As a result of 25-day anaerobic stabilization process the following digestion degrees were obtained: for raw excess sludge 45% for, deposits thermally conditioned at 50 and 70°C in periods of 2,5 h and 1.5 h: 55 and 46% respectively. The unit biogas production for the above sludge amounted to 0.4, 1.92. and 0.7 dm³/g o.d.m.
Źródło:
Inżynieria i Ochrona Środowiska; 2010, 13, 3; 185-196
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies