Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "alpha particles" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Determination of Track Density of Animal Bones using CN-85 Detector
Autorzy:
Kadhim, Yasser Ayad
Kadhim, Nada Farhan
Najam, Laith Ahmed
Powiązania:
https://bibliotekanauki.pl/articles/1076660.pdf
Data publikacji:
2019
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
CN-85 Detector
alpha emitters
alpha particles
bones
Opis:
The aim of the study is to calculate the alpha emitters in bone samples of some animals by counting the tracks of alpha particles emitted from radioactive nuclei (Pb-210, Po-210, Ra-226) using the CN-85 detector. The detectors were kept with the samples in closed clear plastic cups at a 2 cm distance for 60 days. The track density in the detector, and, hence, the alpha emitters from the bones were counted with an optical microscope after etching the detectors with an etchant solution (NaOH). The results showed that the optimum etching time of CN-85 when using to detect alpha emitted from natural radionuclides were 40 mins and the highest track density were found in chicken, beef, and sheep respectively.
Źródło:
World News of Natural Sciences; 2019, 26; 138-145
2543-5426
Pojawia się w:
World News of Natural Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development of crystals based on cesium iodide for measurements of gamma radiation and alpha particles
Autorzy:
Pereira, M. C. C.
Filho, T. M.
Hamada, M. M.
Powiązania:
https://bibliotekanauki.pl/articles/148098.pdf
Data publikacji:
2009
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
scintillator
crystals
gamma radiation
alpha particles
luminescence
Opis:
During the past 50 years, scintillators have been among the most important nuclear radiation detectors. Inorganic scintillators are widely used in experimental nuclear physics, high energy physics, nuclear medicine, nuclear tomography, environmental studies and many other fields of use. Scintillation crystals based on cesium iodide (CsI) are matters of relatively low hygroscopy, high atomic number, easy handling and low cost, characteristics that favor their use as radiation detectors. In this work, the growth of pure CsI crystals, CsI:Br and CsI:Pb, using the Bridgman technique, is described. Ions of divalent lead (Pb2+) doped in the crystal structures are efficient emission centers and their application as scintillators is still the reason for intensive studies. Recently, promising results have been found for crystals of CsI doped by bromine (Br) for their use as radiation detectors. The concentration of the bromine doping element (Br) was studied in the range from 1.5 × 10–1 M to 10–2 M and the lead (Pb) in the range from 10–2 M to 5 × 10–4 M. To evaluate the scintillators developed, systematic measurements were carried out for luminescence emission and luminescence decay time for gamma radiation, Vickers microhardness assays, and analysis of crystals response to the gamma radiation, in the energy range from 350 keV to 1330 keV, and alpha particles from a 241Am source, with energy of 5.54 MeV. The obtained values for luminescence decay time for CsI:Br and CsI:Pb crystals, were from 13 to 19 ns.
Źródło:
Nukleonika; 2009, 54, 3; 151-155
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation on polycarbonate nanomembrane production based on alpha particles irradiation
Autorzy:
Ziaie, F.
Shadman, M.
Yeganegi, S.
Mollaie, A.
Majdabadi, A.
Powiązania:
https://bibliotekanauki.pl/articles/148096.pdf
Data publikacji:
2009
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
track-etched membrane
micro/nanofilter
alpha particles
chemical etching
polycarbonate
Opis:
Track-etched membranes were prepared in the Dosimetry Laboratory of Agricultural, Medical and Industrial Research School by exposing polycarbonate (PC) films with a thickness of about 20 μm to alpha particles emitted from 241Am followed by chemical etching in sodium hydroxide (NaOH) at different temperatures and solution concentrations. The PC films were prepared using the method of chemical solving, forming and drying in a vacuum oven. The etching rate of PC was related to the concentration of etching solution, etching temperature and time. Therefore, a series of track-etched membranes were produced using different etching parameters. The relation between the etching rate and the etching parameters were established from experimental data and can be used to control the average pore sizes of the PC track-etched membrane. The pore sizes and their structures were studied by an optical microscope (OM) and a scanning electron microscope (SEM) and the obtained results indicated that the pores across the PC films are cylindrically shaped.
Źródło:
Nukleonika; 2009, 54, 3; 157-161
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies