Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Glowinski, Sebastian" wg kryterium: Autor


Wyświetlanie 1-1 z 1
Tytuł:
An exoskeleton arm optimal configuration determination using inverse kinematics and genetic algorithm
Autorzy:
Głowiński, Sebastian
Błażejewski, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/306968.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
algorytm genetyczny
kinematyka odwrotna
egzoszkielet
ramię
arm exoskeleton
genetic algorithm
inverse kinematics
Opis:
This paper deals with the kinematic modelling of an arm exoskeleton used for human rehabilitation. The biomechanics of the arm was studied and the 9 Degrees of Freedom model was obtained. The particular (optimal) exoskeleton arm configuration is needed, depending on patient abilities and possibility or other users activity. Methods: The model of upper arm was obtained by using Denavit–Hartenberg notation. The exoskeleton human arm was modelled in MathWorks package. The multicriteria optimization procedure was formulated to plan the motion of trajectory. In order to find the problem solution, an artificial intelligence method was used. Results: The optimal solutions were found applying a genetic algorithm. Two variants of motion with and the visualization of the change of joints angles were shown. By the use of genetic algorithms, movement trajectory with the Pareto-optimum solutions has been presented as well. Creating a utopia point, it was possible to select only one solution from Pareto-optimum results. Conclusions: The obtained results demonstrate the efficiency of the proposed approach that can be utilized to analyse the kinematics and dynamics of exoskeletons using the dedicated design process. Genetic algorithm solution could be implemented to command actuators, especially in the case of multi-criteria problems. Moreover, the effectiveness of this method should be evaluated in the future by real experiments.
Źródło:
Acta of Bioengineering and Biomechanics; 2019, 21, 1; 45-53
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-1 z 1

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies