Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "EPR dosimetry" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Application of alanine dosimetry in dose assessment for ocular melanoma patients undergoing proton radiotherapy : preliminary results
Autorzy:
Mierzwińska, G.
Kłodowska, M.
Michalec, B.
Pędracka, A.
Rydygier, M.
Swakoń, J.
Waligórski, M. P. R.
Powiązania:
https://bibliotekanauki.pl/articles/146382.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
alanine
EPR dosimetry
proton beam
proton radiotherapy
Quality Assurance (QA)
Opis:
Basing on alanine solid state/electron paramagnetic resonance (EPR) dosimetry, a supplementary method of cumulatively recording the therapeutic dose received by ocular cancer patients undergoing fractionated proton radiotherapy is proposed. By applying alanine dosimetry during the delivery of consecutive fractions, the dose received within each fraction can be read out by EPR spectrometry and a fi nal permanent cumulative record of the total dose delivered obtained. The dose response of the alanine detector was found to be practically independent on its position within the extended proton Bragg peak region. Dose measurements based on entrance dose recorded in proton beams individually formed for each patient are presented. The described method will be applied as a complementary Quality Assurance procedure for patients undergoing proton radiotherapy at the Institute of Nuclear Physics, Polish Academy of Sciences, Krakow, Poland (IFJ PAN).
Źródło:
Nukleonika; 2015, 60, No. 3, part 2; 609-613
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Taurine-EVA copolymer-paraffin rods dosimeters for EPR high-dose radiation dosimetr
Autorzy:
Maghraby, A. M.
Mansour, A.
Abdel-Fattah, A. A.
Powiązania:
https://bibliotekanauki.pl/articles/147366.pdf
Data publikacji:
2014
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
EPR
ESR
radiation dosimetry
taurine
alanine
Opis:
Taurine/EPR rods (3 × 10 mm) have been prepared by a simple technique in the laboratory where taurine powder was mixed with a molten mixture of paraffin wax and an ethylene vinyl acetate (EVA) copolymer. The binding mixture EVA/Paraffin does not present interference or noise in the EPR signal before or after irradiation. The rods show good mechanical properties for safe and multi-use handling. An EPR investigation of radiation induced radicals in taurine rods revealed that there are two types of radicals produced after exposure to gamma radiation (60Co). EPR spectra were recorded and analyzed – also the microwave power saturation and modulation amplitude were studied and optimized. Response of taurine to different radiation doses (1.5–100 kGy) was studied and found to follow a linear relationship up to 100 kGy. Radiation induced radicals in taurine persists and showed a noticeable stability over 94 days following irradiation. Uncertainities associated with the evaluation of radiation doses using taurine dosimeters were discussed and tabulated. It was found that taurine possesses good dosimetric properties using EPR spectroscopy in high doses in addition to its simple spectrum.
Źródło:
Nukleonika; 2014, 59, 1; 9-13
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Alanine dosimetry of 60 MeV proton beam - preliminary results
Autorzy:
Michalec, B.
Mierzwińska, G.
Sowa, U.
Ptaszkiewicz, M.
Nowak, T.
Swakoń, J.
Powiązania:
https://bibliotekanauki.pl/articles/146730.pdf
Data publikacji:
2012
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
alanine
dosimetry
electron paramagnetic resonance (EPR)
proton beam
Opis:
Electron paramagnetic resonance (EPR) spectrometry (X-band) was used to determine the dose absorbed in alanine detectors, of different shapes and different alanine content, irradiated with Co-60 gamma rays and in a 60 MeV proton beam. The goal of our study was to confirm applicability of alanine as a passive detector in therapeutic proton beam. In the paper dose response characteristic and relative efficiency of alanine are shown. The study confirmed that alanine detectors with a high alanine content (ca. 95%) may be a useful and convenient tool for dose measurements in proton beams, used for eye cancer treatment.
Źródło:
Nukleonika; 2012, 57, 4; 503-506
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies