Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "zero-valent iron" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Desalination of groundwater and impoundments using Nano-Zero Valent Iron, n-Fe°
Autorzy:
Antia, D.D.J.
Powiązania:
https://bibliotekanauki.pl/articles/108538.pdf
Data publikacji:
2015
Wydawca:
Instytut Meteorologii i Gospodarki Wodnej - Państwowy Instytut Badawczy
Tematy:
desalination
zero-valent iron
ZVI
diffusion
saline aquifers
saline impoundments
Opis:
Salinization of groundwater is a major problem, particularly in areas with limited infrastructure. 14 diffusion reactors are operated diabatically at -8°C to 20°C to determine the amount of NaCl removed by n-Fe°. The reactors establish NaCl removal by Fe°: (i) 44,000-77,000 nm particle size (PS) = 0.0675-0.1925 g L-1 [feed water (FW) = 0.89 g L-1]; (ii) 50 nm PS = 0.953-1.14 g L-1 [FW = 1.095-1.19 g L-1]; (iii) 50 nm PS under nitrogen saturation (0.1-0.2 MPa) = 9.693 g L-1 [FW = 10 g L-1]; (iv) <0.01 g 50 nm PS L-1 under nitrogen saturation (0.1-0.2 MPa) = 1.564 g L-1 [FW = 4 g L-1]; (v) 50 nm PS modified by nitrogen saturation (PSN) = 5.52 g L-1 [FW = 6.89 g L-1]. Desalination commences at a time, t, after the n-Fe° is added to the water, and continues with an exponential decline until a base (equilibrium) salinity is reached. The effectiveness of n-Fe° as a desalination agent appears to increase with increased water salinity. Placement of PSN in an existing impoundment, or aquifer, may provide a cost effective, zero energy, partial desalination solution, which can be used to support emergency relief, agriculture and extractive industries.
Źródło:
Meteorology Hydrology and Water Management. Research and Operational Applications; 2015, 3, 1; 21-38
2299-3835
2353-5652
Pojawia się w:
Meteorology Hydrology and Water Management. Research and Operational Applications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Automotive fleet repair facility wastewater treatment using air/ZVI and air/ZVI/H2O2 processes
Oczyszczanie ścieków z zakładów naprawczych floty samochodowej z wykorzystaniem procesów powietrze/ZVI i powietrze/ZVI/H2O2
Autorzy:
Bogacki, J. P.
Al-Hazmi, H.
Powiązania:
https://bibliotekanauki.pl/articles/205311.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wastewater treatment
zero-valent iron
advanced oxidation processes
AOP
ZVI
oczyszczanie ścieków
żelazo metaliczne
zaawansowane procesy utleniania
Opis:
Advanced automotive fleet repair facility wastewater treatment was investigated with Zero-Valent Iron/Hydrogen Peroxide (Air/ZVI/H2O2) process for different process parameters: ZVI and H2O2 doses, time, pH. The highest Chemical Oxygen Demand (COD) removal efficiency, 76%, was achieved for ZVI/H2O2 doses 4000/1900 mg/L, 120 min process time, pH 3.0. COD decreased from 933 to 227 mg/L. In optimal process conditions odor and color were also completely removed. COD removal efficiency was increasing with ZVI dose. Change pH value below and over 3.0 causes a rapid decrease in the treatment effectiveness. The Air/ZVI/H2O2 process kinetics can be described as d[COD]/dt = -a [COD]tm, where ‘t’ corresponds with time and ‘a’ and ‘m’ are constants that depend on the initial reagent concentrations. H2O2 influence on process effect was assessed. COD removal could be up to 40% (560 mg/L) for Air/ZVI process. The FeCl3 coagulation effect was also evaluated. The best coagulation results were obtained for 700 mg/L Fe3+ dose, that was slightly higher than dissolved Fe used in ZVI/H2O2 process. COD was decreased to 509 mg/L.
Ścieki z zakładu naprawczego floty samochodowej poddano oczyszczaniu z wykorzystaniem żelaza metalicznego i nadtlenku wodoru (Air/ZVI/H2O2). Badano wpływ dawki żelaza i nadtlenku wodoru, czasu i pH na efektywność procesu. Największy stopień usunięcia ChZT, 76%, uzyskano dla dawek ZVI/H2O2 4000/1900 mg/L, czasu 120 min i pH 3.0. ChZT zmniejszono z 933 do 227 mg/L. Dodatkowo uzyskano całkowite usunięcie barwy i zapachu. Skuteczność usunięcia ChZT rosła wraz ze wzrostem zastosowanej dawki ZVI. Zmiana pH na inne niż 3, powoduje gwałtowne zmniejszenie efektywności procesu. Kinetyka procesu może zostać opisana z wykorzystaniem równania d[COD]/dt = -a [COD]tm, gdzie ‘t’ oznacza czas a ‘a’ i ‘m’ są stałymi zależnymi od początkowego stężenia reagentów. Badano także wpływ H2O2 na efektywność procesu. Skuteczność usunięcia ChZT wynosi 40% (560 mg/L) w przypadku zastosowania ZVI bez dodatku H2O2. Określono także skuteczność koagulacji z wykorzystaniem FeCl3. Najlepsze rezultaty uzyskano dla dawki Fe3+ 700 mg/L, zmniejszając ChZT do 509 mg/L.
Źródło:
Archives of Environmental Protection; 2017, 43, 3; 24-31
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies