Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "X-ray analysis," wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Statistical Assessment of the Microstructure of Barite Aggregate from Different Deposits Using X-Ray Microtomography and Optical Microscopy
Autorzy:
Żołek, N.
Ranachowski, Z.
Ranachowski, P.
Jóźwiak-Niedźwiedzka, D.
Kudela, S. jr.
Dvorak, T.
Powiązania:
https://bibliotekanauki.pl/articles/351890.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
barite ore
barite aggregate
microstructure
optical microscopy
thin sections analysis
X-ray tomography
Opis:
Two different barite ore (barium sulfate BaSO4) specimens from different localizations were tested and described in this paper. Analysis of the microstructure was performed on polished sections, and on thin sections using X-ray microtomography (micro-CT), and optical microscopy (MO). Microtomography allowed obtaining three-dimensional images of the barite aggregate specimens. In the tomograms, the spatial distribution of the other polluting phases, empty space as well as cracks, pores, and voids – that exceeded ten micrometers of diameter-were possible to visualize. Also, the micro-CT allowed distinguishing between minerals of different density, like SiO2 and BaSO4. Images obtained and analyzed on thin sections with various methods using the optical microscopy in transmitted light delivered additional information on the aggregate microstructure, i.e. allow for estimation of the different kinds of inclusions (like the different density of the minerals) in the investigated specimens. Above methods, which were used in the tests, completed each another in order to supply a set of information on inclusions’ distribution and to present the important differences of the barite aggregate specimens microstructure.
Źródło:
Archives of Metallurgy and Materials; 2017, 62, 2A; 697-702
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study on the State of Internal Stress and Strain of TATB-based Polymer Bonded Explosive Using Strain Markers and Cone-Beam Computed Tomography
Autorzy:
Dai, B.
Lan, L.-G.
Zhang, W.-B.
Tian, Y.
Powiązania:
https://bibliotekanauki.pl/articles/358613.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Przemysłu Organicznego
Tematy:
technology of materials
testing and analysis
compression molding
polymer bonded explosive
stress state
strain ellipsoid
X-ray tomography
Opis:
Precise measurement of the inner structural strain of polymer bonded explosive (PBXs) granules during compression molding is highly desirable in order to investigate the inner stress distribution field and its underlying generation mechanism, with the aim of improving the stress distribution uniformity. In this contribution, TATB-based (1,3,5-triamino-2,4,6-trinitrobenzene) PBX granules were formulated and the stress-strain state of the PBX granules during the warm molding process was analyzed. Strain markers were implanted at different locations and the deformation characteristics and regularity of the embedded spherical strain markers were obtained by X-ray micro-tomography. Thus the local strain states at different locations could be obtained, and the local stress state could be deduced. The results showed that axisymmetric deformation occurred in all of the strain markers, where the flat strain ellipsoids were mainly compressed uni-axially. In the central region, the stress was mainly in an axial direction, and the shear force was small. Not only axial stresses, but also large shear stresses in the surrounding region of the cylindrical grains were present. The stress gradient in the central region was greater than that in the surrounding region. The stress was greater in the surrounding region because this region was squeezed by the mold. The maximum strain degree was 44.8% larger than the minimum strain degree. The local stress increment in each region was quantified. The stress increments of the three axes were in the range 14.2-19.5 MPa. This study examined the feasibility of evaluating the inner stress–strain state of PBX granules in a quantitative manner, which is significant in determining the inner strain and stress distribution in PBX granules during the molding process.
Źródło:
Central European Journal of Energetic Materials; 2017, 14, 3; 688-707
1733-7178
Pojawia się w:
Central European Journal of Energetic Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Shape accuracy in single point incremental forming of conical frustums from titanium CP2 sheets
Dokładność kształtu w jednopunktowym kształtowaniu przyrostowym stożków ściętych z blach tytanowych CP2
Autorzy:
Szpunar, Marcin
Balcerzak, Maciej
Żaba, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/2204384.pdf
Data publikacji:
2022
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
incremental sheet forming
titanium
springback
optical forming analysis
X-ray tomography
kształtowanie przyrostowe blach
tytan
sprężynowanie
analizy optyczne kształtowania
tomografia komputerowa
Opis:
This paper presents frustum cone drawpiece analysis made of titanium CP2 sheet by a single incremental sheet forming. Central composite design has been adopted to carry out an experiment containing 20 runs, then multi-criteria parameter optimization has been done. Optimal parameters have been validated and responses deviations do not exceed 4% compared to created models. For the drawpiece formed with optimal parameters, AGRUS optical measurement and X-ray tomography has been applied to check the obtained of the part wall thickness and general deviations compared to the CAD model. The wall angle discrepancy of the cone generatrix has also been analyzed. No gaps or ruptures have been confirmed by X-ray. The blank rolling direction has a significant effect on the drawpiece deviations. The measurement results showed deviations of the drawpiece wall angle +0.27°/- 0.06°, sheet thickness on the cone +0.012/-0.04 mm and +0.151/-0.096 mm from the reference CAD geometry.
W pracy przedstawiono analizę wytłoczek w kształcie stożka ściętego wykonanego z blachy tytanowej CP2 metodą jednopunktowego przyrostowego kształtowania. Do przeprowadzenia eksperymentu obejmującego 20 przebiegów przyjęto centralny plan kompozycyjny, następnie dokonano wielokryterialnej optymalizacji parametrów. Dokonano walidacji optymalnych parametrów, a uzyskane wyniki nie przekraczają 4% w odniesieniu do stworzonych modeli. Dla wytłoczki uformowanej z optymalnymi parametrami zastosowano pomiar optyczny AGRUS oraz tomografię rentgenowską w celu sprawdzenia uzyskanej grubości ścianki wytłoczki i odchyłek w porównaniu z modelem CAD. Przeanalizowano również rozbieżność kątów ścian tworzących stożka. Za pomocą skanu rentgenowskiego potwierdzono brak szczelin i pęknięć wytłoczki. Kierunek walcowania półfabrykatu ma istotny wpływ na odchyłki. Wyniki pomiarów wykazały odchylenia kąta ścianki wytłoczki +0,27/-0,06°, grubości ścianki na stożku +0.012/-0.04 mm oraz +0.151/-0.096 mm od geometrii referencyjnej CAD.
Źródło:
Zeszyty Naukowe Politechniki Rzeszowskiej. Mechanika; 2022, z. 94; 63--75
0209-2689
2300-5211
Pojawia się w:
Zeszyty Naukowe Politechniki Rzeszowskiej. Mechanika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of X-Ray Microtomography and Optical Microscopy to Determine the Microstructure of Concrete Penetrated by Carbon Dioxide
Zastosowanie mikrotomografii komputerowej i mikroskopii optycznej do oceny mikrostruktury betonów poddanych działaniu CO2
Autorzy:
Ranachowski, Z.
Jóźwiak-Niedźwiedzka, D.
Ranachowski, P.
Rejmund, F.
Dąbrowski, M.
Kudela, S. jr.
Dvorak, T.
Powiązania:
https://bibliotekanauki.pl/articles/351864.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cement-matrix composites
concrete deterioration
X-ray tomography
microscopic analysis
concrete microstructure
kompozyty cementowe
zniszczenie betonu
tomografia rentgenowska
analiza mikroskopowa
mikrostruktura betonu
Opis:
In the paper two advanced methods for testing cement based composites are described and compared. These are X-ray microtomography and optical microscopy. Microtomography supplies three-dimensional images of small concrete specimens. In the tomograms all cracks, pores and other voids and inclusions, that exceed a few micrometers, are shown. Such visualisation can become a valuable tool for analysis of the basic material properties. Images obtained on thin sections and analysed with various methods on optical microscopes supply additional information on material microstructure that cannot be obtained in tomograms. For example it is relatively easy to determine zone penetrated by CO2 ingress. These two methods, presented on examples of tests, complete each another in order to supply a set of information on composition and defects of tested composite materials.
W artykule przedstawiono dwie nowoczesne metody analizy struktury materiałów kompozytowych ze spoiwem na bazie cementu. Są to mikrotomografia komputerowa oraz optyczna analiza cienkich szlifów. Mikrotomografia pozwala na uzyskanie trójwymiarowych obrazów niewielkich próbek betonowych. Na tomogramach widoczne są układy rys, porów i innych pustek, których wymiary przekraczają kilka mikrometrów. Przestawienie tych obiektów w przestrzeni jest ważnym narzędziem do analizy podstawowych właściwosci materiału. Obrazy uzyskane na cienkich szlifach w mikroskopie optycznym, analizowane następnie różnymi metodami, dostarczają dodatkowych informacji o mikrostrukturze materiału, które nie mogą być dostrzeżone na tomogramach. Stosunkowo łatwo jest np. uzyskac obrazy stref skarbonatyzowanej matrycy cementowej. Obie przedstawione metody uzupełniają się wzajemnie i pozwalają na otrzymanie zbioru informacji o składzie i defektach badanych materiałów kompozytowych.
Źródło:
Archives of Metallurgy and Materials; 2014, 59, 4; 1441-1447
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies