Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "X- ray" wg kryterium: Temat


Tytuł:
Metody badania porowatości odlewanych ciśnieniowo wyrobów ze stopu magnezu AM50
Porosity testing methods of magnesium alloy AM50 made by casting pressure
Autorzy:
Sozańska, L.
Mazurkiewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/134841.pdf
Data publikacji:
2016
Wydawca:
ADVSEO
Tematy:
magnesium alloys
pressure casting
porosity
acoustic microscopy
X-ray tomography
Opis:
There is an increasing interest in casting pressure elements in the automotive and household industry. Mechanical properties, implementation precision and quality play major role here. Unfortunately, this manufacturing technology is accompanied with disadvantageous features of the material structure as porosity, which must be controlled during production. On the basis of comparative studies of three selected research methods the most optimal research method for this group of products and materials was selected. It is a technique based on acoustic microscopy which, allows for the research of large components in the X and Y axes and a relatively high Z-axis. The research enables an analysis of all components without necessity of cutting a product into smaller elements subjected to separate analysis.
Źródło:
Technical Issues; 2016, 4; 89-95
2392-3954
Pojawia się w:
Technical Issues
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simulation of computed tomography (CT) images using a Monte Carlo approach
Autorzy:
Wysocka-Rabin, A. M.
Qamhiyeh, S.
Jäkel, O.
Powiązania:
https://bibliotekanauki.pl/articles/147601.pdf
Data publikacji:
2011
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
X-ray tomography
Monte Carlo (MC) method
treatment planning
hadrontherapy
Opis:
Heavy ion treatment planning uses an empirical scanner-dependent calibration relation between computed tomography (CT) numbers and ion range. Any deviation in the values of CT numbers will cause a drift in the calibration curve of the CT scanner, which can reduce the accuracy of treatment beam delivery. To reduce uncertainty in the empirical estimation of CT numbers, we developed a simulation that takes into consideration the geometry, composition, and physical process that underlie their measurement. This approach uses Monte Carlo (MC) simulations, followed by a simple filtered back-projection reconstruction. The MC code used is BEAMnrc/EGSnrc. With the manufacturer’s permission, we simulated the components (X-ray tube, associated filters and beam shapers) of a Siemens Emotion CT. We then generated an initial beam shape and spectra, and performed further simulations using the phantom with substitutes. We analyzed the resulting phase space file to calculate projections, taking into account the energy response of the CT detectors. Then, we applied a simple reconstruction algorithm to the calculated projections in order to receive the CT image.
Źródło:
Nukleonika; 2011, 56, 4; 299-304
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Monte Carlo calculated CT numbers for improved heavy ion treatment planning
Autorzy:
Qamhiyeh, S.
Wysocka-Rabin, A.
Jäkel, O.
Powiązania:
https://bibliotekanauki.pl/articles/148658.pdf
Data publikacji:
2014
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
X-ray tomography
Monte Carlo (MC) method
treatment planning
hadrontherapy
Opis:
Better knowledge of CT number values and their uncertainties can be applied to improve heavy ion treatment planning. We developed a novel method to calculate CT numbers for a computed tomography (CT) scanner using the Monte Carlo (MC) code, BEAMnrc/EGSnrc. To generate the initial beam shape and spectra we conducted full simulations of an X-ray tube, filters and beam shapers for a Siemens Emotion CT. The simulation output files were analyzed to calculate projections of a phantom with inserts. A simple reconstruction algorithm (FBP using a Ram-Lak filter) was applied to calculate the pixel values, which represent an attenuation coefficient, normalized in such a way to give zero for water (Hounsfield unit (HU)). Measured and Monte Carlo calculated CT numbers were compared. The average deviation between measured and simulated CT numbers was 4 ± 4 HU and the standard deviation σ was 49 ± 4 HU. The simulation also correctly predicted the behaviour of H-materials compared to a Gammex tissue substitutes. We believe the developed approach represents a useful new tool for evaluating the effect of CT scanner and phantom parameters on CT number values.
Źródło:
Nukleonika; 2014, 59, 1; 15-23
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical study on closed cell foam structure damage mechanisms
Autorzy:
Miedzińska, D.
Powiązania:
https://bibliotekanauki.pl/articles/246654.pdf
Data publikacji:
2012
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
closed cell foam
finite element method
X-ray tomography
damage
Opis:
Metallic foams are currently being looked at as a new material for automobiles. The main goal of the use of metallic foams in vehicles is to increase sound dampening, reduce the weight of the automobile, and increase energy absorption in case of crashes, or in military applications, to combat the concussive force of IEDs. The metallic foams that are being looked at currently, are aluminum and its alloys due to their low density (0.4-0.9 g/cm3). In addition these foams have a high stiffness, are fire resistant, do not give off toxic fumes, are fully recyclable, have high energy absorbance, have low thermal conductivity, have low magnetic permeability, and are efficient at sound dampening, especially in comparison to light weight hollow parts. In addition, partial addition of metallic foams in hollow parts of the car will decrease weakness points usually associated with car crashes and noisy vibrations. These foams are cheap to cast by using powder metallurgy (as compared to casting of other hollow parts). The aim of the research was to describe and to assess the main mechanisms that appear in the foam structure during the compression. The development process of the finite element model of the closed cell foam microstructure is presented in the paper. The model geometry was based on the real structure research, which was carried out with the use of computed tomography. The model was built with the use of a unique computer code created to transform the scan point cloud into FE raster model based on solid 8-node elements. The experimental and numerical compression test results were compared and showed good compatibility. The stress distributions were studied to describe the main mechanisms in the structure.
Źródło:
Journal of KONES; 2012, 19, 2; 321-327
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A study on fibre-reinforced concrete elements properties based on the case of habitat modules in the underwater sills
Autorzy:
Kurpińska, Marzena
Grzyl, Beata
Kristowski, Adam
Powiązania:
https://bibliotekanauki.pl/articles/259547.pdf
Data publikacji:
2020
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
hydrotechnical constructions
fibre-concrete
mechanical concrete
strength
X-ray tomography
Opis:
Hydrotechnical constructions are mostly objects functioning in extreme conditions and requiring a custom-made construction project. In the case of using prefabricated elements, it is required to develop production, transport, assembly, conservation and repair technology. Concerning the problem of concrete cracks, modern repair systems allow positive effects to be achieved in many cases of concrete elements repair. In this work an attempt has been made to assess the properties of concrete, situated in the Baltic Sea environment, in which traditional rebar was partly replaced by dispersed fibre-phase. Fibre-reinforced concrete belongs to the group of composite materials. The presence of fibres helps to increase the tensile strength, flexural strength and resilience and also prevents the appearance of cracks. In the given paper we will also discuss basic parameters of steel and polymer fibres and the influence of both types of fibres on the maturing and hardened concrete. In this work special attention has been paid to the advantages of polypropylene and polymer fibres with regard to commonly-known steel fibres. The use of synthetic fibres will be advantageous in constructions where the reduction of shrinkage cracks and high resilience are essential. On top of that, the use of synthetic fibres is highly recommended when constructing objects that will be exposed to the impact of an aggressive environment. Undoubtedly, polymer fibres are resistant to the majority of corrosive environments. Fibre-reinforced concretes are a frequently implemented construction solution. The possibility of concrete modification allows the emergence of new construction materials with improved physical-mechanical properties, under the condition of being applied relevantly.
Źródło:
Polish Maritime Research; 2020, 1; 143-151
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of Nonmetallic Inclusions in Aluminum–Silicon Alloys
Autorzy:
Galek, Tomasz
Łączek, Andrzej
Łysiak, Karol
Powiązania:
https://bibliotekanauki.pl/articles/176066.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
aluminum–silicon alloy
nonmetallic inclusions
scanning electron microscopy
X-ray tomography
Opis:
In this article, a study of nonmetallic inclusions introduced during the casting process of the aluminum–silicon alloy is presented. The samples were investigated using a scanning electron microscope to find the chemical composition and X-ray tomography to check the volumetric content of the non-metallic inclusions. The samples were made from AlSi7Mg alloy, used for car wheels, with 7% weight content of Si, 89% of Al, and 0.3% of Mg. The main goal of our investigations was to find out the chemical composition of the impurities and to identify the stage of the casting process at which the impurities are introduced.
Źródło:
Advances in Manufacturing Science and Technology; 2020, 44, 1; 28-31
0137-4478
Pojawia się w:
Advances in Manufacturing Science and Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Statistical Assessment of the Microstructure of Barite Aggregate from Different Deposits Using X-Ray Microtomography and Optical Microscopy
Autorzy:
Żołek, N.
Ranachowski, Z.
Ranachowski, P.
Jóźwiak-Niedźwiedzka, D.
Kudela, S. jr.
Dvorak, T.
Powiązania:
https://bibliotekanauki.pl/articles/351890.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
barite ore
barite aggregate
microstructure
optical microscopy
thin sections analysis
X-ray tomography
Opis:
Two different barite ore (barium sulfate BaSO4) specimens from different localizations were tested and described in this paper. Analysis of the microstructure was performed on polished sections, and on thin sections using X-ray microtomography (micro-CT), and optical microscopy (MO). Microtomography allowed obtaining three-dimensional images of the barite aggregate specimens. In the tomograms, the spatial distribution of the other polluting phases, empty space as well as cracks, pores, and voids – that exceeded ten micrometers of diameter-were possible to visualize. Also, the micro-CT allowed distinguishing between minerals of different density, like SiO2 and BaSO4. Images obtained and analyzed on thin sections with various methods using the optical microscopy in transmitted light delivered additional information on the aggregate microstructure, i.e. allow for estimation of the different kinds of inclusions (like the different density of the minerals) in the investigated specimens. Above methods, which were used in the tests, completed each another in order to supply a set of information on inclusions’ distribution and to present the important differences of the barite aggregate specimens microstructure.
Źródło:
Archives of Metallurgy and Materials; 2017, 62, 2A; 697-702
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Determination Of Diffusive Tortuosity In Concrete Specimens Using X-Ray Microtomography
Wyznaczanie krętości dyfuzyjnej w próbkach betonów przy zastosowaniu metody mikrotomografii rentgenowskiej
Autorzy:
Ranachowski, Z.
Jóźwiak-Niedźwiedzka, D.
Ranachowski, P.
Dąbrowski, M.
Kudela Jr., S.
Dvorak, T.
Powiązania:
https://bibliotekanauki.pl/articles/354949.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
X-ray tomography
concrete microstructure
diffusive tortuosity
tomografia rentgenowska
mikrostruktura betonu
krętość dyfuzyjna
Opis:
The paper presents a method of pore connectivity analysis applied to specimens of cement based composites differing in water to cement ratio. The method employed X-ray microtomography (micro-CT). Microtomography supplied digitized three-dimensional radiographs of small concrete specimens. The data derived from the radiographs were applied as an input into the application based on the algorithm called ‘random walk simulation’. As the result a parameter called diffusive tortuosity was established and compared with estimated porosity of examined specimens.
Artykuł prezentuje metodę wyznaczania parametru charakteryzującego intensywność połączeń mikroporów w zastosowaniu do próbek kompozytów z matrycą cementową, różniących się stosunkiem wodnocementowym. Metoda bazuje na wynikach badań z zastosowaniem mikrotomografii rentgenowskiej. Analizowano zdigitizowane zestawy danych, opisujące trójwymiarową reprezentację mikrostruktury niewielkich próbek wykonanych z betonu. Przygotowane w ten sposób skany mikrostruktury zastosowano jako dane wejściowe wprowadzone do oprogramowania wykorzystujacego algorytm ‘przypadkowo migrujących cząstek wirtualnych’. W ten sposób wyznaczono parametr mikrostruktury znany jako krętość dyfuzyjna. Parametr ten porównano z porowatością obserwowaną wyznaczoną dla zbadanych próbek przy wykorzystaniu analizy jasności voxeli w analizowanych próbkach.
Źródło:
Archives of Metallurgy and Materials; 2015, 60, 2A; 1115-1119
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Casting pore characterization by X-ray computed tomography and metallography
Charakteryzacja porów odlewniczych metodami rentgenowskiej tomografii komputerowej i metalografii
Autorzy:
Fintová, S.
Anzelotti, G.
Konečná, R.
Nicoletto, G.
Powiązania:
https://bibliotekanauki.pl/articles/139863.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
zmęczenie
techniki metalograficzne
stopy Al-Si
tomografia rentgenowska
fatigue
metallographic techniques
Al-Si alloy
X-ray tomography
Opis:
Casting porosity is the main factor influencing the fatigue properties of Al-Si alloys. Due to the increasing use of aluminum castings, porosity characterization is useful for estimating their fatigue strength. In principle, a combination of metallographic techniques and statistical pore analysis is a suitable approach for predicting the largest defect size that is critical for the casting. Here, the influence of modifiers and casting technology on the largest pore size population in AISi7Mg alloy specimens is obtained and discussed adopting the Murakami's approach. However, porosity evaluation is a challenge in the case of microshrinkage pores, which are frequently found in industrial castings. Their complicated morphology prevents a reliable definition of an equivalent defect size based on metallographic techniques. This contribution reports the application of X-ray tomography to the 3D reconstruction of real pores in cast Al-Si alloys and provides insight into the complication of microshrinkage pore sizing by metallography.
Porowatość odlewów jest głównym czynnikiem wpływającym na właściwości wytrzymałościowe stopów Al-Si. Z uwagi na rosnące zastosowanie odlewów aluminiowych, charakteryzacja ich porowatości nabiera znaczenia dla oceny wytrzymałości zmęczeniowej. Uważa się, że właściwym podejściem jest zastosowanie kombinacji technik metalograficznych i statystycznej analizy porów, co umożliwia przewidywanie największego, krytycznego dla odlewu, rozmiaru defektów. W tej pracy wyznaczano i dyskutowano wpływ modyfikatorów i technologii odlewania na największy rozmiar populacji porów w próbkach stopu AlSi7Mg, przyjmując podejście Mirakami'ego. Ocena porowatości staje się jednak wyzwaniem w przypadku porów związanych z. mikrokurczliwością, które występują często w odlewach przemysłowych. Ich skomplikowana morfologia powoduje, że trudno jest wiarygodnie zdefiniować równoważny rozmiar defektu w oparciu o techniki metalograficzne. Przedstawione doniesienie zawiera opis zastosowania rentgenowskiej tomografii komputerowej do trójwymiarowej rekonstrukcji rzeczywistych porów w odlewie ze stopu AISi i daje pogląd na temat komplikacji w wymiarowaniu porów związanych z mikrokurczliwością metodami metalograficznymi.
Źródło:
Archive of Mechanical Engineering; 2010, LVII, 3; 263-273
0004-0738
Pojawia się w:
Archive of Mechanical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Three Dimensional Morphology of β-Al5FeSi Intermetallics in AlSi Alloys
Autorzy:
Mikołajczak, P.
Ratke, L.
Powiązania:
https://bibliotekanauki.pl/articles/383272.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
aluminum alloy
intermetallics
β-Al5FeSi
X-ray tomography
morphology
solidification
stop aluminium
intermetalik
tomografia rentgenowska
Opis:
Iron is the most common and detrimental impurity in casting alloys and has been associated with many defects. The main consequence of the presence or adding of iron to AlSi alloys is the formation Fe-rich intermetallics with especially deleterious β-Al5FeSi. β-Al5FeSi phases are most often called needles on 2D micro sections, whilst platelets in 3D geometry. The x-ray tomography results have demonstrated Fe-rich phases with shapes different from simple forms such as needles or platelets and presented bent and branched phases. β grown as complicated structure of bent and branched intermetallics can decrease feeding ability, strengthen pores nucleation and eutectic colonies nucleation leading to lower permeability of mushy zone and porosity in the castings.
Źródło:
Archives of Foundry Engineering; 2015, 15, 1; 47-50
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study on the State of Internal Stress and Strain of TATB-based Polymer Bonded Explosive Using Strain Markers and Cone-Beam Computed Tomography
Autorzy:
Dai, B.
Lan, L.-G.
Zhang, W.-B.
Tian, Y.
Powiązania:
https://bibliotekanauki.pl/articles/358613.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Przemysłu Organicznego
Tematy:
technology of materials
testing and analysis
compression molding
polymer bonded explosive
stress state
strain ellipsoid
X-ray tomography
Opis:
Precise measurement of the inner structural strain of polymer bonded explosive (PBXs) granules during compression molding is highly desirable in order to investigate the inner stress distribution field and its underlying generation mechanism, with the aim of improving the stress distribution uniformity. In this contribution, TATB-based (1,3,5-triamino-2,4,6-trinitrobenzene) PBX granules were formulated and the stress-strain state of the PBX granules during the warm molding process was analyzed. Strain markers were implanted at different locations and the deformation characteristics and regularity of the embedded spherical strain markers were obtained by X-ray micro-tomography. Thus the local strain states at different locations could be obtained, and the local stress state could be deduced. The results showed that axisymmetric deformation occurred in all of the strain markers, where the flat strain ellipsoids were mainly compressed uni-axially. In the central region, the stress was mainly in an axial direction, and the shear force was small. Not only axial stresses, but also large shear stresses in the surrounding region of the cylindrical grains were present. The stress gradient in the central region was greater than that in the surrounding region. The stress was greater in the surrounding region because this region was squeezed by the mold. The maximum strain degree was 44.8% larger than the minimum strain degree. The local stress increment in each region was quantified. The stress increments of the three axes were in the range 14.2-19.5 MPa. This study examined the feasibility of evaluating the inner stress–strain state of PBX granules in a quantitative manner, which is significant in determining the inner strain and stress distribution in PBX granules during the molding process.
Źródło:
Central European Journal of Energetic Materials; 2017, 14, 3; 688-707
1733-7178
Pojawia się w:
Central European Journal of Energetic Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
K-means clustering in textured image: example of lamellar microstructure in titanium alloys
Klasteryzacja k-średnich obrazów teksturowych lamelarnych mikrostruktur stopów tytanu
Autorzy:
Al Darwich, R.
Babout, L.
Strzecha, K.
Powiązania:
https://bibliotekanauki.pl/articles/407821.pdf
Data publikacji:
2017
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
k-means clustering
oriented textured
number of cluster
X-ray tomography
klasteryzacja k-średnich
tekstura zorientowana
liczba klastrów
tomografia rentgenowska
Opis:
This paper presents an implementation of the k-means clustering method, to segment cross sections of X-ray micro tomographic images of lamellar Titanium alloys. It proposes an approach for estimating the optimal number of clusters by analyzing the histogram of the local orientation map of the image and the choice of the cluster centroids used to initialize k-means. This is compared with the classical method considering random coordinates of the clusters.
W artykule przedstawiono implementację metody klasteryzacji k-średnich, do segmentacji dwuwymiarowych rentgenowskich obrazów mikro tomograficznych lamelarnych stopów tytanu. Zaproponowano metody szacowania optymalnej liczbę klastrów oraz wyboru centro idów poprzez analizę histogramu mapy lokalnych kierunków obrazu. Dokonano porównania zaproponowanych metod z losowym doborem początkowego położenia klastrów.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2017, 7, 3; 43-46
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
X-ray tomography investigation of Fe-rich intermetallics in AlSi alloys
Autorzy:
Mikołajczak, P.
Ratke, L.
Powiązania:
https://bibliotekanauki.pl/articles/381463.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
aluminum alloy
intermetallics
β-Al5FeSi
X-ray tomography
melt flow
stop aluminium
związek międzymetaliczny
tomografia rentgenowska
szybkość przepływu
Opis:
Iron exists as a common impurity element in AlSi foundry alloys. The main consequence of the presence or adding of iron to AlSi alloys is the formation Fe-rich intermetallics with especially deleterious β-Al5FeSi. This work aims to identify the role of fluid flow on the microstructure and intermetallics in Al-9 wt.% Si-0.2/0.5/1.0 wt.% Fe alloys directionally solidified under defined thermal and fluid flow conditions and extensively uses 3D x-ray tomography to get a better insight into their morphology and formation. The results have revealed the growth of larger and more dense β-Al5FeSi intermetallics in the specimen centre as an effect of forced flow. The reconstructions confirmed that the course of number density at the specimen cross section increases from the specimen edge to its centre.
Źródło:
Archives of Foundry Engineering; 2013, 13, 4; 79-82
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Shape accuracy in single point incremental forming of conical frustums from titanium CP2 sheets
Dokładność kształtu w jednopunktowym kształtowaniu przyrostowym stożków ściętych z blach tytanowych CP2
Autorzy:
Szpunar, Marcin
Balcerzak, Maciej
Żaba, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/2204384.pdf
Data publikacji:
2022
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
incremental sheet forming
titanium
springback
optical forming analysis
X-ray tomography
kształtowanie przyrostowe blach
tytan
sprężynowanie
analizy optyczne kształtowania
tomografia komputerowa
Opis:
This paper presents frustum cone drawpiece analysis made of titanium CP2 sheet by a single incremental sheet forming. Central composite design has been adopted to carry out an experiment containing 20 runs, then multi-criteria parameter optimization has been done. Optimal parameters have been validated and responses deviations do not exceed 4% compared to created models. For the drawpiece formed with optimal parameters, AGRUS optical measurement and X-ray tomography has been applied to check the obtained of the part wall thickness and general deviations compared to the CAD model. The wall angle discrepancy of the cone generatrix has also been analyzed. No gaps or ruptures have been confirmed by X-ray. The blank rolling direction has a significant effect on the drawpiece deviations. The measurement results showed deviations of the drawpiece wall angle +0.27°/- 0.06°, sheet thickness on the cone +0.012/-0.04 mm and +0.151/-0.096 mm from the reference CAD geometry.
W pracy przedstawiono analizę wytłoczek w kształcie stożka ściętego wykonanego z blachy tytanowej CP2 metodą jednopunktowego przyrostowego kształtowania. Do przeprowadzenia eksperymentu obejmującego 20 przebiegów przyjęto centralny plan kompozycyjny, następnie dokonano wielokryterialnej optymalizacji parametrów. Dokonano walidacji optymalnych parametrów, a uzyskane wyniki nie przekraczają 4% w odniesieniu do stworzonych modeli. Dla wytłoczki uformowanej z optymalnymi parametrami zastosowano pomiar optyczny AGRUS oraz tomografię rentgenowską w celu sprawdzenia uzyskanej grubości ścianki wytłoczki i odchyłek w porównaniu z modelem CAD. Przeanalizowano również rozbieżność kątów ścian tworzących stożka. Za pomocą skanu rentgenowskiego potwierdzono brak szczelin i pęknięć wytłoczki. Kierunek walcowania półfabrykatu ma istotny wpływ na odchyłki. Wyniki pomiarów wykazały odchylenia kąta ścianki wytłoczki +0,27/-0,06°, grubości ścianki na stożku +0.012/-0.04 mm oraz +0.151/-0.096 mm od geometrii referencyjnej CAD.
Źródło:
Zeszyty Naukowe Politechniki Rzeszowskiej. Mechanika; 2022, z. 94; 63--75
0209-2689
2300-5211
Pojawia się w:
Zeszyty Naukowe Politechniki Rzeszowskiej. Mechanika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of X-Ray Microtomography and Optical Microscopy to Determine the Microstructure of Concrete Penetrated by Carbon Dioxide
Zastosowanie mikrotomografii komputerowej i mikroskopii optycznej do oceny mikrostruktury betonów poddanych działaniu CO2
Autorzy:
Ranachowski, Z.
Jóźwiak-Niedźwiedzka, D.
Ranachowski, P.
Rejmund, F.
Dąbrowski, M.
Kudela, S. jr.
Dvorak, T.
Powiązania:
https://bibliotekanauki.pl/articles/351864.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cement-matrix composites
concrete deterioration
X-ray tomography
microscopic analysis
concrete microstructure
kompozyty cementowe
zniszczenie betonu
tomografia rentgenowska
analiza mikroskopowa
mikrostruktura betonu
Opis:
In the paper two advanced methods for testing cement based composites are described and compared. These are X-ray microtomography and optical microscopy. Microtomography supplies three-dimensional images of small concrete specimens. In the tomograms all cracks, pores and other voids and inclusions, that exceed a few micrometers, are shown. Such visualisation can become a valuable tool for analysis of the basic material properties. Images obtained on thin sections and analysed with various methods on optical microscopes supply additional information on material microstructure that cannot be obtained in tomograms. For example it is relatively easy to determine zone penetrated by CO2 ingress. These two methods, presented on examples of tests, complete each another in order to supply a set of information on composition and defects of tested composite materials.
W artykule przedstawiono dwie nowoczesne metody analizy struktury materiałów kompozytowych ze spoiwem na bazie cementu. Są to mikrotomografia komputerowa oraz optyczna analiza cienkich szlifów. Mikrotomografia pozwala na uzyskanie trójwymiarowych obrazów niewielkich próbek betonowych. Na tomogramach widoczne są układy rys, porów i innych pustek, których wymiary przekraczają kilka mikrometrów. Przestawienie tych obiektów w przestrzeni jest ważnym narzędziem do analizy podstawowych właściwosci materiału. Obrazy uzyskane na cienkich szlifach w mikroskopie optycznym, analizowane następnie różnymi metodami, dostarczają dodatkowych informacji o mikrostrukturze materiału, które nie mogą być dostrzeżone na tomogramach. Stosunkowo łatwo jest np. uzyskac obrazy stref skarbonatyzowanej matrycy cementowej. Obie przedstawione metody uzupełniają się wzajemnie i pozwalają na otrzymanie zbioru informacji o składzie i defektach badanych materiałów kompozytowych.
Źródło:
Archives of Metallurgy and Materials; 2014, 59, 4; 1441-1447
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies