Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Kaczmarek, K." wg kryterium: Autor


Wyświetlanie 1-3 z 3
Tytuł:
Vanadium oxide rich nanotubes on both phases of anodized Ti6Al4V alloy
Autorzy:
Kaczmarek, A.
Arkusz, K.
Krasicka-Cydzik, E.
Powiązania:
https://bibliotekanauki.pl/articles/284438.pdf
Data publikacji:
2012
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
nanotubes
Ti6Al4V alloy
implants
Opis:
Ti6Al4V, if used as an implant material is becoming replaced by other titanium based medical alloys due to the toxicity of vanadium. Anodic modification carried out to obtain nanoporous structures on this two-phase material leads to the formation of oxides only over а phase, vanadium rich ß phase oxide being etched [1,2] due to the high solubility of V-oxides. However, vanadium oxides having excellent conductive [3,4] and catalytic [5] properties, with ability to bind proteins [6] and similar to phosphates in the metabolic affinity to insulin mimics [7]. Such properties are prospective for using anodised nanotubular layer of the Ti6Al4V as a biosensor platform. Anodizing the Ti6Al4V alloy in phosphoric acid with fluoride ions gives nanotubes presented in Fig.1a, whereas using 99.0% ethylene glycol with 0.6% fluorides leads to formation of uniform 50nm diameter nanotubes on both phases Fig. 1b. To next experiments for thermal modification and electrochemical examination the most appropriate surface was obtained during anodization in 99% ethylene glycol with 0.6% of NH4F in 20V during 20min. Thermal modification was carried in 600PC in three atmospheres (air, argon and nitrogen), only modification in nitrogen does not affect on the nanotubes morphology, in other cases shape and nanotubular character of oxide layer changes to nonregular oxide structures. Corrosion potential, cyclic voltametry and EIS studies carried in PBS solution for each of thermally modified oxide surface confirmed unique electric properties of obtained layers. Obtained novel coating with nanotubular TiO2, Al2O3, and VOX and their conductive, biological and catalytic properties may be a bioactive and cell growth stimulating layer, a platform for high sensitive sensors, or nanodimensional electrode material.
Źródło:
Engineering of Biomaterials; 2012, 15, no. 116-117 spec. iss.; 155
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Deposition of various gradient multilayer coatings on Ti-6Al-4V alloy using MW CVD methods for orthopaedic implants
Autorzy:
Kyzioł, K.
Oczkowska, J.
Klich, M.
Kaczmarek, Ł.
Kyzioł, A.
Powiązania:
https://bibliotekanauki.pl/articles/283831.pdf
Data publikacji:
2017
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
Ti6Al4V alloy
coatings
orthopaedic implants
Źródło:
Engineering of Biomaterials; 2017, 20, no. 143 spec. iss.; 26
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Corrosion resistance of Ti6Al4V alloy coated with caprolactone-based biodegradable polymeric coatings
Odporność korozyjna stopu Ti6Al4V pokrytego biodegradowalnymi powłokami polimerowymi na bazie kaprolaktonu
Autorzy:
Kajzer, W.
Jaworska, J.
Jelonek, K.
Szewczenko, J.
Kajzer, A.
Nowińska, K.
Hercog, A.
Kaczmarek, M.
Kasperczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/1365372.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
corrosion resistance
metal biomaterials
Ti6Al4V alloy
biodegradable polymeric coatings
odporność korozyjna
biomateriały metalowe
stop Ti6Al4V
biodegradowalne powłoki polimerowe
Opis:
The aim of this study was to determine the influence of long-term exposure of Ringer’s solution on degradation of the anodically oxidated Ti6Al4V alloy coated with a biodegradable polymer coating. Polymeric coatings made of poly(glycolide-ε-caprolactone) – G-Cap and poly(glycolide- ε-caprolactone-lactide) – G-Cap-L were applied by a dip-coating method. Degradation was assessed on the basis of the results of pitting corrosion resistance and density of metal ions infiltrating to the solution. Studies were conducted for samples after 3, 6, 8, 10 and 12 weeks of exposure to the corrosive environment. In addition, topography of the surface of the polymer coating was assessed. As a result of potentiodynamic studies, the value of the polarization resistance and corrosion potential for the G-Cap and G-Cap-L coated samples were significantly decreased while simultaneous reduction of the density of metal ions infiltrating to the solution throughout the whole study period. There was also observed a faster degradation of the G-Cap coating compared to G-Cap-L, which showed local discontinuity after 12 weeks of exposure. The obtained results provide the basis for the development of polymeric coatings on surface of metal implants with predictable time / kinetics of degradation by selecting the composition of polymers while simultaneous limitation of metal ions infiltration into surrounding tissues.
Celem pracy było określenie wpływu długotrwałego oddziaływania rozworu Ringera na proces degradacji utlenianego anodowo stopu Ti6Al4V pokrytego powłoką biodegradowalnego polimeru. Powłoki polimerowe wykonane z poli(glikolido- ε-kaprolaktonu) – G-Cap oraz poli(glikolido ε-kaprolaktono- laktydu) – G-Cap-L naniesiono metodą zanurzeniową (dip-coating). Proces degradacji w funkcji czasu oceniano na podstawie wyników badań odporności na korozję wżerową oraz gęstości masy jonów metalowych przenikających do roztworu. Badania przeprowadzono dla próbek po 3, 6, 8, 10 i 12 tygodniach ekspozycji na środowisko korozyjne. Ponadto oceniano topografię powierzchni powłoki polimerowej. W wyniku przeprowadzonych badań potencjodynamicznych stwierdzono wyraźne obniżenie wartości oporu polaryzacyjnego i potencjału korozyjnego dla próbek z naniesionymi powłokami G-Cap i G-Cap-L przy jednoczesnym wyraźnym ograniczeniu gęstości jonów metalowych przenikających do roztworu w całym okresie badawczym. Stwierdzono również szybszą degradację powłoki typu G-Cap w porównaniu do G-Cap-L, dla której po 12 tygodniu ekspozycji stwierdzono lokalnie występujące przerwania ciągłości. Uzyskane wyniki dają podstawę do opracowywania na powierzchni implantów metalowych powłok polimerowych o przewidywalnym czasie/określonej kinetyce degradacji, poprzez dobór składu polimerów z jednoczesnym ograniczeniem możliwości przenikania jonów metalowych do otaczających tkanek.
Źródło:
Eksploatacja i Niezawodność; 2018, 20, 1; 30-38
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies