Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Kadhim, K. J." wg kryterium: Autor


Wyświetlanie 1-1 z 1
Tytuł:
Experimental investigation of the effect of damping coefficients on spring diameter thickness
Autorzy:
Kadhim, K. J.
Powiązania:
https://bibliotekanauki.pl/articles/2201068.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Komputerowej Nauki o Materiałach i Inżynierii Powierzchni w Gliwicach
Tematy:
process parameter
RSM analysis
damping force
test machine
parametr procesu
analiza RSM
optymalizacja
siła tłumienia
urządzenie badawcze
Opis:
Purpose The main objective of this research is to study the effect of damping coefficients on the damping strength of shock absorbers using Taguchi Design Experiment (DOE) and rough surface method in Design Expert 7.0.0. Design/methodology/approach To achieve and measure the damping force based on the data analysis in the design program. The effecting parameters are: damping diameter (A), gas pressure nitrogen in damping (B), and suspension velocity(C). Consequently, the experiment was carried out in the lab to measure the damping force based on the data analysis. Findings The experimental results demonstrated that nitrogen gas at a pressure of 40 bars is appropriate for dealing with motorcycles and that optimum parameter values may be achieved using ANOVA (Analysis of Variance), regression analysis, and confirmation studies. Research limitations/implications The measure of the damping force in this process widely depend on the technical specifications of a testing machine. Consequently, machine operating parameters consider the main limiting factor in this process. Practical implications In this current work, a steel spring of (50) mm diameter has been used in this experimental investigation to measure the influence of the damping force based on the data analysis. In addition, optimal working parameter values that maximize the performance were identified. The experimental test was planned and conducted according to the ANOVA (Analysis of Variance). Originality/value The validation of experimental results shows that this analysis gives an average error 5%, it’s also concluded that the gas at a pressure of 40 bars is appropriate for dealing with motorcycles and can be adopted safely.
Źródło:
Journal of Achievements in Materials and Manufacturing Engineering; 2022, 115, 1; 16--25
1734-8412
Pojawia się w:
Journal of Achievements in Materials and Manufacturing Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-1 z 1

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies