Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "fault tolerant control (FTC)" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Fault tolerant control of a PMSM drive in the selected emergency conditions
Autorzy:
Siembab, K.
Powiązania:
https://bibliotekanauki.pl/articles/376452.pdf
Data publikacji:
2013
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
PMSM
PMSM drive
fault-tolerant inverter
FTC
Fault Tolerant Control
Opis:
The paper describes an investigation of fault tolerant control strategies for permanent magnet synchronous motor (PMSM) driven by a fault-tolerant inverter. The inverter is a topology-modified inverter with fault-tolerant capability, which can be configured as the standard 3-phase 6-switch inverter and reconfigured as 3-phase 4-switch or 2-phase 4-switch inverter under the fault condition. By analyzing operating principle of a fault-tolerant inverter and the mathematical model of PMSM, fault tolerant control algorithms are investigated. There is a conclusion that three phase stator windings of PMSM can be effectively operated by controlling only two phase currents. Simulation results show the validity of the proposed methods.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2013, 75; 165-172
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Universal System for Detection and Compensation of Current Sensor Faults in Three-Phase Power Electronic Systems
Autorzy:
Dybkowski, Mateusz
Jankowska, Kamila Anna
Powiązania:
https://bibliotekanauki.pl/articles/2175934.pdf
Data publikacji:
2022
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
FTC
fault-tolerant control system
active rectifier
current sensor
PMSM
permanent magnet synchronous motor
IM
induction motor
diagnostics
Opis:
The article discusses the universal current sensor fault detection and compensation mechanism, which can be applied in three-phase power electronics (PE) symmetrical system. The mechanism is based on the assumption that a symmetrical system can be described using different components in the stationary reference frame. The solution given in article as a Cri-base detector was tested in electrical drives with induction motors (IMs) and permanent magnet synchronous motors (PMSMs). This study also proves that the same algorithm can work stable in active rectifier systems. Such an application of this detector has not been previously reported in the literature. The article describes the detection of various types of faults in different phases. The fault-tolerant voltage-oriented control (FTVOC) of an active rectifier is compared with previously described solutions for IMs and PMSMs. By analysing in various types of systems, the work proves the universality of the detector based on Cri markers.
Źródło:
Power Electronics and Drives; 2022, 7, 42; 267--278
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies