Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "water exchange" wg kryterium: Temat


Wyświetlanie 1-5 z 5
Tytuł:
Laser Granulometer as an Useful Tool for Selection of Appropriate Membranes Used in the MIEX®DOC-UF/MF Hybrid Process
Autorzy:
Rajca, M.
Bray, R. T.
Fitobór, K.
Gołombek, K.
Powiązania:
https://bibliotekanauki.pl/articles/354202.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ion exchange
MIEX® resin
water treatment
ultrafiltration
microfiltration
laser granulometer
SEM
Opis:
In the study, particle size distribution of the MIEX® resin was presented. Such analyses enable to determinate whether presence of fine resin fraction may be the reason for unfavorable membrane blocking during water purification by the hybrid MIEX®DOC – microfiltration/ultrafiltration systems. Granulometric analysis of resin grains using the laser diffraction particle size analyzer (laser granulometer) was carried out as well as the microscopic analysis with scanning electron microscope. The following samples were analyzed: samples of fresh resin (a fresh resin – not used in water treatment processes) and samples of repeatedly used/regenerated resin that were collected to analysis during mixing and after sedimentation process. Particle size distribution was slightly different for fresh resin and for repeatedly used/regenerated resin. The grains sizes of fresh resin reached approximately 60 μm (d10), 120 μm (d50) and 220 μm (d90). Whereas the sizes of repeatedly used/regenerated resin were about 15 μm (d10), 40 μm (d50) and 115-130 μm (d90). The smallest resin grains sizes were in the range of 0.3-0.45 μm. This ensures that the ultrafiltration membranes retain all resin grains, even the smallest ones. Whereas the microfiltration membranes must be appropriately selected to guarantee full separation of the resin grains and at the same time to exclude a membrane pores blocking.
Źródło:
Archives of Metallurgy and Materials; 2018, 63, 3; 1133-1140
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie testów naczyniowych do oceny skuteczności usuwania substancji organicznych z wody w procesie MIEX®DOC
Application of jar tests to estimating the efficiency of organic substances removal in the MIEX®DOC water treatment process
Autorzy:
Mołczan, M.
Biłyk, A.
Slunjski, M.
Celer, K.
Powiązania:
https://bibliotekanauki.pl/articles/236804.pdf
Data publikacji:
2005
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczanie wody
substancje organiczne
żywica MIEX
wymiana jonowa
water treatment
organics removal
MIEX® resin
ion exchange
Opis:
Usunięcie związków organicznych do jak niższego poziomu z wody przeznaczonej do spożycia staje się coraz pilniejszym zadaniem technologicznym, głównie z uwagi na tworzenie ubocznych produktów dezynfekcji. Obok klasycznych procesów jednostkowych oczyszczania wody, bardzo obiecująca jest nowa technologia MIEX®DOC, zaproponowana przez firmę Orica Watercare, polegająca na zastosowaniu namagnetyzowanych żywic anionowymiennych do usuwania substancji organicznych z wody. W pracy przedstawiono wyniki standardowych testów oczyszczania wody, tj. kinetycznego, symulacyjnego oraz koagulacji, na przykładzie wody powierzchniowej (Oława), ujmowanej na potrzeby Zakładu Produkcji Wody "Mokry Dwór" we Wrocławiu. Uzyskane wyniki pozwoliły na wstępną ocenę przydatności nowej metody do oczyszczania badanej wody, a także na zaplanowanie badań pilotowych, w tym ustalenie zakresów czasu kontaktu, stężenia oraz krotności wymian objętości żywicy. Stwierdzono, że proces MIEX®DOC jest skuteczniejszy w usuwaniu organicznych domieszek wody niż koagulacja. Jego zastosowanie pozwoli na obniżenie dawki koagulantu do minimum wynikającego z potrzeby klarowania wody. Zoptymalizowanie współdziałania procesów wymiany jonowej oraz koagulacji pozwoli na obniżenie oraz ustabilizowanie poziomu zanieczyszczenia organicznego badanej wody, co korzystnie wpłynie na pracę złóż sorpcyjnych, tworząc warunki do wydłużenia cyklu ich pracy.
The need of reducing the organic matter content in potable water to the lowest possible level has taken on a sense of urgency in technological terms, mainly due to the formation of disinfection by-products. The magnetized anion exchange resin (MIEX®) developed by Orica Watercare shows great promise for the removal of organic matter from water, when compared to classical water treatment processes. This paper shows the results of standard MIEX®DOC laboratory tests, such as kinetic, simulation and coagulation tests performed on the river water taken in for the Water Treatment Plant of Wrocław (Mokry Dwór). With the results obtained it was possible to estimate the main parameters of the overall MIEX®DOC process, such as contact time, resin concentration, and resin bed volume. On average, the MIEX®DOC process yielded a much higher DOC removal, and much lower UV absorption, as compared to standard coagulation with PAX-18. Another series of experiments was carried out to study a sequence MIEX®DOC followed by coagulation. It was found that this setup allowed the coagulant dose to be lowered to the level typical of standard turbidity removal, since the MIEX®DOC process did not remove turbidity from the tested water.
Źródło:
Ochrona Środowiska; 2005, R. 27, nr 2, 2; 3-7
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania pilotowe skuteczności oczyszczania wody w procesie MIEX®DOC
Pilot Investigations into the MIEX®DOC Process
Autorzy:
Mołczan, M.
Biłyk, A.
Slunjski, M.
Siciński, T.
Stróż, J.
Powiązania:
https://bibliotekanauki.pl/articles/237215.pdf
Data publikacji:
2005
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczanie wody
usuwanie substancji organicznych
wymiana jonowa
żywica MIEX
water treatment
organics removalion exchange
MIEX® resin
Opis:
Usunięcie związków organicznych z wody przeznaczonej do spożycia do jak najniższego poziomu staje się coraz pilniejszym zadaniem technologicznym, głównie z uwagi na tworzenie ubocznych produktów dezynfekcji. Obok klasycznych procesów jednostkowych, duże nadzieje stwarza nowa technologia MIEX®DOC, oparta na procesie wymiany jonowej na namagnetyzowanych żywicach anionowymiennych. Ocena przydatności tej metody wymaga w pierwszej kolejności wykonania badań technologicznych w postaci testów naczyniowych, a następnie badań pilotowych procesu. W pracy zaprezentowano wyniki badań pilotowych przeprowadzonych w marcu 2005 r. w oparciu o wodę powierzchniową z rzeki Oławy, ujmowaną na potrzeby zakładu oczyszczania wody "Mokry Dwór" we Wrocławiu. Zwrócono szczególną uwagę na zasadnicze reguły prowadzenia takich badań oraz na podstawowe parametry procesowe, jak czas kontaktu, zawartość żywicy w układzie oraz krotność wymiany objętości żywicy. Umiejętne operowanie wartościami tych parametrów pozwoliło na kształtowanie poziomu zanieczyszczenia organicznego wody oczyszczonej. Badania potwierdziły uzyskane wcześniej w testach naczyniowych dane o efektach usuwania domieszek organicznych z wody w procesie MIEX®DOC, lokując je na poziomie 50-60% usunięcia dla takich wskaźników jak barwy i absorbancja w UV oraz 40% dla rozpuszczonego węgla organicznego. Badania nie potwierdziły natomiast wniosków dotyczących nieskuteczności koagulacji w usuwaniu substancji organicznych z wody poddanej procesowi MIEX®DOC. Koagulacja, jako proces samodzielny, była zdecydowanie mniej skuteczna w usuwaniu zanieczyszczeń organicznych, niemniej w połączeniu z wymianą jonową umożliwia zwiększenie stopnia usunięcia rozpuszczonego węgla organicznego z 40% nawet do około 60%. Wykazano, że nie wyczerpuje to puli związków organicznych podatnych na usuwanie w innych procesach, jak np. sorpcji na węglu aktywnym.
From the technological viewpoint, the removal of organic compounds to the lowest possible level from water treated for drinking purposes has taken on a sense of urgency, mainly due to the formation of disinfection by-products. Apart from the conventional unit processes, the new MIEX®DOC technology, which is based on the process of ion exchange on magnetized anion-exchange resins, seems to be very promising. To assess the applicability of this method to the purpose of interest, it is necessary to perform technological investigations using jar tests, followed by pilot investigations of the process. This paper includes the results of a pilot study carried out in March 2005 with samples of surface water (from the river Oława) taken in by the Waterworks Mokry Dwór of Wrocław. Particular consideration was given to the specific rules governing this type of study, as well as to the basic process parameters of the process (contact time, resin content in the system, bed volumes). Owing to a reasonable adoption of the parameter values, it is possible to control the levels of organic pollutants in the treated water. The pilot study has substantiated the jar-test data on the efficiency of organic matter removal from water by the MIEX®DOC process, setting it at the level of 50 to 60% for such pollutants as color and UV absorbance, and at the level of 40% for dissolved organic carbon (DOC). The study has not confirmed the conclusion that coagulation fails to be efficient in removing organic substances from water treated by the MIEX®DOC mode. Coagulation alone was found to be remarkably less efficient in removing organic pollutants. However, combined with ion exchange, the coagulation process accounted for a rise in the extent of DOC removal from 40% to about 60%. It was shown that this did not mean a decline in the amount of organic compounds easy to remove via other processes, e.g. sorption on activated carbon.
Źródło:
Ochrona Środowiska; 2005, R. 27, nr 4, 4; 19-26
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ dawki żywicy i czasu kontaktu na skuteczność usuwania zanieczyszczeń organicznych z wody w procesie MIEX®DOC
Effect of resin dosage and contact time on organic matter removal from water by the MIEX®DOC process
Autorzy:
Mołczan, M.
Powiązania:
https://bibliotekanauki.pl/articles/236404.pdf
Data publikacji:
2006
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczanie wody
usuwanie substancji organicznych
wymiana jonowa
żywica MIEX
dawka żywicy
czas kontaktu
water treatment
organics removal
ion exchange kinetics
MIEX® resin
resin dosage
contact time
Opis:
Żywica anionowymienna MIEX® jest materiałem służącym między innymi do usuwania związków organicznych z roztworów wodnych. Kinetyka reakcji wymiany anionowych form RWO na jony chlorkowe z żywicy, opisana parametrami dawki żywicy i czasu kontaktu, jest podstawą działania procesu MIEX DOC. W pracy wykazano ścisły związek pomiędzy skutecznością usuwania zanieczyszczeń organicznych z wody a parametrami kinetyki procesu, w postaci zależności skuteczności procesu od iloczynu dawki żywicy i czasu jej kontaktu z oczyszczaną wodą. Zaobserwowana prawidłowość pozwala na zdefiniowanie obszaru stosowalności procesu MIEX DOC, co ma istotne znaczenie praktyczne, zarówno w aspekcie projektowania jak i eksploatacji tego procesu. W odniesieniu do badanej wody racjonalne stosowanie metody anionowymiennej wymaga użycia takich wartości dawki żywicy i czasu kontaktu, aby ich iloczyn mieścił się w przedziale 75 ÷ 200 min cm3/dm3.
Besides other uses, the anion-exchange resin MIEX® is also designed to remove organic compounds from aqueous solutions. The kinetics governing the exchange of the DOC anions for the chloride ions of the MIEX® resin (described by the resin parameters and contact time) is the basic mechanism involved in the MIEX®DOC process. Our study has shown a close relationship between the efficiency of organic matter removal and the parameters of the process kinetics. In the formula that describes this finding, the efficiency of the process is related to the product of resin dose and its time of contact with the water to be treated. By virtue of such relationship, it is possible to define the range of applicability for the MIEX®DOC process. As for the water used in this study, the application of the anion exchange method was found to be rational when the product of the resin dose value and contact time value ranged between 75 and 200 min x cm3/dm3.
Źródło:
Ochrona Środowiska; 2006, R. 28, nr 3, 3; 35-38
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Skuteczność usuwania rozpuszczonych związków organicznych z wody o małej wartości absorbancji właściwej na żywicy anionowymiennej MIEX®Gold
Removal efficacy of dissolved organic compounds with low specific absorbance value from water by an anion-exchange resin MIEX®Gold
Autorzy:
Mołczan, M.
Wolska, M.
Powiązania:
https://bibliotekanauki.pl/articles/237412.pdf
Data publikacji:
2016
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczanie wody
związki organiczne
wymiana jonowa
test wielokrotny
żywica MIEX
absorbancja specyficzna w UV
potencjał tworzenia THM
water treatment
organic compounds
ion exchange
multiple loading jar test
MIEX® resin
SUVA
THMF
Opis:
Przeprowadzono testy laboratoryjne z nową żywicą anionowymienną MIEX®Gold zastosowaną do oczyszczania wody charakteryzującej się małą wartością absorbancji właściwej w nadfiolecie (2,3 m3/gC-m) oraz niewielką zawartością RWO (4,0 gC/m3). Równolegle przeprowadzono te same testy z użyciem znanej żywicy MIEX®DOC. Stwierdzono niewielkie różnice w skuteczności obu żywic, przy czym nowa żywica miała nieznacznie mniejszą (do 6%) zdolność usuwania organicznych składników wody. Niewielka przewaga żywicy MIEX®Gold polegała na większej skuteczności usuwania prekursorów trójhalometanów. Przy dawce chloru 1,0 gCl2/m3 i krotności wymiany objętości żywicy 100 m3/m3, obie żywice umożliwiły zmniejszenie potencjału tworzenia THM o 45% (MIEX®DOC) oraz 55% (MIEX®Gold), podczas gdy przy krotności wymiany 2000 m3/m3 wartości te były mniejsze i wynosiły odpowiednio 14% i 22%. W wypadku obu żywic ilość THM wytworzona w odniesieniu do 1 grama RWO korelowała z jednostkową dawką chloru ([Cl2]/[RWO]), wykazując tendencję rosnącą. W przypadku żywicy MIEX®Gold stwierdzono nieznacznie mniejsze wartości stosunku [THM]/[RWO], przy czym przy małej krotności wymiany (100 m3/m3) różnica ta była wyraźna (MIEX®DOC:MIEX®Gold: [Cl2]/[RWO]=0,88:0,79 gCl2/gC, [THM]/[RWO]=11,75:8,66 gTHM/gC). Względnie zbliżone efekty pracy obu żywic nie wskazują na zasadność stosowania nowego typu żywicy w oczyszczaniu wód o małej wartości absorbancji właściwej. Różnice w zdolności separacyjnej obu typów żywic nie są dobrze rozpoznane, dlatego rozważanie ich stosowania wymaga każdorazowo weryfikacji doświadczalnej.
Laboratory tests with a new anion-exchange resin MIEX®Gold were carried out for treatment of water with low specific UV absorbance (SUVA) (2.3 m3/gC-m) and low DOC content (4.0 gC/m3). Concurrently, the same tests for the known MIEX®DOC resin were performed. Small differences in efficacy of both resins were demonstrated, with the new one showing slightly lower (up to 6%) ability of organic compound removal from water. A minor advantage of MIEX®Gold was higher trihalomethane (THM) precursor removal efficacy. At a chlorine dose of 1.0 gCl2/m3 and bed volume of 100 dm3/dm3 both resins allowed for reduction in THM formation potential (THMFP), namely by 45% for MIEX®DOC and 55% for MIEX®Gold. However, at a bed volume of 2000 dm3/dm3 those values were lower, i.e. 14% and 22%, respectively. For both resins, amount of THM formed in relation to 1 gram of DOC correlated with a unit chlorine dose ([Cl2]/[DOC]) and a tendency was growing. Slightly lower values of [THM]/[DOC] were demonstrated for MIEX®Gold resin. However, at a low bed volume (100 m3/m3) the difference was significant (MIEX®DOC:MIEX®Gold: [Cl2]/[DOC]=0.88:0.79 gCl2/gC, [THM]/[DOC]=11.75:8.66 gTHM/gC). Relatively similar operating efficacies of both resins do not support new resin type application for treatment of water with low specific absorbance. Differences in separation preferences of the both resin types remain not understood very well. Thus their application would require experimental validation on case by case basis.
Źródło:
Ochrona Środowiska; 2016, 38, 2; 23-27
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies