Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Gładysz, M." wg kryterium: Wszystkie pola


Wyświetlanie 1-1 z 1
Tytuł:
Occurrence of Legionella spp. in Polish hotels between 2009-2013 and 2014-2016: a comparative study
Autorzy:
Gładysz, I.
Sikora, A.
Wójtowicz-Bobin, M.
Karczewska, Z.M.
Karczewski, J.
Powiązania:
https://bibliotekanauki.pl/articles/2088167.pdf
Data publikacji:
2019
Wydawca:
Uniwersytet Opolski. Instytut Nauk o Zdrowiu
Tematy:
Legionnaires’ disease
Legionella pneumophila
water
Opis:
Background: Legionella spp. have been found in both natural and manmade water systems, coastal waters, thermal waters, moist soils, clays, and near wastewater discharge sites. Aim of the study: This study aims to report a comparative, retrospective epidemiological analysis of water testing study results indicating the presence of Legionella spp. in Poland between 2009-2013 and 2014-2016. This study is a comparative retrospective epidemiological analysis of individual tests for the presence of Legionella spp. in hotels between two different time periods. The two time periods being compared in this study are between 2009-2013 (n=369 hotels) and 2014-2016 (n=174 hotels). Reporting has been performed in accordance with the STROBE checklist. Material and methods: Hot water samples were collected by employees of the Sanitary and Epidemiological Station in Poland as part of routine water quality monitoring. Samples were taken from the water supply systems of 369 hotels, representing 19.59% of total hotels in Poland, from January 2009 until December 2013. Samples were taken from the water supply systems of 174 hotels, representing 7.51% of total hotels in Poland, from January 2014 until December 2016. Results: The percentage of facilities classified as Group I remained comparable for the period between 2009 and 2013 compared to the period between 2014 and 2016. The percentage of facilities classified as Group II, however, showed a clear upward trend between 2014 and 2016 compared to the time period between 2009 and 2013. The percentage of facilities classified as Group III showed a clear downward trend between 2014 and 2016 compared to the time period between 2009 and 2013. Conclusions: The colonization rates observed in this comparative study indicate that the aquatic environment in these facilities requires constant monitoring to lower the risk of legionellosis. The increased colonization of hotel water networks with Legionella spp. is a serious health problem that requires constant monitoring.
Źródło:
Medical Science Pulse; 2019, 13, 4; 27-31
2544-1558
2544-1620
Pojawia się w:
Medical Science Pulse
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-1 z 1

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies