Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Actinomycetes" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Assessment of microbiological quality of air in the selected sites situated by the main roads of Kraków
Ocena jakości mikrobiologicznej powietrza w wybranych punktach usytuowanych przy głównych szlakach komunikacyjnych Krakowa
Autorzy:
Lenart-Boroń, Anna
Juraszek, Katarzyna
Powiązania:
https://bibliotekanauki.pl/articles/1177748.pdf
Data publikacji:
2014
Wydawca:
Instytut Medycyny Wsi
Tematy:
Kraków
actinomycetes
air quality
bacteria
fungi
staphylococci
Opis:
Introduction. Kraków is one of the most beautiful but also one of the most crowded Polish cities with large numbers of cars, pedestrians and cyclists travelling each day. There has been an increasing concern about the human exposure to bioaerosols, which can occur, among others, at the sites characterized by increased dustiness, such crowded streets. The aim of this study was to evaluate the microbiological quality of air in the selected sites situated by the main roads in Kraków. Material and methods. Air samples were collected in 10 sites located by the main roads, using a MAS-100 impactor four times per year. Four microbial groups were enumerated: mesophilic bacteria, fungi, actinomycetes and staphylococci. The results were expressed as colony forming units per m3 of air and compared with Polish Standards concerning microbiological air quality. Results. The greatest bacterial and fungal aerosol concentration was observed in autumn, when atmospheric conditions could have promoted abundance of those microorganisms. In general, fungi were the most numerous group of airborne microorganisms, while staphylococci were the least numerous. The number of actinomycetes was alarmingly high in all sites. It was found that seasonal differences in the bioaerosol concentration were statistically significant and the recorded differences could have been affected by atmospheric conditions. Conclusions. The conducted studies showed that in terms of airborne bacteria and fungi, the air in the examined locations was microbiologically unpolluted. However, high numbers of airborne actinomycetes were observed in all sites, which can cause adverse health effects in pedestrians or cyclists who are frequently exposed to bioaerosols by the main routes in Kraków. Statistically significant variability was found in the prevalence of the examined microorganisms in different seasons of the year.
Wstęp. Kraków jest jednym z najpiękniejszych i zarazem jednym z najbardziej zatłoczonych polskich miast, w którym każdego dnia po ulicach przemieszczają się tysiące samochodów, a także przechodniów i rowerzystów. Coraz większe zaniepokojenie budzi problem narażenia ludzi na aerozol biologiczny, którego podwyższone stężenie może wystąpić między innymi w zapylonych miejscach, takich jak zatłoczone ulice. Z tego powodu, celem badań była ocena jakości mikrobiologicznej powietrza w wybranych punktach przy głównych szlakach komunikacyjnych Krakowa. Materiał i metody. Próbki powietrza pobierano w 10 punktach umiejscowionych wzdłuż głównych dróg, czterokrotnie w ciągu roku, przy użyciu impaktora MAS- 100. Oznaczono liczebność czterech grup mikroorganizmów – bakterii mezofilnych, grzybów, promieniowców i gronkowców. Wyniki wyrażono jako jednostki tworzące kolonie w m3 powietrza i porównano z Polskimi Normami dotyczącymi jakości mikrobiologicznej powietrza atmosferycznego. Wyniki. Najwyższe stężenie bioaerozolu bakteryjnego i grzybowego stwierdzono jesienią, gdy warunki atmosferyczne były korzystne dla zwiększonej liczebności drobnoustrojów w powietrzu. Ogółem, grzyby były najliczniejszą grupą drobnoustrojów, a najmniej liczną były gronkowce. We wszystkich badanych lokalizacjach liczebność promieniowców była niepokojąco wysoka. Stwierdzono istnienie istotnej statystycznie zmienności sezonowej w stężeniu bioaerozolu, przy czym różnice te mogły być wynikiem zmiennych warunków atmosferycznych. Wnioski. Przeprowadzone badania wykazały, że pod względem stężenia bakterii i grzybów powietrze w badanych lokalizacjach było mikrobiologicznie czyste. Jednakże we wszystkich lokalizacjach stwierdzano wysokie stężenie promieniowców, co może prowadzić do niekorzystnych skutków zdrowotnych np. u pieszych i rowerzystów, którzy często narażeni są na kontakt z bioaerozolem, podróżując wzdłuż głównych dróg w Krakowie. Stwierdzono istotną statystycznie zmienność liczebności badanych drobnoustrojów w różnych porach roku.
Źródło:
Medycyna Środowiskowa - Environmental Medicine; 2014, 17, 2; 15-22
1505-7054
2084-6312
Pojawia się w:
Medycyna Środowiskowa - Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bioaerosol-forming actinomycetes at the selected sites of Kraków
Promieniowce tworzące bioaerozol w wybranych miejscach Krakowa
Autorzy:
Grzyb, J.
Frączek, K.
Powiązania:
https://bibliotekanauki.pl/articles/389452.pdf
Data publikacji:
2013
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
Actinomycetes
bioaerosol
air dustiness
Kraków
promieniowce
bioaerozol
zapylenie
Opis:
Krakow is a city where, due to mostly so-called low-stack emissions and intensified traffic, air dustiness continues to increase and often, especially in winter, the threshold values of dustiness are exceeded. Air dustiness increases the number of airborne microorganisms, as they are associated with particles of dust to form bioaerosols. Actinomycetes are one of the most significant components of bioaerosol. Their presence in bioaerosol is dangerous to human health, since even very low concentrations of these microorganisms can cause allergic reactions. The aim of this study was to verify the relationship between the concentration of actinomycetes in the air of Krakow depending on spatial variation of thermal conditions and the degree of air dustiness. The study was conducted using a cascade impactor for bioaerosol particle separation, including the respirable fraction. Moreover, the measurements of air dustiness were performed simultaneously, separating 4 dust fractions. The research was conducted over 12 months (full calendar year) and the measurements were performed once per month, within one day, at 16 research sites. The lowest average numbers of actinomycetes were recorded in places characterized by little urban green space (eg Main Square or crossroads). On the other hand, the highest numbers were found in green areas (eg Blonia Park meadows, green area at the Krakow University of Technology). Based on the normative classification of air quality (Polish Standard PN-89/Z-04111/02) the number of actinomycetes in 75 % measurements showed that the air was polluted, including heavily polluted air in 16 % measurements. The most common actinomycetes belonged to the genus Streptomyces (St. albus, St. badius, St. globisporus).
Kraków jest miastem, w którym głównie na skutek tzw. niskiej emisji oraz wzmożonego ruchu kołowego zapylenie powietrza wciąż wzrasta i nierzadko szczególnie w okresie zimowym są przekraczane progowe wartości zapylenia. Zapylenie powietrza wpływa na zwiększenie się ilości drobnoustrojów Bioaerosol-Forming Actinomycetes at the Selected Sites of Krakow 451 w powietrzu, gdyż te ostatnie wiążą się z cząstkami pyłów, tworząc bioaerozol. Jednym z ważnych składników bioaerozolu są promieniowce. Ich obecność w bioaerozolu jest groźna dla zdrowia ludzkiego, gdyż nawet ich bardzo niskie stężenia mogą działaæ alergizująco. Celem niniejszych badań była weryfikacja zależności pomiędzy stężeniem promieniowców w powietrzu na obszarze Krakowa, przestrzennym zróżnicowaniem stosunków termicznych oraz stopniem zapylenia powietrza. Do badañ użyto impaktora kaskadowego w celu uzyskania rozdziału cząstek bioaerozolu, w tym frakcji respirabilnej. Jednocześnie wykonywane były pomiary stopnia zapylenia z podziałem na 4 frakcje. Badania były wykonywane przez 12 miesięcy (pełen rok kalendarzowy), raz w miesiącu, w ciągu jednego dnia, na 16 stanowiskach pomiarowych. Najniższe średnie liczebności promieniowców notowano w miejscach, gdzie jest mało zieleni (np. Rynek Główny, czy też skrzyżowanie ulic). Najwyższe liczebności stwierdzono na terenach zielonych (np. Błonia, teren zielony przy Politechnice Krakowskiej). Promieniowce zgodnie z klasyfikacją jakości powietrza atmosferycznego (Polska Norma PN-89/Z-04111/ 02) powodowały, że w przypadku 75 % wykonanych pomiarów powietrze było zanieczyszczone, w tym silnie zanieczyszczone dla 16 % pomiarów. Najczęściej stwierdzano występowanie promieniowców z rodzaju Streptomyces (St. albus, St. badius, St. globisporus).
Źródło:
Ecological Chemistry and Engineering. A; 2013, 20, 4-5; 443-452
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microbial Air Contamination on the Marketplaces in Krakow
Mikrobiologiczne zanieczyszczenie powietrza na placach targowych w Krakowie
Autorzy:
Grzyb, J.
Michałek, J.
Frączek, K.
Ropek, D.
Powiązania:
https://bibliotekanauki.pl/articles/387982.pdf
Data publikacji:
2012
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
mikroflora powietrza
plac targowy
Kraków
bakterie
grzyby
promieniowce
air microflora
marketplace
bacteria
fungi
Actinomycetes
Opis:
Microbiological air research was conducted on five different marketplaces in Krakow and on the Blonia meadows in different seasons. The air was sampled by using the collision method with a microbiological air-sampler MAS-100 (Merck). Abundance of bacteria ranged from 42 to 2300 CFU/m3. Fungi were seldom present and ranged from 30 to 3460 CFU/m3. Actinomycetes were most uncommon and their quantities ranged from 0 to 140 CFU/m3, but quantities that ranged over 100 CFU/m3 also caused heavy atmospheric air pollution. Research proved a tight correlation between microorganisms’ occurrence and seasons. During summer bacteria appeared in larger numbers whereas fungi and actinomycetes had larger quantities during springtime.
Badania mikrobiologiczne powietrza przeprowadzone zostały na pięciu placach targowych Krakowa i na miejskim terenie zieleni (Błoniach) - jako kontroli w różnych porach roku. Próbki powietrza pobierane były metodą zderzeniową za pomocą aspiratora MAS-100 firmy Merck. Liczebność bakterii w powietrzu badanych placów targowych wahała się od 42 do 2300 jtk/m3, natomiast grzybów pleśniowych od 30 do 3460 jtk/m3. Promieniowce występowały najrzadziej w ilościach od 0 do 140 jtk/m3, lecz stwierdzone liczebności wynoszące ponad 100 jtk/m3 również wskazywały na silne zanieczyszczenie powietrza atmosferycznego. Badania wykazały korelację występowania mikroorganizmów z porą roku. W okresie letnim maksimum swojego występowania miały bakterie, natomiast grzyby i promieniowce w okresie wiosennym.
Źródło:
Ecological Chemistry and Engineering. A; 2012, 19, 3; 267-273
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies