Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "GC-MS analysis" wg kryterium: Temat


Wyświetlanie 1-5 z 5
Tytuł:
Spectroscopic analysis of phytochemical compounds in Garcina kola leaf extract
Autorzy:
Anadebe, V. C.
Okafor, N. A.
Okafor, B. O.
Emmanuel, C. C.
Powiązania:
https://bibliotekanauki.pl/articles/1113583.pdf
Data publikacji:
2017
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
FTIR Analysis
GC-MS
Garcina kola leaf
Phytochemical Analysis
Opis:
Garcina kola leaves were collected, washed, dried and powdered. The ethanol extracts were first prepared by the simple method of cold extraction. The extracts were then characterized by the Phytochemical analysis, Fourier transform infrared spectroscopy (FTIR) and Gas chromatography mass spectroscopy (GC-MS) to identify the fatty acids and heterocyclic compounds present in the leaf extracts. The FTIR analysis shows a variation of the peaks that indicate there is synergy among the functional groups of the extract. Moreover, the phytochemical analysis revealed the presence of alkaloids, flavonoids, phenol, saponins, tannins and steroids. The study reveals that the chemical constituents of Garcina kola leaf may be behind their medicinal values in phytomedicine.
Źródło:
World News of Natural Sciences; 2017, 15; 162-168
2543-5426
Pojawia się w:
World News of Natural Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mobilne przyrządy GC-MS
Mobile GC-MS devices
Autorzy:
Budzyńska, E.
Grabka, M.
Witkiewicz, Z.
Puton, J.
Jasek, K.
Powiązania:
https://bibliotekanauki.pl/articles/271211.pdf
Data publikacji:
2017
Wydawca:
Centralny Ośrodek Badawczo-Rozwojowy Aparatury Badawczej i Dydaktycznej, COBRABiD
Tematy:
GC-MS
przyrządy mobilne
analiza środowiskowa
mobile
environmental analysis
Opis:
Jednym z kierunków rozwoju analizy chemicznej–szczególnie w przypadku zanieczyszczeń środowiska – jest dążenie do wykonywania analiz w miejscach, w których istnieje potrzeba wykrycia substancji chemicznych, ich identyfikacji i oznaczenia ilościowego. Skutkuje to coraz większym zainteresowaniem przyrządami przenośnymi lub przewoźnymi, w których skład wchodzi chromatograf gazowy. Przyrządy mobilne, przeznaczone do stosowania poza laboratorium, charakteryzują się mniejszymi wymiarami i masami niż chromatografy laboratoryjne. Są to przyrządy przystosowane do przewożenia w samochodach lub takie, które może przenosić jedna osoba. W niniejszym przeglądzie opisujemy mobilne przyrządy stanowiące połączenie chromatografu gazowego ze spektrometrem mas. Aby umożliwić wykonywanie analiz za pomocą przyrządów GC-MS w terenie, konieczne jest przystosowanie kolumny chromatograficznej do małych wymiarów przyrządu i do pracy w reżimie szybkiej chromatografii gazowej, zminiaturyzowanie detektorów mas, a także dopasowanie sposobu zaopatrzenia w energię elektryczną oraz gazy nośne do warunków polowych. W pracy tej podano przy- kłady komercyjnie dostępnych mobilnych przyrządów GC-MS wraz z ich zastosowaniami.
One of the directions of development of chemical analysis is the pursuit of analysis, especially in the case of environmental pollution, where is a need to detect, identify and quantify chemicals. This results in a growing interest in portable or mobile devices, which include a gas chromatographs. Out-of-laboratory mobile instruments are characterized by smaller dimensions and masses than laboratory chromatographs. These are instruments carried in cars or which can be carried by one person. In this review we describe mobile devices that combine gas chromatograph with mass spectrome- ter. The process of transferring GC-MS analytical capabilities into the field consists of adjusting the chromatographic column to small dimensions of the instrument and working as fast chromatography, miniaturization of mass detectors as well as adjusting the way of supplying electricity and carrier gases to field conditions. This work also presents some examples of commercially available GC-MS mobile devices and their applications.
Źródło:
Aparatura Badawcza i Dydaktyczna; 2017, 22, 2; 117-124
2392-1765
Pojawia się w:
Aparatura Badawcza i Dydaktyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the compounds from the BTEX group, emitted during thermal decomposition of alkyd resin
Autorzy:
Kubecki, M.
Holtzer, M.
Bobrowski, A.
Dańko, R.
Grabowska, B.
Żymankowska-Kumon, S.
Powiązania:
https://bibliotekanauki.pl/articles/380216.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
masa formierska
wiązanie
BTEX
analiza termiczna
GC-MS
moulding sand
binding
thermal analysis
Opis:
Suitability of the given binding agent for the moulding sands preparation depends on the one hand on the estimation of technological properties of the sand and the mould made of it and the obtained casting quality and on the other hand on the assessment of this sand influence on the natural and working environment. Out of moulding sands used in the foundry industry, sands with organic binders deserve a special attention. These binders are based on synthetic resins, which ensure obtaining the proper technological properties and sound castings, however, they negatively influence the environment. If in the initial state these resins are not very dangerous for people and for the environment, thus under an influence of high temperatures they generate very harmful products, being the result of their thermal decomposition. Depending on the kind of the applied resin (phenol-formaldehyde, urea, furfuryl, urea-furfuryl, alkyd) under an influence of a temperature such compounds as: furfuryl alcohol, formaldehyde, phenol, BTEX group (benzene, toluene, ethylbenzene, xylene), and also polycyclic aromatic hydrocarbons (PAH) can be formed and released. The aim of the study was the development of the method, selection of analytical methods and the determination of optimal conditions of formation compounds from the BTEX group. An emission of these components constitutes one of the basic criteria of the harmfulness assessment of binders applied for moulding and core sands. Investigations were carried out in the specially designed set up for the thermal decomposition of organic substances in a temperature range: 5000C - 13000C at the laboratory scale. The object for testing was alkyd resin applied as a binding material for moulding sands. Within investigations the minimal amount of adsorbent necessary for the adsorption of compounds released during the decomposition of the resin sample of a mass app. 15 mg was selected. Also the minimal amount of solvent needed for the desorption of compounds adsorbed in the column with adsorbent was found. The temperature range, in which the maximal amounts of benzene, toluene, ethylobenzene and xylenes are released from the resin, was defined. The qualitative and quantitative analyses of compounds from the BTEX group were performed by means of the gas chromatography combined with the mass spectrometry (GC/MS).
Źródło:
Archives of Foundry Engineering; 2012, 12, 3; 69-74
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development and Validation of a GC-MS Method for the Simultaneous Quantitation of Zearalenone and Its Metabolites in Water
Opracowanie i walidacja metody GC-MS do równoczesnego oznaczania zearalenonu i jego metabolitów w wodzie
Autorzy:
Dudziak, M.
Powiązania:
https://bibliotekanauki.pl/articles/388081.pdf
Data publikacji:
2010
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
zearalenon
metabolity
mykoestrogeny
SPE
GC-MS
oznaczanie
analiza wody
zearalenone
metabolites
mycoestrogens
determination
water analysis
Opis:
The method of simultaneous determination of zearalenone and its metabolites in water with use of GC-MS chromatography was evaluated. The solid phase extraction SPE was used for analytes separation from water and as an enrichment method. The influence of compounds concentration and water sample volume on analytes recovery was investigated. The chromatographic analysis was preceded by conversion of compounds to trimethylsilyl ethers derivatives. The developed SPE-derivatization-GC/MS method allow to separate quaternary mixture of mycoestrogens with the quantitative analysis in water, when their concentration is greater than 0.2–0.5 ng/dm3. The repeatability of the results was from 1 to 8 %. The recovery of compounds exceeded 60 % for samples contains from 50 to 200 ng/dm3 of mycotoxins. The concentration of analytes and volume of the sample (100–500 cm3) did not have an influence on the extraction output. The developed method can be applied to analyze water samples containing mycoestrogens at the level of ng/dm3.
Ocenie poddano metodę równoczesnego oznaczania zearalenonu i jego metabolitów w wodzie z użyciem chromatografii GC-MS. Ekstrakcja do fazy stałej SPE wykorzystana została jako metoda wydzielania i wzbogacania analitów z wody. Badano wpływ stężenia i objętości próbki wody na odzysk związków. Z kolei przed chromatograficznym oznaczeniem mykoestrogeny przeprowadzono w etery trimetylosiliowe. Metoda SPE-derywatyzacja-GC/MS umożliwia rozdział czteroskładnikowej mieszaniny mykoestrogenów i ich ilościowe oznaczenie w wodzie na poziomie stężeń 0,2–0,5 ng/dm3. Powtarzalność oznaczeń była w zakresie 1–8 %. Wyznaczony odzysk związków dla stężenia w zakresie 50–200 ng/dm3 przekraczał 60 %. Nie obserwowano znacznego wpływu stężenia analitów jak i objętości próbki wody (100–500 cm3) na wydajność ekstrakcji. Przedstawioną metodykę można więc zastosować do kontroli analitycznej obecności mykoestrogenów w środowisku wodnym na poziome stężeń ng/dm3.
Źródło:
Ecological Chemistry and Engineering. A; 2010, 17, 11; 1397-1404
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie metody GC-MS do oznaczania zawartości kwasów tłuszczowych w ściekach zanieczyszczonych olejami jadalnymi
The application of gc-ms method for determination of fatty acids concentrations in wastewater containing eatable oils
Autorzy:
Łobos-Moysa, E.
Dudziak, M.
Powiązania:
https://bibliotekanauki.pl/articles/296859.pdf
Data publikacji:
2011
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
kwasy tłuszczowe
GC-MS
ekstrakcja ciecz-ciecz
analiza ścieków zaolejonych
oleje jadalne
fatty acids
liquid-liquid extraction
oil wastewater analysis
edible oil
Opis:
Ocenie poddano metodę oznaczania kwasów tłuszczowych w ściekach zaolejonych. Kwasy tłuszczowe wydzielano, stosując ekstrakcję ciecz-ciecz dichlorometanem, którą poprzedzono estryfikacją analitów w wodzie roztworem BF3 w metanolu. Do analizy jakościowo-ilościowej ekstraktu użyto GC-MS. Opracowana metoda umożliwia rozdział i identyfikację 12 kwasów tłuszczowych, w tym nasyconych: oktanowy (C8:0), dekanowy (C10:0), mirystynowy (C14:0), palmitynowy (C16:0), stearynowy (C18:0), arachidowy (C20:0), behenowy (C22:0) i lignocerynowy (C24:0), oraz nienasyconych: palmitoleinowy (C16:1), oleinowy (C18:1), linolowy (C18:2) i erukowy (C22:1). Granica oznaczenia metody była w zakresie od 6,3 do 35 µg/dm3 w zależności od badanego związku. Opisana metoda została z powodzeniem zastosowana do oznaczeń kwasów tłuszczowych w ściekach modelowych i komunalnych.
A method for determination of fatty acids in oil wastewater, extracted with dichloromethane, was developed. In research lipid standards of following saturated acids were used: octanoic (C8:0), decanoic (C10:0), lauric myristic (C14:0), palmitic (C16:0), stearic (C18:0), arachidic (C20:0), behenic (C22:0), lignoceric (C24:0) and unsaturated acids: palmitoleic (C16:1), oleic (C18:1), linoleic (C18:2), erucic (C22:1). Fatty acids were esterified using BF3 methanolic solution and gas chromatography-mass spectrometry analysis was peformed. Limite of aqua nitrification was in range from 6.3 to 35 µg/dm3. The measurements characterized with the high degree of analytes recovery, which exceeded 69%. The precision of measurements below 15% was satisfied. The method was successfully applied to the wastewater containing eatable oils. 4 fatty acids (palmitic, stearic, oleic and linoleic) were analysed in the treated municipal watewaters collected in the mechanical-biological watewater treatment plant in Silesia (Poland). Their concentration varied from 0 to 1702 µg/dm3. The same acids were analysed in the symulated wastewaters with rape oil but in low concentrations form 0 to 250 µg/dm3.
Źródło:
Inżynieria i Ochrona Środowiska; 2011, 14, 3; 275-280
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies