Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "fault tolerant control (FTC)" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Fault tolerant control of a PMSM drive in the selected emergency conditions
Autorzy:
Siembab, K.
Powiązania:
https://bibliotekanauki.pl/articles/376452.pdf
Data publikacji:
2013
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
PMSM
PMSM drive
fault-tolerant inverter
FTC
Fault Tolerant Control
Opis:
The paper describes an investigation of fault tolerant control strategies for permanent magnet synchronous motor (PMSM) driven by a fault-tolerant inverter. The inverter is a topology-modified inverter with fault-tolerant capability, which can be configured as the standard 3-phase 6-switch inverter and reconfigured as 3-phase 4-switch or 2-phase 4-switch inverter under the fault condition. By analyzing operating principle of a fault-tolerant inverter and the mathematical model of PMSM, fault tolerant control algorithms are investigated. There is a conclusion that three phase stator windings of PMSM can be effectively operated by controlling only two phase currents. Simulation results show the validity of the proposed methods.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2013, 75; 165-172
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Health management using fault detection and fault tolerant control of multicellular converter applied in more electric aircraft system
Autorzy:
Mahboub, Mohamed Abdelbasset
Rouabah, Boubakeur
Kafi, Mohamed Redouane
Toubakh, Houari
Powiązania:
https://bibliotekanauki.pl/articles/2096199.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
fault tolerant control
FTC
multicellular converters
more electric aircraft
sterowanie tolerujące uszkodzenia
konwertery wielokomórkowe
samolot bardziej elektryczny
Opis:
The increased cost of fuel and maintenance in aircraft system lead to the concept of more electric aircraft, moreover this concept increase the use of power electronic converters in aircraft power system. Since in this application, the reliability is a crucial feature. Therefore, the use of more efficient, reliable and robust power converter with health management capability will be a big challenge. Multicellular topology of power converters has the required performance in terms of efficiency and robustness. However, the increased complexity of control and more power components (power switches and capacitors) goes along with an increase in possibility of failure in multicellular topology. Therefore, the main contribution of this paper is the use of multicellular topology advantageous with fault diagnosis and fault tolerant control in order to increase the robustness reliability. The health management using a fault detection with Fuzzy Pattern Matching (FPM) algorithm when a failure in power switches or flying capacitors of multicellular converter and a Fault Tolerant Control (FTC) with sliding mode of second parallel three cells multicellular converters. Simulation results with Matlab show the increased efficiency and the continuity of work during failure mode in aircraft power system.
Źródło:
Diagnostyka; 2022, 23, 2; art. no. 2022212
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Universal System for Detection and Compensation of Current Sensor Faults in Three-Phase Power Electronic Systems
Autorzy:
Dybkowski, Mateusz
Jankowska, Kamila Anna
Powiązania:
https://bibliotekanauki.pl/articles/2175934.pdf
Data publikacji:
2022
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
FTC
fault-tolerant control system
active rectifier
current sensor
PMSM
permanent magnet synchronous motor
IM
induction motor
diagnostics
Opis:
The article discusses the universal current sensor fault detection and compensation mechanism, which can be applied in three-phase power electronics (PE) symmetrical system. The mechanism is based on the assumption that a symmetrical system can be described using different components in the stationary reference frame. The solution given in article as a Cri-base detector was tested in electrical drives with induction motors (IMs) and permanent magnet synchronous motors (PMSMs). This study also proves that the same algorithm can work stable in active rectifier systems. Such an application of this detector has not been previously reported in the literature. The article describes the detection of various types of faults in different phases. The fault-tolerant voltage-oriented control (FTVOC) of an active rectifier is compared with previously described solutions for IMs and PMSMs. By analysing in various types of systems, the work proves the universality of the detector based on Cri markers.
Źródło:
Power Electronics and Drives; 2022, 7, 42; 267--278
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design station for fault tolerant control systems
Stanowisko projektowania systemów sterowania tolerujących uszkodzenia
Autorzy:
Wasiewicz, P.
Leszczyński, M.
Powiązania:
https://bibliotekanauki.pl/articles/258270.pdf
Data publikacji:
2006
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
sterowanie tolerujące uszkodzenia
FTC
zabezpieczenia systemu
rekonfiguracja systemu
detekcja i lokalizacja uszkodzeń
FDI
fault tolerant control
system protection
system reconfiguration
fault detection and isolation
Opis:
The presented station prepared for the design of fault tolerant control (FTC) systems has been created in the Institute of Automatic Control and Robotics at Warsaw University of Technology. It consists of the hydraulic installation equipped with Emerson's instrumentation, DeltaV-control system and AMandD-advanced monitoring and diagnostic system. The fault tolerance of certain sensors, controllers, actuators, and process components can be achieved by the use of functional redundancy, which consists in the performance of appropriate changes in the operation manner of the faulty system. The various industrial FTC applications and new diagnostic-protection algorithms can be developed on the basis of considered station.
Zaprezentowano stanowisko do projektowania systemów sterowania tolerujących uszkodzenia (FTC) opracowane i zrealizowane w Instytucie Automatyki i Robotyki Politechniki Warszawskiej. Składa się ono z instalacji hydraulicznej wyposażonej w oprzyrządowanie firmy Emerson, system sterowania Delta V oraz zaawansowany system monitorowania i diagnostyki procesów AMandD. Tolerowanie uszkodzeń urządzeń pomiarowych i wykonawczych oraz elementów instalacji technologicznej jest osiągane poprzez zastosowanie redundancji funkcjonalnej polegającej na dokonywaniu odpowiednich zmian w sposobie działania uszkodzonego systemu. Stanowisko umożliwia przygotowywanie przemysłowych aplikacji systemów FTC oraz opracowywanie nowych algorytmów diagnostyczno-zabezpieczających.
Źródło:
Problemy Eksploatacji; 2006, 2; 99-111
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies