Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Roman, D." wg kryterium: Autor


Wyświetlanie 1-5 z 5
Tytuł:
Assessment of muscle load and fatigue with the usage of frequency and time-frequency analysis of the EMG signal
Autorzy:
Bartuzi, P.
Roman-Liu, D.
Powiązania:
https://bibliotekanauki.pl/articles/307422.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
biomechanics
EMG
fatique
muscle load
wavelet
mięśnie
obciążenie
zmęczenie
falka
Opis:
The aim of the study was to determine the effect of the muscle load and fatigue on the values of the parameters calculated on the basis of the time, frequency (Fourier transform) and time-frequency (wavelet transform) analysis of the EMG signal, for low levels of load. Fifteen young men took part in the study. The EMG signal was registered from right side biceps brachii (BB) and trapezius (TR) muscles in static conditions, at load 10%, 20% and 30% MVC (maximal voluntary contraction). On the basis of the analysis there were selected parameters sensitive to force (RMS) and parameters sensitive to fatigue but simultaneously insensitive to force (MPF – mean power frequency determined on the basis of Fourier transform, CMPFdb5 – mean power frequency determined on the basis of the wavelet transform). The results indicate that CMPFdb5 can show similar (muscle BB) or greater (muscle TR) sensitivity to fatigue than MPF. It can suggest that, for low levels of load, the wavelet transform parameters can be more effective in assessing muscle fatigue than the parameters based on the Fourier transform. The obtained results can allow for a more precise analysis of muscle fatigue at low levels of load. Further analysis for a greater number of muscles activated at low levels of load, with the usage of the parameters tested is desirable.
Źródło:
Acta of Bioengineering and Biomechanics; 2014, 16, 2; 31-39
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ typu mięśnia na parametry widma mocy sygnału EMG
The influence of muscle type on EMG power spectrum parameters
Autorzy:
Bartuzi, P.
Roman-Liu, D.
Powiązania:
https://bibliotekanauki.pl/articles/98897.pdf
Data publikacji:
2008
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
sygnał elektromiograficzny
EMG
mięśnie
budowa morfologiczna
electromyographic signal
muscle
morphological structure
Opis:
Celem pracy było opracowanie wskaźników, opartych na widmie mocy sygnału elektromiograficznego (EMG), obrazujących budowę morfologiczną mięśnia. Sygnał EMG został zarejestrowany z mięśni: czworoboczny część zstępująca (trapezius pars descendens-TPD), naramienny część obojczykowa (deltoideus pars clavicularis-DPC), naramienny część barkowa (deltoideus pars acromialis-DPA) oraz zginacz łokciowy nadgarstka (flexor carpi ulnaris-FCU), podczas badań w 6 wariantach obciążenia. W wyniku analizy opracowano parametry widma mocy sygnału EMG, szczególnie wrażliwe na zmiany w strukturze mięśnia.
The aim of this study was to develop coefficients of electromyographic (EMG) signal, which show the morphological properties of muscle. Measurements of EMG signal from muscles: trapezius pars descendens (TPD), deltoideus pars clavicularis (DPC), deltoideus pars acromialis (DPA) and flexor carpi ulnaris (FCU), during research in 6 variants of load were realized. As the result of analysis the parameters based on power spectrum of EMG signal were worked out. Differences between morphological structure of muscle can be described using these parameters.
Źródło:
Aktualne Problemy Biomechaniki; 2008, 2; 7-12
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental Verification of the Computerized Method for Work Space Optimization in Conditions of Static Work
Autorzy:
Roman-Liu, D.
Kędzior, K.
Powiązania:
https://bibliotekanauki.pl/articles/91230.pdf
Data publikacji:
1999
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
EMG
upper extremity load
intermittent load
constant load
kończyny górne
obciążenie kończyn
obciążenie stałe
miejsce pracy
Opis:
The aim of this study was to verify a theoretical model for upper extremity work space optimization. In order to do that, experimental studies were conducted in which two parameters of the electromyography (EMG) signal were analyzed: AMP (amplitude calculated as Root Mean Square) and SZC (coefficient of the slope of the regression line between time and Zero Crossing values). Values of forces in muscles (parameter MOD) were calculated from theoretical studies. A comparison of experimental (AMP, SZC) and theoretical (MOD) parameters was performed by analyzing the coefficient of correlation between those parameters and differentiation of muscular load according to external load value. Analysis showed that the theoretical and experimental results are in step, which means that the developed model can be used for upper extremity work space optimization.
Źródło:
International Journal of Occupational Safety and Ergonomics; 1999, 5, 1; 109-124
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of upper extremity position on EMG signal measures calculated in time, frequency and time-frequency domains
Autorzy:
Wang, J.
Bartuzi, P.
Roman-Liu, D.
Powiązania:
https://bibliotekanauki.pl/articles/306619.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
upper extremity
EMG
position
time-frequency domain
postawa ciała
biomechanika
Opis:
The aim of this study was to investigate the relationship between time-frequency, time and frequency measures when considering various upper extremity positions below the level of the shoulder and in trapezius as well as deltoideus muscles. During the experiment, 15 subjects performed a task that involved screwing and unscrewing a screw cap on a board in six different locations, i.e., there were six upper extremity positions. Variables were calculated in the time, frequency and time-frequency domains on a recorded EMG signal. The results showed that parameters analyzed in the time-frequency domain were more sensitive to changes in position than parameters analyzed in the frequency domain.
Źródło:
Acta of Bioengineering and Biomechanics; 2013, 15, 4; 83-91
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Influence of Fatigue on Muscle Temperature
Autorzy:
Bartuzi, P.
Roman-Liu, D.
Wiśniewski, T.
Powiązania:
https://bibliotekanauki.pl/articles/90607.pdf
Data publikacji:
2012
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
EMG
muscle fatigue
muscle temperature
biceps brachii
Opis:
The aim of the study was to investigate the possibility of using infrared (IR) thermography for assessing muscle fatigue during low effort. Three tests at constant levels of load 5, 15 and 30% of maximum voluntary contraction (MVC) lasting 5 min each were performed on a group of 10 men. Temperature and electromyographic (EMG) signal were registered from biceps brachii (BB). Analysis focused on the influence of load on the values and changes in time of muscle temperature. Correlations between temperature and EMG parameters (RMS, MPF and MF) were also analysed. Constant load sustained during the tests resulted in an increase in the temperature of BB. There were statistically significant correlations between temperature and EMG parameters for most subjects. Results of the study suggest that IR thermography can be an alternative or supplementary method for assessing muscle fatigue at low levels of contraction.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2012, 18, 2; 233-243
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies