Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "EEG" wg kryterium: Temat


Tytuł:
Predyktory odpowiedzi na leczenie przeciwdepresyjne w zapisie EEG i QEEG
EEG and QEEG biomarkers as predictors of antidepressant treatment response
Autorzy:
Radziszewska, Monika
Kaźmierski, Jakub
Sobów, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/944109.pdf
Data publikacji:
2015
Wydawca:
Medical Communications
Tematy:
EEG
alpha asymmetry
depression
predictors of treatment outcome
quantitative EEG
eeg
asymetria alfa
depresja
ilościowe eeg
predyktory odpowiedzi na leczenie
Opis:
The aim of this paper is to present current research on the role of EEG and QEEG (quantitative electroencephalogram) prognostic indicators in the prediction of antidepressant treatment outcomes. Depression is currently one of the most common psychiatric disorders with a lifetime prevalence of 7–25%. The choice of antidepressant is still based on a trial-and-error procedure, which is often unsuccessful. Therefore, further research is necessary to establish objective biomarkers and their combination in order to proceed to a faster and more efficacious treatment of depression. In quantitative EEG (QEEG) research, various pretreatment differences in QEEG measures have been reported to be associated with improved antidepressant treatment outcomes. In particular, the following correlations seem to be clinically significant: lower pretreatment theta power, decreased theta cordance 48 h to 2 weeks after start of medication, greater alpha power, increased theta in the rostral anterior cingulate, higher alpha power over the right hemisphere. In contrast increased theta and delta power have been associated with poor treatment response.
Celem artykułu jest przedstawienie aktualnych badań dotyczących roli wskaźników prognostycznych EEG i QEEG (ilościowa elektroencefalografia) w przewidywaniu rezultatów leczenia przeciwdepresyjnego. Depresja należy do najczęstszych zaburzeń psychicznych; rozpowszechnienie w populacji to 7–25% w ciągu całego życia. Wybór leku przeciwdepresyjnego opiera się na metodzie prób i błędów, co często wiąże się z niepowodzeniami. Konieczne są dalsze badania zmierzające do ustalenia obiektywnych biomarkerów oraz ich kombinacji w celu przyspieszenia leczenia depresji i zwiększenia jego skuteczności. W badaniach z zastosowaniem QEEG różnice w pomiarach przed leczeniem korelowały z późniejszą poprawą kliniczną. W szczególności istotne klinicznie wydają się następujące zależności: niższa moc theta przed włączeniem leczenia, spadek wskaźnika kordancji theta w czasie od 48 godzin do 2 tygodni po rozpoczęciu farmakoterapii, wzrost mocy alfa, wzrost mocy theta nad zakrętem obręczy, większa moc alfa nad prawą półkulą. Z kolei wzrost mocy theta i delta wiąże się ze słabą odpowiedzią na leczenie przeciwdepresyjne.
Źródło:
Psychiatria i Psychologia Kliniczna; 2015, 15, 1; 19-25
1644-6313
2451-0645
Pojawia się w:
Psychiatria i Psychologia Kliniczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie elektroencefalograficzne wybranych reakcji ośrodków mózgowych spowodowanych efektem otwarcia oczu
Electroencephalographic research of selected reaction centers of the brain caused by an eye-opening effect
Autorzy:
Kościuszko, P.
Ciesielka, W.
Gołaś, A.
Powiązania:
https://bibliotekanauki.pl/articles/262148.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
EEG
elektroencefalografia
mózg
otwarcie oczu
EEG electroencephalography
brain
eye-opening
Opis:
W pracy opisano badania i analizę sygnałów elektroencefalograficznych zarejestrowanych w trakcie czynności otwierania oczu. Eksperyment rejestracji w określonych przedziałach czasowych zmian sygnału EEG, spowodowanych otwieraniem oczu przez badanego. W eksperymencie wykorzystano metodę 10-20 rozmieszczenia elektrod oraz wykorzystano 19 elektrod do rejestracji aktywności bioelektrycznej mózgu na czterech częściach kresomózgowia (czołowej, ciemieniowej, potylicznej oraz skroniowych). Zaproponowano algorytm procesu określenia wektora symptomów. Do określenia elementów niniejszego wektora wykorzystano wartości: maksymalne, minimalne oraz ich przyrost, przeprowadzono analizę za pomocą krótkoczasowej transformaty, analizę za pomocą ciągłej i dyskretnej transformacji falkowej. Badania wykazały możliwość wyodrębnienia pewnych sygnałów, w których wartości poszczególnych parametrów są do siebie zbliżone i znacząco się różnią od innych parametrów sygnałów. Uzyskane wyniki badań mają charakter poznawczy i stanowią podstawę do przeprowadzania kolejnych eksperymentów.
The paper presents an analysis of electrophysiological signals recorded in the course of eye-opening. The EEG signals are registered at certain intervals and changes caused by opening eyes are monitored. In the experiment the method 10-20 for electrodes placement (19 electrodes) was exploited for recording bioelectric activity of the brain in four parts of the forebrain (frontal, parietal, occipital and temporal lobes). An algorithm for determining the symptom’s vector was proposed. To determine the elements of this vector the following values were used: maximum, minimum, and increase. For the analysis, short-time Fourier transform and continuous and discrete wavelet transform were used. Studies have shown the ability to isolate certain signals, in which the values of individual parameters are similar and differ significantly from the other signal parameters. The results described in the article are purely cognitive and provide the basis for conducting further experiments.
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2014, 20, 3; 144-155
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An egg mobile device as a game controller
Autorzy:
Dawid, Aleksander
Buchwald, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/1987060.pdf
Data publikacji:
2021-12-30
Wydawca:
Politechnika Gdańska
Tematy:
EEG
EEG signal disturbance
signal processing
amplitude driven control
game controller
Opis:
In this work the real-time control of computer games was explored by a single electrode mobile electroencephalography (EEG) device with a Bluetooth interface. The amplitude variation in the two frequency bands of 4-12 Hz and 60-200 Hz was selected as the real-time control parameter. The frequency-domain of a raw EEG signal was calculated using the discrete Fourier transform. The time-dependent signal samples equal to 512, 1024, and 2048 time points in size were used in our research. The well-known classic Pong game was used to try out our controller. The developed software handles communication with the device and real-time game rendering. The .NET Framework with the C# programming language was used as a develop-ment tool. 50 game play trials were made for each controller setup. The obtained results are promising for the possible use of the device in real-time communication with computer devices for people with hand disabilities.
Źródło:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk; 2021, 25, 4; 397-407
1428-6394
Pojawia się w:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stimuli design for SSVEP-based brain computer-interface
Autorzy:
Jukiewicz, M.
Cysewska-Sobusiak, A.
Powiązania:
https://bibliotekanauki.pl/articles/226402.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
EEG
OpenBCI
SSVEP
BCI
Opis:
The paper presents a process of stimuli design for SSVEP-based brain computer-interface. A brain computerinterface can be used in direct communication between a brain and a computer, without using muscles. This device is useful for paralyzed people to communicate with the surrounding environment. Design process should provide high accuracy recognition of presented stimuli and high user comfort. It is widely known how to make stimuli for BCI which are using high-grade EEG. Over recent years cheaper EEGs are becoming more and more popular, for example OpenBCI, which uses ADS1299 amplifier. In this article we review past works of other authors and compare it with our results, obtained using EEG mentioned before. We try to confirm that it is possible to use successfully OpenBCI in BCI projects.
Źródło:
International Journal of Electronics and Telecommunications; 2016, 62, 2; 109-113
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmiany aktywności fal mózgowych pod wpływem treningu neurofeedback u zawodników judo
Changes in the activity of brain waves under the influence neurofeedback training of judo players
Autorzy:
Krawczyk, Magdalena
Kowalczyk, Magdalena
Żak, Marcin
Daros, Karolina
Gozdowski, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/459683.pdf
Data publikacji:
2019
Wydawca:
Fundacja Pro Scientia Publica
Tematy:
Neurofeedback
judo
biofeedback
EEG
Opis:
Cel badań. Celem niniejszego badania była analiza dynamiki zmienności wartości fal Theta i Beta w grupach eksperymentalnej i kontrolnej po kolejnych sesjach biofeedback oraz określenie optymalnej liczby jednostek treningowych wystarczających do osiągnięcia celu badania, jakim była poprawa szybkości reakcji w badanej grupie zawodników judo. Metoda. W badaniu wzięło udział 12 mężczyzn – zawodników kadry narodowej Polskiego Związku Judo. Zawodnicy uczestniczyli w dwóch cyklach treningowych, każdy po 15 sesji. Czas trwania treningu wynosił 4 minuty. W pierwszej sesji treningi odbywały się co drugi dzień. Druga seria badań, która odbyła się po czterotygodniowej przerwie, charakteryzowała się tym samym czasem trwania, jednak treningi odbywały się codziennie. Komputerowy test szybkości reakcji oraz wybrane próby systemu wiedeńskiego zostały wykonane przed oraz po zakończeniu każdego cyklu treningowego. Zawodnicy wykonywali trening na podstawie protokołu beta1/theta przy użyciu oprogramowania Biograf Infiniti 6.0 oraz 5 – kanałowego urządzenia dekodującego ProComp5 z sensorem EEG. Wyniki. Szczegółowa analiza wyników pokazuje, że zastosowanie treningu biofeedback, który przyczynił się do poprawy szybkości reakcji, znacząco wpływa na dynamikę aktywności fal mózgowych. Wnioski. Trening neurofeedback u zawodników judo może prowadzić do polepszenia wyników związanych z poprawą szybkości reakcji. Konieczne są jednak dalsze badania na szerszej grupie zawodników.
Purpose of research. The aim of this study was to analyze the dynamics of the variability of the Theta and Beta waves in the experimental and control groups after successive biofeedback sessions, and to determine the optimal number of biofeedback training units to achieve the goal of the study, which was to improve the reaction speed in the experimental group. Method. 12 men, members of the national team of the Polish Judo Association took part in the study. The competitors participated in two training cycles. Each cycle consisted of 15 training sessions. The duration of the training was 4 minutes. In the first session, training was held every other day. The second series of tests, which took place after a four-week break, was characterized by the same duration, but the training was held every day. A computer test of reaction speed and selected tests of the Vienna system were carried out before and after each training cycle. The competitors performed the training based on the beta1 / theta protocol using the Biograf Infiniti 6.0 software and a 5-channel ProComp5 decoding device with an EEG sensor. Results. Analysis of the results shows that the application of biofeedback training, which contributed to the improvement of reaction speed, significantly affects the dynamics of brain wave activity. Conclusions. There has been great interest in research in delivering the importance of training the EEG-biofeedback in sport. There are many unresolved issues and inconsistent conclusions, which need to be explained. It is necessary to perform research in more cases and to determine the optimal training methodology, which will lead to the proposal of practical suggestions, taking into account individual disciplines and sports competitions.
Źródło:
Ogrody Nauk i Sztuk; 2019, 9; 388-399
2084-1426
Pojawia się w:
Ogrody Nauk i Sztuk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The added value of the electrical neuroimaging for the evaluation of marketing stimuli
Autorzy:
Vecchiato, G.
Toppi, J.
Astolfi, L.
Cincotti, F.
De Vico Fallani, F.
Maglione, A.G.
Borghini, G.
Cherubino, P.
Mattia, D.
Babiloni, F.
Powiązania:
https://bibliotekanauki.pl/articles/201578.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
EEG
neuromarketing
memory
attention
Opis:
There is a large interest in the marketing world to use the neuroimaging tools as a possible aid to evaluate the efficacy of a commercial advertisement. Such an area of study is called "neuromarketing". Here we illustrate some applications of electrical neuroimaging, a discipline using EEG and intensive signal processing techniques for the evaluation of such marketing stimuli. We will show which kind of information is possible to gather with these methodologies while persons are watching marketing relevant stimuli. Such information is related to the memorization and attention of commercial advertisements. We noted that temporal and frequency patterns of EEG signals are able to return descriptors of cognitive process in subjects that watched such commercial announcements. The described EEG methodologies could be then employed both to better design new products that are going to be promoted on the market as well as to analyse the global cognitive impact of commercial videos already broadcasted.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2012, 60, 3; 419-426
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ redukcji liczby elektrod w systemie BCI na ocenę aktywności elektrycznej mózgu
The impact of reducing the number of electrodes in the BCI system on evaluation of the brain electrical activity
Autorzy:
Oskwarek, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/155070.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
interfejs mózg-komputer
BCI
elektroencefalografia
EEG
aktywność mózgu
zagadnienie odwrotne EEG
Brain-Computer Interface
electroencephalography
brain activity
EEG inverse problem
Opis:
W artykule zaprezentowano wyniki analiz dotyczących aktywności elektrycznej mózgu ukierunkowanych na możliwość redukcji liczby elektrod w badaniu EEG wykonywanym na potrzeby asynchronicznego interfejsu mózg-komputer (BCI). Stosowne obliczenia potwierdzają zasadność wyboru zestawu 8 elektrod (tzn. F3, T7, C3, Cp1, C4, T8, F4 i Cz) w systemie BCI, wykorzystującym wyspecjalizowany wzmacniacz EEG firmy g.tec, skonstruowanym w IETiSIP Politechniki Warszawskiej.
The subject of the paper is evaluation of the brain electrical activity associated with imagining some specific motor actions for the needs of asynchronous Brain-Computer Interface (BCI) [1-4]. These analysis, called EEG inverse problems, can be useful among others to optimize the number and placement of electrodes. Dedicated calculations were carried out using the algorithm sLORETA (Section 3) [5-13]. The basis of the BCI interface is the ability to detect differences between the considered classes of tasks. In the case of asynchronous interfaces, the evaluation of brain activity in the frequency domain provides much more conclusive information than the time-domain analysis. These indicate that, although the best conditions for synchronous neuronal activity are in the range of delta waves (up to 4 Hz), the biggest differences between the compared classes are apparent in the alpha band (8-12 Hz) in the central parts of the cortex (Section 5; pic. 2,3). Moreover, the performed calculations show no significant difference in the location of the brain activity sources for the results obtained using the set of 32 electrodes and after the fourfold reduction in the number of electrodes. Thus, they confirm the relevance of the set of 8 electrodes (i.e. F3, T7, C3, CP1, C4, T8, F4, and Cz) in the BCI system constructed and used in the Department of Information and Measuring Systems of the Warsaw University of Technology (Sections 6,7; Fig. 5; Tab. 2).
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 9, 9; 718-721
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza możliwości wykorzystania wirtualnej rzeczywistości do badania reakcji na bodźce
Analysis of possibility of virtual reality usage for investigating reaction on given conditions
Autorzy:
Łukasiak, Marcin
Machul, Kamil
Maj, Mateusz
Powiązania:
https://bibliotekanauki.pl/articles/98356.pdf
Data publikacji:
2019
Wydawca:
Politechnika Lubelska. Instytut Informatyki
Tematy:
emocje
VR
EEG
puls
emotions
Opis:
Badanie miało na celu sprawdzenie możliwości wykorzystania technologii VR w celu wywołania konkretnych emocjiu badanego. Przeprowadzone badania literaturowe wykazały wysokie prawdopodobieństwo uzyskania pomyślnych wyników, jednak dotychczas badania opierane były na pomiarach uzyskanych przy użyciu wyspecjalizowanego, drogiego sprzętu. Niniejsza praca miała wykazać, że uzyskanie podobnych rezultatów jest możliwe również z wykorzystaniem budżetowych rozwiązań. Uzyskane wyniki pozwalają stwierdzić, że nawet korzystając z mało wyszukanych technologii można uzyskać zadowalające rezultaty, które mogą określić wpływ obrazu wyświetlanego w goglach na emocje badanego.
The study was tend to checking the possibility of using VR technology to invoke specific emotions on the subject. Literature studies have shown a high probability of obtaining successful results, but so far studies have been based on measurements obtained using specialized, expensive equipment. This study was about to show that obtaining similar results is also possible with usage of low budget solutions. Received results allow to conclude even using the less sophisticated technology, satisfactory results can be gained, which can determine the effect of the image displayed in the goggles on the emotions of the subject.
Źródło:
Journal of Computer Sciences Institute; 2019, 12; 179-186
2544-0764
Pojawia się w:
Journal of Computer Sciences Institute
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Możliwości zastosowania terapii infradźwiękowej w leczeniu zaburzeń snu
Possibility of application of infrasound therapy in treatment of sleep disorders
Autorzy:
Kasprzak, C.
Powiązania:
https://bibliotekanauki.pl/articles/261278.pdf
Data publikacji:
2009
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
sen
infradźwięki
EEG
sleep
infrasound
Opis:
W pracy przedstawiono rozważania nad możliwością zastosowania infradźwięków, w celu poprawy jakości snu. Przesłanką do sformułowania i podjęcia wstępnych hipotez są wyniki uzyskane z badań nad wpływem fal akustycznych niskich częstotliwości na zmiany w morfologii sygnału EEG.
In this paper, the possibility of application of infrasounds in sleep disorders, is discussed. The reason to perform such study is based on the results of examinations on the influence of low frequency acoustic waves on alterations of EEG signals morphology.
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2009, 15, 4; 390-392
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A mobile system for measurements of partial discharges controlled by electroencephalographic waves
Autorzy:
Błachowicz, A.
Paszkiel, Sz.
Powiązania:
https://bibliotekanauki.pl/articles/384381.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
EEG
mobile robot
partial discharges
Opis:
The article presents the concepts of a mobile system for measurements of partial discharges controlled by brain waves. In order to describe that, a robot, which takes measurements of partial discharges, has been worked out. The discharges may occur in an isolator of electrical devices such as capacitors and transformers. What is more, a concept of a link between the robot and a human brain is described, in order to ensure a direct communication on the level of the human brain and the robot.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2010, 4, 3; 31-35
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of Psychoacoustic Annoyance on EEG Signals of Tractor Drivers
Autorzy:
Lashgari, Majid
Arab, Mohammad Reza
Nadjafi, Mohsen
Rafiee, Mojtaba
Powiązania:
https://bibliotekanauki.pl/articles/31339953.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
EEG
Higuchi
fractal
tractor
sound.
Opis:
The purpose of this study was to evaluate the psychoacoustic annoyance (PA) that the tractor drivers are exposed to, and investigate its effects on their brain signals during their work activities. To this aim, the sound of a garden tractor was recorded. Each driver’s electroencephalogram (EEG) was then recorded at five different engine speeds. The Higuchi method was used to calculate the fractal dimension of the brain signals. To evaluate the amount of acoustic annoyance that the tractor drivers were exposed to, a psychoacoustic annoyance (PA) model was used. The results showed that as the engine speed increased, the values of PA increased as well. The results also indicated that an increase in the Higuchi’s fractal dimension (HFD) of alpha and beta bands was due to the increase of the engine speed. The regression results also revealed that there was a high correlation between the HFD of fast wave activities and PA, in that, the coefficients of determination were 0.92 and 0.91 for alpha and beta bands, respectively. Hence, a good correlation between the EEG signals and PA can be used to develop a mathematical model which quantifies the human brain response to the external stimuli.
Źródło:
Archives of Acoustics; 2022, 47, 4; 469-477
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Niedrgawkowy stan padaczkowy u dorosłych
Autorzy:
Bosak, Magdalena
Powiązania:
https://bibliotekanauki.pl/articles/551635.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Przyjaciół Medycyny Rodzinnej i Lekarzy Rodzinnych
Tematy:
padaczka
niedrgawkowy stan padaczkowy
EEG
Źródło:
Family Medicine & Primary Care Review; 2015, 4; 299-305
1734-3402
Pojawia się w:
Family Medicine & Primary Care Review
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transition of emotions from the negatively excited state to positive unexcited state: an ERP perspective
Autorzy:
Singh, Moon Inder
Singh, Mandeep
Powiązania:
https://bibliotekanauki.pl/articles/2106415.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
EEG
emotion
emotion transition
arousal
valence
Opis:
The cognitive aspects like perception, problem-solving, thinking, task performance, etc., are immensely influenced by emotions making it necessary to study emotions. The best state of emotion is the positive unexcited state, also known as the HighValence LowArousal (HVLA) state of the emotion. The psychologists endeavour to bring the subjects from a negatively excited state of emotion (Low Valence High Arousal state) to a positive unexcited state of emotion (High Valence Low Arousal state). In the first part of this study, a four-class subject independent emotion classifier was developed with an SVM polynomial classifier using average Event Related Potential (ERP) and differential average ERP attributes. The visually evoked Electroencephalogram (EEG) signals were acquired from 24 subjects. The four-class classification accuracy was 83% using average ERP attributes and 77% using differential average ERP attributes. In the second part of the study, the meditative intervention was applied to 20 subjects who declared themselves negatively excited (in Low Valence High Arousal state of emotion). The EEG signals were acquired before and after the meditative intervention. The four-class subject independent emotion classifier developed in Study 1 correctly classified these 20 subjects to be in a negatively excited state of emotion. After the intervention, 16 subjects self-assessed themselves to be in a positive unexcited (HVLA) state of emotion (which shows the intervention accuracy of 80%). Testing a four-class subject independent emotion classifier on the EEG data acquired after the meditative intervention validated 13 of 16 subjects in a positive unexcited state, yielding an accuracy of 81.3%.
Źródło:
Metrology and Measurement Systems; 2022, 29, 2; 405--423
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Displaced Dispositif
Autorzy:
Edmonds, Guy
Lewin, Shaun
Powiązania:
https://bibliotekanauki.pl/articles/632525.pdf
Data publikacji:
2017
Wydawca:
Projekt Avant
Tematy:
early cinema
EEG
flicker
performance
sonification
Opis:
“Dispositif” is a term used in film studies since the 1970s to describe the entire system of mechanical and human factors which together bring about the cinema experience. It therefore refers to (amongst other things) the space of the auditorium, the screen, the projection technology and the physiology of the spectator. Many of its qualifying components are masked from the view of participants in the system. The dispositif’s purpose is to set up the conditions for a specific type of cognitive experience, one which mirrors and extends (and in some readings, controls) the experience of its participants.The Displaced Dispositif is a performance designed for the space of a cinema theatre, but featuring the projection of fragments of early silent cinema on a coeval (1910s) film projector from the auditorium. The film fragments are live-scored by the sound artist, Shaun Lewin, using a combination of closely mic’d sources on the projector itself, luminance data from the projected image and EEG brainwave data recorded from participants during previous projections of the film. Displacing elements in the dispositif in this way, by shifting modalities, situating in parallel, feeding back and layering, draws attention to its hidden existence and creates the potential for a more knowing and informed participation in the cinema experience. It also serves to demonstrate the degree to which dispositifs of modern cinema spectatorship, which have morphed and proliferated since the widespread digitization of film heritage, have radically altered both the technological and experiential qualities of the medium. By integrating EEG data, the performance adds the dimension of electrophysiological experience to the long tradition within experimental cinema of artists calling attention to Cinema’s hidden structures. As well as challenging the dominance of the worldview propagated by the film industry, the performance also signals a means of re-engaging with the creative potential of the system itself, once unshackled from its bonds to the reality effect and freed from the limits imposed by its commercializing instincts.
Źródło:
Avant; 2017, 8
2082-6710
Pojawia się w:
Avant
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Warped s-transform for analysing the brain waves
Spaczona transformata s do analizy fal mózgowych
Autorzy:
Borowicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/88398.pdf
Data publikacji:
2014
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
WDFT
transformata S
EEG
Stockwell transform
Opis:
In this paper the warped S-transform is introduced as a tool for non-uniform time-frequency representation (TFR) of the brain electrical activity. The brain oscillations are classified as the five basic rhythms. The center frequencies and frequency ranges of these rhythms are non-uniformly distributed over frequency scale. Unlike the conventional S-transform the proposed technique is based on the warped discrete Fourier transform (WDFT), that allows for frequency scale warping. This can improves a spectral resolution of the TFR in particular oscillation band. In opposition to the time-domain filtering techniques, the brain rhythms can be analysed more precisely in the time-frequency plane as a full-band signal.
W artykule wprowadzamy spaczoną transformatę S, jako narzędzie nierównomiernej reprezentacji czasowo-częstotliwościowej aktywności elektrycznej mózgu. Oscylacje mózgowe klasyfikowane są, jako pięć podstawowych rytmów. Częstotliwości środkowe oraz zakresy odpowiadające tym rytmom rozmieszczone są nierównomiernie na skali częstotliwości. Proponowana technika, w przeciwieństwie do konwencjonalnej transformaty S, opiera się na spaczonej dyskretnej transformacie Fouriera, która pozwala na deformowanie skali częstotliwości. Umożliwia to zwiększenie rozdzielczości widmowej reprezentacji czasowo-częstotliwościowej w określonym pasmie oscylacji. W odróżnieniu od klasycznych metod filtracji dziedziny czasu, rytmy mózgowe mogą być dokładniej analizowane w płaszczyźnie czasowo-częstotliwościowej, jako sygnał pełno-pasmowy.
Źródło:
Advances in Computer Science Research; 2014, 11; 5-16
2300-715X
Pojawia się w:
Advances in Computer Science Research
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies