Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "CO2 storage" wg kryterium: Temat


Tytuł:
CO2 storing capacity in geologic formations in the Czech Republic
Autorzy:
Bujok, P.
Klempa, M.
Labus, K.
Porzer, M.
Panek, P.
Rado, R.
Gonzalez-Rodriguez, M.
Powiązania:
https://bibliotekanauki.pl/articles/299299.pdf
Data publikacji:
2015
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
CO2 storage
CO2 storage in geologic formations in the Czech Republic
boreholes for CO2 storage
modelling of CO2 storage
laboratory methods for CO2 storage
Opis:
The CO2 emission is a significant environmental problem threatening the sustained development of mankind. One of the possible ways of limiting the emission is the disposal of carbon dioxide in geologic formations.A pilot project of CO2 storage in geologic formations in the Czech Republic (REPP-CO2) is presented in this paper. The project is part of the Norwegian Fund and the research consortium (headed by the Czech Republic Geologic Office), with VSB-TU Ostrava as a participant. The VSB-TU Ostravais represented by the Faculty of Geology and Mining (HGF) and the Faculty of Metallurgy and Materials Science (FMMI) in the consortium.The research activity of the consortium mainly focuses on the development and improvement of selected laboratory methods, modelling and simulation, which are basic for the evaluation of safety of CO2 storing in geologic forma-tions. Thise paper presents the research conducted by the Faculty of Geology and Mining (HGF) VSB-TU Ostrava within the project.
Źródło:
AGH Drilling, Oil, Gas; 2015, 32, 4; 683-692
2299-4157
2300-7052
Pojawia się w:
AGH Drilling, Oil, Gas
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Geologiczne składowiska CO2 fabrykami metanu?
Geological CO2 storage - methane producing factories?
Autorzy:
Wójcicki, A.
Brochwicz-Lewiński, W.
Powiązania:
https://bibliotekanauki.pl/articles/2066171.pdf
Data publikacji:
2009
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
gaz ziemny
składowiska CO2
gas
CO2 storage
Źródło:
Przegląd Geologiczny; 2009, 57, 12; 1042-1045
0033-2151
Pojawia się w:
Przegląd Geologiczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
CO2 storage capacity of a deep aquifer depending on the injection well location and cap rock capillary pressure
Pojemność składowania CO2 w głębokich poziomach wodonośnych w zależności od lokalizacji otworu zatłaczającego oraz ciśnienia kapilarnego nieprzepuszczalnego nadkładu
Autorzy:
Luboń, Katarzyna
Powiązania:
https://bibliotekanauki.pl/articles/216776.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
CO2 storage
saline aquifer
CO2 capacity
CO2 storage safety
składowanie CO2
poziom wodonośny
pojemność CO2
bezpieczeństwo składowania CO2
Opis:
Using the Konary anticlinal structure in central Poland as an example, a geological model has been built of the Lower Jurassic reservoir horizon, and CO2 injection was simulated using 50 various locations of the injection well. The carbon dioxide storage dynamic capacity of the structure has been determined for the well locations considered and maps of CO2 storage capacity were drawn, accounting and not accounting for cap rock capillary pressure. Though crucial for preserving the tightness of cap rocks, capillary pressure is not always taken into account in CO2 injection modeling. It is an important factor in shaping the dynamic capacity and safety of carbon dioxide underground storage. When its acceptable value is exceeded, water is expelled from capillary pores of the caprock, making it permeable for gas and thus may resulting in gas leakage. Additional simulations have been performed to determine the influence of a fault adjacent to the structure on the carbon dioxide storage capacity. The simulation of CO2 injection into the Konary structure has shown that taking capillary pressure at the summit of the structure into account resulted in reducing the dynamic capacity by about 60%. The greatest dynamic capacity of CO2 storage was obtained locating the injection well far away from the structure’s summit. A fault adjacent to the structure did not markedly increase the CO2 storage capacity. A constructed map of CO2 dynamic storage capacity may be a useful tool for the optimal location of injection wells, thus contributing to the better economy of the enterprise.
Na przykładzie antyklinalnej struktury Konary w centralnej Polsce zbudowano model geologiczny dolnojurajskiego poziomu zbiornikowego oraz przeprowadzono symulację zatłaczania CO2 50 różnymi lokalizacjami otworu zatłaczającego. Wyznaczono pojemność dynamiczną składowania dwutlenku węgla struktury dla rozpatrywanych otworów oraz opracowano mapy pojemności składowania CO2 bez uwzględniania oraz przy uwzględnieniu ciśnienia kapilarnego. Chociaż odgrywa istotną rolę w utrzymaniu szczelności nadkładu, ciśnienie kapilarne nie zawsze jest uwzględniane w modelowaniu zatłaczania CO2. Jest istotnym czynnikiem wpływającym na pojemność dynamiczną oraz bezpieczeństwo podziemnego składowania dwutlenku węgla. Przekroczenie jego dopuszczalnej wartości powoduje wyparcie wody z kapilar nadkładu, który staje się przepuszczalny dla gazu, co w konsekwencji może prowadzić do wycieku gazu. Wykonano dodatkowe symulacje w celu określenia, w jakim stopniu uskok w pobliżu struktury wpływa na pojemność dynamiczną dwutlenku węgla. Wyniki symulacji zatłaczania CO2 do struktury Konary pokazały, że uwzględnienie ciśnienia kapilarnego w szczycie struktury wpłynęło na obniżenie pojemności dynamicznej o około 60%. Największą pojemność dynamiczną składowania CO2 otrzymano, lokując otwór z dala od szczytu struktury. Obecność uskoku w sąsiedztwie struktury nie przyczyniła się znacząco do zmiany pojemności dynamicznej składowania dwutlenku węgla w tej strukturze. Mapa pojemności dynamicznej składowania CO2 może być pomocnym narzędziem do wyboru optymalnych miejsc do zatłaczania tego gazu, przyczyniając się do podniesienia ekonomiki przedsięwzięcia.
Źródło:
Gospodarka Surowcami Mineralnymi; 2020, 36, 2; 173-196
0860-0953
Pojawia się w:
Gospodarka Surowcami Mineralnymi
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Potential application of CO2 for enhanced condensate recovery combined with geological storage in the depleted gas-condensate reservoirs
Autorzy:
Burachok, Oleksandr
Nistor, Mariana Laura
Sosio, Giovanni
Kondrat, Oleksandr
Matkivskyi, Serhii
Powiązania:
https://bibliotekanauki.pl/articles/1536919.pdf
Data publikacji:
2021
Wydawca:
STE GROUP
Tematy:
gas-condensate
EOR
EGR
CO2 storage
Opis:
CO2 emissions are considered to be the main contributor to global warming and climate change. One of the ways reducing the emissions to atmosphere is a proper capture and further geological storage of the carbon dioxide. In the oil industry, CO2 is used as one of the injection agents to displace oil and enhance its recovery. Due to the low multi-contact miscibility pressure between CO2 and hydrocarbons, fully miscible condition is quickly reached, leading to efficient displacement and high recovery factors. The utilization of the depleted gas fields for CO2 storage, however, is considered as the option that is more expensive compared to oil field, since the enhanced recovery of gas with CO2 is not effective. For this reason, our study considers the potential use of CO2 EOR in depleted gas-condensate fields. This potential is evaluated by performing numerical simulations for the typical-size gascondensate reservoirs with no active aquifer, in order to estimate both the storage efficiency and the additional oil recovery from condensed C5+ hydrocarbon fractions, that otherwise will be never recovered and lost in the reservoir. Obtained results indicate significant potential for CO2 storage and additional condensate recovery from the typical gas-condensate field of Eastern Ukraine.
Źródło:
Management Systems in Production Engineering; 2021, 2 (29); 106-113
2299-0461
Pojawia się w:
Management Systems in Production Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of possibilities of CO2 geosequestration in geological structures of the Czech Republic
Oszacowanie możliwości geosekwestracji CO2 w strukturach geologicznych Republiki Czech
Autorzy:
Bujok, P.
Nemec, P.
Nemec, J.
Konecny, P.
Powiązania:
https://bibliotekanauki.pl/articles/300562.pdf
Data publikacji:
2009
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
dwutlenek węgla
magazyny CO2
carbon dioxide
CO2 storage
Opis:
The present-day emissions of carbon dioxide (CO2) generated by anthropogenic activities and the expected future growing production of them are even now a serious ecological problem. One of possibilities of solving this situation is CO2 storage, i.e. the building of CO2 storage sites in suitable parts of the rock mass. They are represented, in addition to ideal localities, which are mined-out deposits of natural gas and oil, by selected geological formations of sedimentary Carboniferous deposits of hazd coal, it means localities of closed underground hard coal mines provided that they are ''tight'' enough. For the purposes of CO2 geosequestration, theoretically all closed hard coalfields exploited using the underground method in the Czech Republic can be considered, namely the Rosice-Oslavany (RUD), Kladno, Zacler-Svatonovice and Most Coalfields, and partial localities (closed mines) in the Czech part of Upper Silesian Hard Coal Basin (Ostrava-Karvina Coalfield). Of hydrocarbon deposits situated especially in the Vienna Basin, the Poddvorov, Nitkovice, Kostelany-vychod and Zdanice-zapad structures seem to be most promising.
Obecne emisje dwutlenku węgla (CO2) pochodzenia antropogenicznego oraz przewidywany w przyszłości ich wzrost nadal stanowią problem ekologiczny. Jednym ze sposobów rozwiązania tego problemu jest magazynowanie CO2 tzn. budowanie miejsc magazynowania CO2 w nadających się do tego częściach górotworu. Należą do nich takie idealne miejsca, jak wyeksploatowane przestrzenie po produkcji gazu ziemnego i ropy naftowej, jak również niektóre formacje geologiczne, np. skały osadowe Karbonu z wyeksploatowanymi i odpowiednio szczelnymi złożami węgla kamiennego. Geosekwestracja CO2 wykonywana jest w zasadzie na wszystkich czeskich złożach węgla kamiennego eksploatowanych metodą podziemną, tj. Rosice-Oslavany (RUD), Kladno, Zacler-Svatonovice, w większości złóż, jak również w częściowo zlikwidowanych kopalniach czeskiej części Górnośląskiego Zagłębia Węglowego (Ostrava-Karvina). Spośród złóż zlokalizowanych w Basenie Wiedeńskim, najbardziej obiecujące wydają się być złoża Poddvorov, Nitkovice, Kostelany-vychod i Zdanice-zapad.
Źródło:
Wiertnictwo, Nafta, Gaz; 2009, 26, 1--2; 107-117
1507-0042
Pojawia się w:
Wiertnictwo, Nafta, Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Leaching of mersin/aydincik dolomite ore in hydrochloric acid. Dissolution rates
Autorzy:
Altiner, M.
Yildirim, M.
Yilmaz, T.
Powiązania:
https://bibliotekanauki.pl/articles/110873.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
dolomite leaching
CO2 storage
fractional life method
Opis:
In this paper dissolution of dolomite ore, collected from Mersin/Aydincik in Turkey, was investigated under various experimental conditions in the presence of HCl acid. Particle size, acid/dolomite ratio, solid/liquid ratio, stirring speed, reaction time and temperature were also conducted to the determin the optimum experimental conditions. During the experiment, CO2 amount released from the dolomite was measured through the experimental apparatus to determine reaction orders and rate constants of the sample at the different temperatures by using the fractional life approach method. It was found that, reaction orders and rate constants, based on temperatures, changed from 1.505 to 1.339 and between 3.17 and 10.49 10–2 mol dm–3 sec–1 respectively. In addition, differences in reaction rate constants were examined with the Arrhenius equation and activation energy of the dissolution process was calculated as 16.69 kJ mol–1, which was consistent with the activation energies determined in literature.
Źródło:
Physicochemical Problems of Mineral Processing; 2016, 52, 2; 536-550
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Perspektywiczne kompleksy do składowania CO2 w podłożu Karpat zewnętrznych i zapadliska przedkarpackiego pomiędzy Krakowem a Rzeszowem
The prospective complexes for CO2 storage in the basement of the Carpathian Foredeep between Cracow and Rzeszów
Autorzy:
Chowaniec, J.
Buła, Z.
Habryn, R.
Ryłko, W.
Tomaś, A.
Powiązania:
https://bibliotekanauki.pl/articles/2062899.pdf
Data publikacji:
2012
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
technologia CCS
magazyny CO2
podłoże Karpat
CCS technology
CO2 storage
Carpathians bedrock
Opis:
W artykule przedstawiono analizę możliwości składowania dwutlenku węgla na obszarze obejmującym strefę Karpat zewnętrznych i zapadlisko przedkarpackie na obszarze między Krakowem a Rzeszowem. W wyniku przeprowadzonej analizy budowy geologicznej za potencjalne skały zbiornikowe do składowania CO2 uznano występujące na tym obszarze: gruboklastyczne utwory kambru dolnego, węglanowe osady dewonu środkowego i górnego oraz karbonu dolnego, a także permsko-triasowe i środkowojurajskie piaskowce i zlepieńce. Uwzględniając ogólnie przyjęte kryteria przy typowaniu struktur i formacji do geologicznego składowania CO2, wyróżniono cztery rejony występowania skał zbiornikowych. Podobszar A — zbiornik Wadowice–Myślenice o powierzchni około 850 km2, w którym jako potencjalny zbiornik do składowania CO2 wytypowano kompleks dolnokambryjskich skał piaskowcowo-zlepieńcowych. Podobszar B — zbiornik Gdów o powierzchni 765,5 km2, skałę zbiornikową stanowią tu piaskowce i zlepieńce permo-triasu i jury środkowej. Podobszar C — zbiornik Niepołomice o powierzchni 268,9 km2, skałę zbiornikową stanowią dewońskie wapienie i dolomity. Podobszar D — zbiornik Grobla. Obszar proponowanego zbiornika obejmuje 422,4 km2, skałę zbiornikową stanowią dewońsko-dolnokarbońskie wapienie i dolomity. Poziom uszczelniający dla skał zbiornikowych w wymienionych rejonach stanowią utwory mioceńskie zapadliska przedkarpackiego, tworzące na analizowanym obszarze zwartą pokrywę, o zróżnicowanej miąższości przekraczającej 100 m. W części południowej obszaru na te utwory są nasunięte jednostki fliszowe Karpat.
The paper deals with the possibility of carbon dioxide storage in the Outer Carpathians and the Carpathian Foredeep between Kraków and Rzeszów. The analysis of the geological structure has revealed the following potential reservoir rocks for CO2 storage: coarse-clastic Cambrian rocks, Middle and Upper Devonian and Lower Carboniferous carbonates, and Permian-Triassic and Middle Jurassic sandstones and conglomerates. Four sub-areas of reservoir rocks have been indicated for the geological storage of CO2: (1) Sub-area A – the Wadowice–Myślenice reservoir with a surface area of about 850 km2 as a potential reservoir for CO2 represented by a Lower Cambrian sandstone-conglomerate rock complex; (2) Sub-area B – the Gdów reservoir with a surface area of 765.5 km2, where the reservoir rocks are Permian-Triassic and Middle Jurassic sandstones and conglomerates; (3) Sub-area C – the Niepołomice reservoir with a surface area of 268.9 km2, with the reservoir rocks composed by Devonian carbonates and dolomites; (4) Sub-area D – the Grobla reservoir with a surface area of 422.4 km2, represented by Devonian–Lower Carboniferous carbonates and dolomites. The cap rocks for the reservoir rocks in these areas are the Miocene formations of the Carpathian Foredeep, forming a compact cover with a variable thickness exceeding 100 m. In the southern part of the area, these formations are overthrust by the Flysch formations of the Outer Carpathians.
Źródło:
Biuletyn Państwowego Instytutu Geologicznego; 2012, 448 (1); 57--70
0867-6143
Pojawia się w:
Biuletyn Państwowego Instytutu Geologicznego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Innowacyjne technologie wychwytu, składowania oraz utylizacji CO2
Autorzy:
Bator, Jakub
Powiązania:
https://bibliotekanauki.pl/articles/31804072.pdf
Data publikacji:
2022
Wydawca:
Nowa Energia
Tematy:
wychwyt CO2
składowanie CO2
utylizacja CO2
dekarbonizacja
CO2 capture
CO2 storage
CO2 utilization
decarbonization
Opis:
W ostatnich latach można zauważyć znaczny wzrost rozwoju ekonomicznego na całym świecie. Naturalnym następstwem tego jest zwiększone zapotrzebowanie na energię, czego konsekwencją jest zużywanie większych ilości paliw, a w szczególności paliw kopalnych, które stanowią główne źródło energii. Efektem tego jest zdecydowany wzrost emisji gazów cieplarnianych, a zwłaszcza ditlenku węgla, który jest uważany za główne źródło powstawania efektu cieplarnianego. Z tego względu dekarbonizacja systemu energetycznego jest jednym z kluczowych elementów dla realizacji postawionych przez UE celów klimatycznych, gdzie jednym z głównych założeń jest osiągnięcie neutralności klimatycznej pod względem emisji ditlenku węgla (CO2) do 2050 r.
Źródło:
Nowa Energia; 2022, 5/6; 4-6
1899-0886
Pojawia się w:
Nowa Energia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wstępna geologiczna analiza struktur do składowania CO2 w rejonie Bełchatowa
Preliminary geological analysis of structures to store CO2 within the Bełchatów area
Autorzy:
Tarkowski, R.
Marek, S.
Uliasz-Misiak, B.
Powiązania:
https://bibliotekanauki.pl/articles/217004.pdf
Data publikacji:
2009
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
składowanie CO2
struktura geologiczna
poziomy wodonośne
Polska
CO2 storage
geological structure
aquifer
Polska
Opis:
Przedstawiono wyniki wstępnej analizy geologicznej struktur w mezozoicznych solankowych poziomach (dolnej kredy, dolnej jury oraz dolnego i górnego triasu) Niżu Polskiego do składowania CO2 w rejonie Bełchatowa. Na podstawie kryteriów przedstawionych w "Best pratice for the storage of CO2 in saline aquifers" z modyfikacjami autorów wskazano 6 struktur w 5 lokalizacjach (antyklina Jeżowa, rów Kliczkowa, antyklina Lutomierska, antyklina Tuszyna i antyklina Zaosia). Przedmiotem analizy była: pojemność składowania CO2, głębokość poziomu zbiornikowego, jego miąższość efektywna, porowatość, przepuszczalność, mineralizacja, obecność uskoków oraz miąższość skał nadkładu. Przyjęto, że odległość struktury geologicznej od elektrowni w Bełchatowie nie przekroczy 80 km, a minimalną pojemność struktury założono na poziomie 60 Mt. Obliczeń pojemności wolumetrycznej struktur dokonano w ujednoliconej metodyce przyjętej w projekcie EU GeoCapacity. Wytypowane i wstępnie scharakteryzowane struktury spełniają w różnym stopniu kryteria miejsc składowania dwutlenku węgla. Mogą one stanowić podstawę wyboru najlepszych i najodpowiedniejszych z nich dla szczegółowego rozpoznania możliwości geologicznego składowania dwutlenku węgla dla elektrowni Bełchatów.
Results of a preliminary geological analysis on CO2 storage suitability of geological structures of Mesozoic brine aquifers [Lower Cretaceous, Lower Jurassic, Lower and Upper Triassic] of the Polish Lowlands at the Bełchatów area were presented. According to criteria given in the "Best practice for the storage of CO2 in saline aquifers", with some authors' alterations, six structures in five locations were defined [the Jeżów anticline, the Kliczków trough, the Lutomierska anticline, the Tuszyn anticline, the Zaosie anticline]. Analysis covered: CO2 storage capacity, reservoir depth, its effective thickness, porosity, permeability, mineralization, fault occurrence, overburden thickness. It was assumed that the distance between geological structure and the Bełchatów Power Plant is less or equal to 80 km, while the minimum structure's capacity was assumed at 60 Mt. Calculations of volumetric capacity of structures were performed according to the unified methodology accepted at the GeoCapacity EU Project. Selected and preliminarily defined structures meet to a certain degree criteria of carbon dioxide storage locations. They might form base to select the best and the most suitable of them to recognize in detail geological carbon dioxide storage possibilities for the Bełchatów power plant.
Źródło:
Gospodarka Surowcami Mineralnymi; 2009, 25, 2; 37-45
0860-0953
Pojawia się w:
Gospodarka Surowcami Mineralnymi
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The possibilities of underground CO2 storage in the Zaosie Anticline
Możliwości wykorzystania antykliny Zaosia do podziemnego składowania CO2
Autorzy:
Marek, S.
Dziewińska, L.
Tarkowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/217054.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
składowanie CO2
struktura geologiczna
poziomy wodonośne
Polska
CO2 storage
geological structure
aquifer
Polska
Opis:
The Zaosie Anticline is located not far from Łódź and Bełchatów. It is one of the most interesting geological structures for underground CO2 storage in Poland and thus it requires a detailed study. The paper presents the geological characteristics of the Zaosie Anticline against the background of the geological structure of the region as well as the potential aquifers for CO2 storage, including their suitability for CO2 storage. The Zaosie Anticline was examined by seismic profiles and four deep boreholes. The following formations suitable for underground CO2 storage were analysed: Lower Jurassic Borucice and Komorowo formations and Lower Triassic Baltic Formation. The primary aquifer for CO2 storage in the Zaosie Anticline is the Baltic Formation of Scythian age. The secondary aquifer is the Upper Pliensbachian Komorowo Formation. The primary Lower Triassic aquifer was surveyed by three deep boreholes. Its volumetric storage capacity is approximately 340 million tons, and the TDS content in the formation water reaches 250g/dcm3. The aquifer is sealed directly by a thick series of clay-carbonate evaporite rocks and a thick packet of Middle and Upper Triassic and Jurassic deposits. Its disadvantage is a considerable depth to this level, which affects the petrophysical characteristics of reservoir rocks. The secondary aquifer, the Komorowo Formation, shows better petrophysical parameters of rocks in terms of CO2 storage, the depth to the aquifer is adequate, but its disadvantage is a low content of TDS in the formation water and the likelihood of contact with surface waters. The Borucice Formation aquifer is not recommended for CO2 storage because it occurs at a small depth and possibly contacts with meteoric waters. The Zaosie structure is of interest to the Bełchatów Power Station. Relatively near the structure (up to 50 km) are also the Dalkia Łódź ZEC SA plants, and the following plants are located a little further (up to 100 km): KCW Warta SA, Kozienice Power Plant SA, ZE PAK SA (Power Plant Group Company, Adamów), Vattenfall Heat Poland SA - (Siekierki and Żeran in Warsaw) and LaFarge Cement Poland SA (Małogoszcz).
Antyklina Zaosia znajduje się w bliskiej odległości od Łodzi i Bełchatowa i jest jedną z bardziej interesujących struktur geologicznych do składowania CO2 w Polsce, dlatego też dokonano szczegółowego jej opracowania. Przedstawiono charakterystykę geologiczną antykliny Zaosia na tle budowy geologicznej regionu, szczegółową budowę geologiczną, charakterystykę potencjalnych poziomów do składowania CO2 oraz przydatność rozważanych poziomów zbiornikowych do podziemnego składowania dwutlenku węgla. Antyklina Zaosia została rozpoznana profilami sejsmicznymi i czterema głębokimi otworami wiertniczymi. Do składowania CO2 przeanalizowano poziomy zbiornikowe: dolnojurajskie (formacja borucicka i formacja komorowska) oraz dolnotriasowy (formacja Bałtycka). Pierwszoplanowym poziomem zbiornikowym dla składowania CO2 w antyklinie Zaosia jest poziom formacji bałtyckiej scytyku, natomiast drugoplanowym poziomem zbiornikowym jest poziom formacji komorowskiej górnego pliensbachu. Pierwszoplanowy dolnotriasowy poziom zbiornikowy został rozpoznany trzema głębokimi otworami, jego wolumetryczna pojemność składowania wynosi około 340 mln ton, a mineralizacja wód złożowych osiąga 250 g/dcm3. Jest on uszczelniony bezpośrednio grubym kompleksem skał ilasto-wapnisto-ewaporytowych oraz miąższym pakietem skał triasu środkowego i górnego oraz jury. Jego mankamentem jest znaczna głębokość, co wpływa ujemnie na cechy petrofizyczne skał zbiornikowych. Drugoplanowy poziom zbiornikowy formacji komorowskiej posiada lepsze parametry petrofizyczne skał pod kątem składowania CO2, ma odpowiednią głębokość zalegania, a jego mankamentem jest mała mineralizacja wód złożowych i prawdopodobieństwo kontaktu z wodami powierzchniowymi. Poziom zbiornikowy formacji borucickiej nie jest rekomendowany do składowania CO2 z uwagi na jego małą głębokość i możliwy kontakt z wodami infiltracyjnymi. Struktura Zaosia stanowi przedmiot zainteresowania Elektrowni w Bełchatowie. W bliskiej odległości (do 50 km) od niej znajdują się zakłady Dalkia Łódź ZEC SA, a w nieco dalszej (do 100 km): KCW Warta SA, Elektrownia Kozienice SA, Zespół Elektrowni PAK SA (Adamów), Vattenfall Heat Poland SA - (Siekierki i Żerań w Warszawie), LaFarge Cement Poland SA (Małogoszcz).
Źródło:
Gospodarka Surowcami Mineralnymi; 2011, 27, 4; 89-107
0860-0953
Pojawia się w:
Gospodarka Surowcami Mineralnymi
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Geologiczne składowanie ditlenku węgla (CCS) jest metodą bezpieczną : dowody geologiczne
Geological storage of carbon dioxide (CCS) is safe : geological evidence
Autorzy:
Pieńkowski, G.
Powiązania:
https://bibliotekanauki.pl/articles/2075363.pdf
Data publikacji:
2015
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
składowanie CO2
bezpieczeństwo
właściwości uszczelniające
chemostratygrafia
paleoklimatologia
CO2 storage
safety
seal properties
chemostratigraphy
palaeoclimatology
Opis:
CO2 capture and geological storage (CCS) should be implemented in Poland, if combustion of coal will remain as a main source of energy in Poland, and European Union climate policy requirements are to be met. Despite existing experience and number of existing operational projects worldwide, a common fear concerning safety of the onshore, large scale geological storage of CO2 still occurs. Because of that fear, some European countries substantially limited even demonstration CCS projects. However, opinions on the method's safety should be based on solid geological evidence, not fears. Herein I provide some evidence from the Lower Jurassic basin in Poland that the method is safe. The key issue is the geological integrity of a seal. High-resolution sequence stratigraphy verified by chemostratigraphical correlation based on 13C isotope correlation, proved that one of key seal formations, the lower Toarcian Ciechocinek formation composed of clayey-muddy rocks with sandstone intercalation, is integral in terms of its lithology and spatial extent over the larger part of the Polish basin and provides an excellent seal. Origin of such favourable properties is attributed to climatic conditions (supergreenhouse conditions on land) during the Toarcian Oceanic Anoxic Event and high sea level at that time. Moreover, similar conditions occurred for four times during the Early–Middle Jurassic times, creating another over-regional seal formations in the large parts of the Polish Mesozoic epicontinental basin. It can allow a tiered sequestration method, using several sequestrartion systems (reservoir-seal couples) one above another, thus allowing much more voluminous and effective storage of CO2 and methane (for economic purposes) in selected structures.
Źródło:
Przegląd Geologiczny; 2015, 63, 1; 48--54
0033-2151
Pojawia się w:
Przegląd Geologiczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Koszty geologicznego składowania CO2
Costs of CO2 geological storage and an exemplary analysis for a given emitter
Autorzy:
Uliasz-Misiak, B.
Tarkowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/394602.pdf
Data publikacji:
2009
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
składowanie CO2
wychwytywanie
koszty
projekt EU GeoCapacity
CO2 storage
capture
costs
EU GeoCapacity project
Opis:
Koszty geologicznego składowania CO2 obejmują trzy kluczowe elementy tej technologii: wychwytywanie (w tym sprężanie gazu), transport oraz składowanie. Uzależnione są od licznych czynników: ilości składowanego gazu, technologii wychwytywania, odległości źródła emisji od miejsca składowania, lokalizacji miejsca składowania, kosztów instalacji zatłaczania, charakterystyki zbiornika, zagospodarowania terenu i innych. Spośród trzech etapów wychwytywania, transportu i składowania, pierwszy z nich jest najbardziej kapitałochłonny. Wysokie koszty wychwytywania CO2 są dziś główną przeszkodą wprowadzenia geologicznego składowania dwutlenku węgla. Na podstawie literatury przedstawiono koszty wszystkich trzech etapów geologicznego składowania dwutlenku węgla. Scharakteryzowano koszty wychwytywania CO2 dla elektrowni i procesów przemysłowych, koszty sprężania i transportu, rurociągami i drogą morską, koszty składowania geologicznego oraz koszty całego systemu CCS (Carbon Dioxide and Storage). Podkreślono, że komercyjne działania związane z każdym z zasadniczych elementów CCS dostarczają podstaw dla oszacowania kosztów bieżących, jednak wielkość tych kosztów w przyszłości jest trudno przewidywalna. W ramach projektu EU GeoCapacity sporządzono model ekonomiczny dla przypadku składowania CO2 w strukturze Dzierżanowa z jednej z elektrociepłowni zlokalizowanej na terenie Warszawy. Rozważano jedno źródło emisji i jedno miejsce składowania dwutlenku węgla. Przy założeniu zatłaczania CO2 do struktury Dzierżanowa dwoma otworami z wydatkiem 1 Mt CO2/rok przez czas życia systemu sekwestracyjnego (30 lat) zostanie zatłoczone 51,98 Mt gazu. Antyklina zostanie wypełniona w 19,99% dwutlenkiem węgla. Największe oszacowane koszty związane są z wychwytywaniem dwutlenku węgla - 675 mln Euro, niższe ze sprężaniem - 61,27 mln Euro, ze składowaniem - 7,87 mln Euro, a najniższe z transportem - 2,24 mln Euro.
CO2 geological storage costs cover three key constituents of CCS technology: gas capture (and compression), transportation and storage. The costs depend on different factors as: gas amount, applied capture technology, distance between emission source and storage site, location of the storage site, injection installation costs, reservoir characteristics, land development plan and many others. Amongst the three stages: capture, transportation and storage, the first one is the most capital-intensive. Carbon dioxide capturing high costs hinder the most introducing geological storage of carbon dioxide. Basing on literature knowledge there were presented costs of all three stages of geological carbon dioxide storage. There were characterized costs of CO2 capture for power plants and other industrial processes, costs of compression and transportation, by pipelines and gas carriers, costs of geological storage and total costs of a CCS (Carbon Dioxide and Storage) system. It was stressed that commercial activities involving every principle CCS constituent bring base to estimate present costs, however forecasting on costs in future is mercurial. Within frames of the EU GeoCapacity Project there was elaborated an economic model of CO2 storage process within the Dzierżanowo structure for a combined heat and power plant of the Warsaw area. A single emission source was considered, as well as a single carbon dioxide storage location. Allowing CO2 injecting into the Dzierżanowo structure through two wells of productivity estimated at 1 Mt CO2 per year, for all the sequestration installation lifetime (30 years) 51.98 Mt of CO2 would be injected. The anticline would be filled with carbon dioxide in 19.99%. Top estimated costs involve carbon dioxide capturing 675 mln Euro, compression involves less 61.27 mln Euro, storage involves less 7.87 mln Euro, transportation involves the least 2.24mln Euro.
Źródło:
Zeszyty Naukowe Instytutu Gospodarki Surowcami Mineralnymi i Energią PAN; 2009, 75; 21-34
2080-0819
Pojawia się w:
Zeszyty Naukowe Instytutu Gospodarki Surowcami Mineralnymi i Energią PAN
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka geologiczna antykliny Kamionek (niecka płocka) -potencjalne składowisko CO2
The geological characteristics of the Kamionki Anticline (Płock Trough) - a potential CO2 storage site
Autorzy:
Marek, S.
Dziewińska, L.
Tarkowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/216517.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
struktura geologiczna
składowanie CO2
struktura Kamionki
poziomy wodonośne
CO2 storage
geological structure
Kamionki structure
aquifer
Opis:
Przedstawiono położenie, budowę geologiczną i charakterystykę struktury Kamionek pod kątem podziemnego składowania dwutlenku węgla. Leży ona na terenie niecki płockiej, w SW części bloku Płońska i jest ona przykładem rowu synsedymentacyjnego o założeniach wczesno- i środkowojurajskich. Została rozpoznana półszczegółowym zdjęciem sejsmiki refleksyjnej oraz trzema głębokimi otworami wiertniczymi (Kamionki 1, Kamionki 2 i Kamionki IG-3). Przyjmując umownie zarys antykliny wyznaczony izohipsą stropu jury dolnej, jej długość wynosi około 15 km, szerokość około 5 km i powierzchnia około 75 km2. Dane geologiczne, sejsmiczne i złożowe pozwalają stwierdzić, że struktura ta dobrze spełnia warunki stawiane miejscom podziemnego składowania dwutlenku węgla. Pierwszoplanowym poziomem zbiornikowym dla podziemnego składowania CO2 są utwory formacji mogileńskiej barremu-albu środkowego, o śmiąższości średnio 170 metrów, średnim udziale piaskowców 85%, porowatości około 20%, przepuszczalności powyżej 100 mD sięgającej do 2000 mD. Serię uszczelniającą stanowią margle, wapienie, opoki i kreda pisząca kredy górnej o miąższości około 1000 metrów. Drugoplanowym poziomem zbiornikowym są osady formacji borucickiej toarsu górnego. Struktura Kamionek jest jedną z dziewięciu struktur wytypowanych w utworach mezozoiku niecki płockiej do podziemnego składowania dwutlenku węgla. Znajduje się w niewielkiej odległości od dużego emitenta CO2 - PKN ORLEN SA (Płock), natomiast w odległości od 50-100 km znajdują się kolejni duzi emitenci (Vettenfall Heat Poland SA - Żerań, Soda Polska Ciech Sp. z o.o. - Janikowo i Inowrocław oraz Dalkia Łódź ZEC SA) mogący być zainteresowani geologicznym unieszkodliwianiem dwutlenku węgla.
The location, geological structure and characteristics of the Kamionki Anticline is presented in terms of possibility of underground CO2 storage. It is situated in the Płock Trough, in the SW part of the Płońsk Block, and represents a synsedimentary graben originated in the Early and Middle Jurassic. It has been explored by a semi-detailed reflection seismic survey and three deep boreholes (Kamionki 1, Kamionki 2 and Kamionki IG-3). Assuming that the anticline is conventionally outlined by a contour line of the top of the Lower Jurassic, its length is about 15 km, width is about 5 km and the area reaches approximately 75 km2. Geological, seismic and reservoir property data allow concluding that this structure is suitable for underground carbon dioxide storage. The primary reservoir level for underground CO2 storage is represented by Barremianmiddle Albian deposits of the Mogilno Formation with an average thickness of 170 metres, containing on the average 85% of sandstones, and showing porosity of about 20% and permeability above 100 mD up to 2000 mD. The sealing series is composed of Upper Cretaceous marls, limestones and chalk reaching the thickness of about 1000 metres. The secondary reservoir level is represented by upper Toarcian deposits of the Borucice Formation.
Źródło:
Gospodarka Surowcami Mineralnymi; 2011, 27, 2; 17-31
0860-0953
Pojawia się w:
Gospodarka Surowcami Mineralnymi
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Formacje i struktury solankowe perspektywiczne dla składowania CO2 w regionie Górnośląskiego Zagłębia Węglowego
Feasibility study of CO2 storage in saline formations and structures of the Upper Silesian Coal Basin
Autorzy:
Jureczka, J.
Chećko, J.
Krieger, W.
Warzecha, R.
Powiązania:
https://bibliotekanauki.pl/articles/2062838.pdf
Data publikacji:
2012
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
składowanie CO2
poziomy solankowe
Górnośląskie Zagłębie Węglowe
CO2 storage
saline aquifers
Upper Silesian Coal Basin
Opis:
W artykule przedstawiono ocenę możliwości lokalizacji składowisk CO2 w poziomach solankowych regionu Górnośląskiego Zagłębia Węglowego. Na podstawie analizy budowy geologicznej oraz oceny parametrów zbiornikowych, jako potencjalne składowiska wyznaczono trzy poziomy solankowe: dwa w utworach karbonu węglonośnego – w górnośląskiej serii piaskowcowej i krakowskiej serii piaskowcowej oraz jeden w utworach miocenu – w warstwach dębowieckich. Z tych trzech jednostek, najkorzystniejszymi parametrami geologicznymi i hydrogeologicznymi dla składowania CO2 charakteryzują się warstwy dębowieckie. Największy potencjał ma obszar położony na zachód od Bielska-Białej pomiędzy Cieszynem i Czechowicami-Dziedzicami. Obliczone pojemności składowania dla warstw dębowieckich w tym rejonie szacowane są na 40–60 Mt. Utrudnieniem dla składowania CO2 jest fakt, że teren ten w znacznej części pokryty jest obszarami Natura 2000 i parkami krajobrazowymi.
This article presents a study of possible locations for CO2 storage reservoirs in the brine aquifers in the Upper Silesian Coal Basin. Based on the analysis of the geological structure and hydrogeological characteristics three brine aquifers have been designated for possible CO2 storage: two in the Carboniferous deposits – in the Upper Silesian Sandstone Series and Cracow Sandstone Series – and one in the Miocene deposits of the Dębowiec Beds. Among these three series the most adequate conditions for potential CO2 storage are present in the Dębowiec Beds. The most promising area is located to the west of Bielsko-Biała between Cieszyn and Czechowice-Dziedzice. Capacity for CO2 storage in this region is estimated at 40–60 Mt. Because a considerable part of the area is covered by the Nature 2000 protection and landscape parks, some problems may arise for the CO2 storage plans.
Źródło:
Biuletyn Państwowego Instytutu Geologicznego; 2012, 448 (1); 47--56
0867-6143
Pojawia się w:
Biuletyn Państwowego Instytutu Geologicznego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Possibilities of underground CO2 storage in the Upper Silesian region
Możliwości podziemnego składowania CO2 w regionie górnośląskim
Autorzy:
Solik-Heliasz, E.
Powiązania:
https://bibliotekanauki.pl/articles/216228.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
składowanie CO2
GZW
zatłaczanie CO2
pokład węgla
CCS
CO2 storage
Upper Silesian Coal Basin
CO2 injection
coal seams
Opis:
The results of investigations hitherto performed indicate that in the Upper Silesian region exists the possibility of carbon dioxide storage in geological structures. However, taking into account the considerable urbanisation degree, for storage are suitable water-bearing horizons and hard coal seams located on the outskirts of the agglomeration, whereas because of safety reasons areas intensively industrialised are not suitable (towns, large industrial objects). The best conditions for CO2 injection were ascertained in the horizon of Dębowiec layers in the Skoczów-Zebrzydowice area. The determined storage site has a sufficient capacity for the needs of a local CO2 emitter. The storage possibility concerns also mine workings of selected abandoned hard coal mines. The results of initial investigations have pointed out that the creation in the workings of low-pressure reservoirs (with pressure up to 0.6 MPa) or high-pressure reservoirs in selected, isolated workings (for pressure exceeding 1 MPa) can be considered. However, their storage capacity will be lower than in the water-bearing layers. Potential storage possibilities are connected also with hard coal seams - particularly seams occurring at great depth, in areas considerably tectonically affected and flooded, beyond the range of operating mines. However, it should be taken into consideration that possible CO2 injection will cause that coal resources in the CO2 storage area never could be extracted using mining methods or be subject to gasification and that other type of economic activity could be conducted only at a considerable distance, beyond the range of their mutual influence.
Wyniki dotychczasowych badań wskazują, że w regionie górnośląskim istnieje możliwość składowania dwutlenku węgla w strukturach geologicznych. Jednak ze względu na znaczny stopień zurbanizowania do składowania nadają się poziomy wodonośne i pokłady węgla kamiennego zlokalizowane na obrzeżu aglomeracji, natomiast nie kwalifikują się ze względów bezpieczeństwa obszary silnie zindustrializowane (miast, dużych obiektów przemysłowych i innych). Najlepsze warunki do zatłaczana CO2 stwierdzono w poziomie warstw dębowieckich w rejonie Skoczów-Zebrzydowice. Wyznaczone składowisko ma pojemność wystarczającą na potrzeby lokalnego emitenta CO2. Możliwość składowania dotyczy również wyrobisk górniczych wybranych zlikwidowanych kopalń węgla kamiennego. Wyniki wstępnych badań wykazały, że można rozważać utworzenie w nich zbiorników niskociśnieniowych (o ciśnieniu do 0,6 MPa) lub w wybranych, izolowanych wyrobiskach, zbiorników wysokociśnieniowych (na ciśnienie powyżej 1 MPa). Ich pojemność składowania będzie jednak mniejsza, niż w warstwach wodonośnych. Potencjalnie możliwości składowania są związane również z pokładami węgla kamiennego - zwłaszcza zalegającymi na dużej głębokości, w obszarach znacznie zaangażowanych tektonicznie i zawodnionych, poza zasięgiem czynnego górnictwa. Należy jednak mieć na uwadze, że ewentualne zatłaczanie CO2 spowoduje, iż zasoby węgla w rejonie składowiska CO2 nigdy nie będą mogły być eksploatowane metodami górniczymi lub poddane zgazowaniu, oraz że będzie można prowadzić innego typu działalność gospodarczą tylko w znacznej odległości, poza zasięgiem ich wzajemnego oddziaływania.
Źródło:
Gospodarka Surowcami Mineralnymi; 2010, 26, 3; 53-65
0860-0953
Pojawia się w:
Gospodarka Surowcami Mineralnymi
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies