Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "probe" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
Assessment of the impact of probe head hysteresis on the accuracy of five-axis coordinate measuring systems
Autorzy:
Gąska, P.
Gruza, M.
Gąska, A.
Harmatys, W.
Sładek, J.
Powiązania:
https://bibliotekanauki.pl/articles/102633.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
articulating probe head
hysteresis
accuracy
CMM
Opis:
One of the factors affecting the accuracy of Coordinate Measuring Systems is hysteresis of a probe head. It is important especially in case of touch trigger probes and should be taken into account during the determination of probing strategy. In this article, the authors try to assess how this phenomenon affects the accuracy of five axis coordinate systems which utilize articulating probe head. Such systems allow to measure point coordinates using rotary movements of the head what introduces changes to the probing process. The experiments presented in this paper are based on multiple measurements of the reference elements such as gauge blocks and standard ring.
Źródło:
Advances in Science and Technology. Research Journal; 2017, 11, 3; 277-282
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problemy związane z korekcją promienia końcówki pomiarowej podczas skaningowych pomiarów współrzędnościowych
Difficulties with the corrected measured point determination in coordinate metrology
Autorzy:
Woźniak, A.
Mayer, M.
Cote, M.
Powiązania:
https://bibliotekanauki.pl/articles/153572.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
Współrzędnościowa Maszyna Pomiarowa
WMP
sonda głowica skaningowa
korekcja promienia końcówki
Coordinate Measuring Machine
CMM
scanning probe
probe radius compensation
Opis:
W artykule przedstawiono analizy teoretyczne i badania doświadczalne potwierdzające, że korekcja promienia końcówki pomiarowej może być istotnym źródłem błędów podczas saningowych pomiarów przeprowadzanych na maszynach współrzędnościowych. Przedstawiono wyniki pomiarów przykładowego elementu na maszynie Mitutoyo LEGEX 910 CMM wyposażonej w sondę skaningową MPP-300, ze wskazaniem mechanizmów złej korekcji promienia końcówki pomiarowej.
Paper discusses an understanding for the compensation of the probe ball radius in a scanning process carried out by coordinate measuring machines (CMM). According to some initial trials of scanning measurement using the stylus tip radius correction built-in the CMM software, it was found, as will be shown in the paper, that the indigenous CMM software do not compensate the stylus tip radius well. As a result, the information about the real shape of the measured reatures can be distored. The difficulties with the corrected measured point determination will be demonstrate no the basis of tests were carried out on a Mitutoyo LEGEX 910 CMM equipped with a MPP-300 scanning probe.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9 bis, 9 bis; 485-488
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of measured workpiece’s form errors influence on the accuracy of probe heads used on five-axis measuring systems
Autorzy:
Harmatys, W.
Gąska, A.
Gruza, M.
Gąska, P.
Sładek, J.
Powiązania:
https://bibliotekanauki.pl/articles/102182.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
articulating probe head
five-axis system
accuracy
CMM
Opis:
The five-axis measuring systems are one of the most modern inventions in coordinate measuring technique. They are capable of performing measurements using only the rotary pairs present in their kinematic structure. This possibility is very useful because it may cause significant reduction of total measurement time and costs. However, it was noted that high values of measured workpiece’s form errors may cause significant reduction of the accuracy of a five-axis measuring system. The investigation on the relation between these two parameters was conducted in this paper and possible reasons of decrease in measurement accuracy was discussed on the example of measurements of workpieces with form errors ranging from 0,5 to 1,7 millimetre.
Źródło:
Advances in Science and Technology. Research Journal; 2017, 11, 4; 305-310
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Model kinetyczny przetwornika pasywnych głowic skaningowych CMM
Kinetic model of CMM scanning passive probe transducer
Autorzy:
Krajewski, G.
Woźniak, A.
Powiązania:
https://bibliotekanauki.pl/articles/155447.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
głowica skanująca
współrzędnościowa maszyna pomiarowa
CMM
scanning probe
coordinate measuring machine
Opis:
W artykule przedstawiono analizę teoretyczną budowy przetwornika głowic skaningowych pasywnych stosowanych do pomiarów w technice współrzędnościowej. W efekcie podjętych prac autorzy otrzymali wstępny model dynamiczny pracy głowic, który może posłużć do kompensacji ich błędów powstałych na skutek zwiększenia prędkości pomiarowej.
Scanning probes, also known as measuring probes, are one of the most often used equipment of coordinate measuring machines (CMM) owing to ability of collecting large number of measuring points as well as taking fast measurements. High speed of measurements and high accuracy of the measuring system are two critical parameters deciding about the machine effectiveness. Dynamics is the most significant factor limiting the measurement accuracy. In most investigations of scanning CMM there is not separated the probing system performance from other sources of the machine errors, so the true error influenced by the probing system is not profoundly determined. This paper presents the scanning probe model regardless of the machine links. The worked out model allows for better understanding of the probing process with higher speed and optimising the measuring process. The future works will aim at proposing optimisation algorithms and applying them to the probing system as well as obtaining improvement in the accuracy.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 1, 1; 50-51
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Two dimensional model of CMM probing system
Autorzy:
Ali, Salah H.R.
Powiązania:
https://bibliotekanauki.pl/articles/950738.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
CMM
trigger probe
stylus tip
tip root errors
and two-dimensional-model (2DM)
Opis:
A coordinate measuring machine (CMM) as an automation technology is playing the key role in the modern industry to improve the measurement accuracy. Accurate probing that is computer controlled is the current trend for the next generation of coordinate metrology. However, the CMM probing system is limited by its dynamic root errors that may markedly affect its response characteristics. In this paper, dynamic response errors of CMM measurements have been analyzed. The adopted probe stylus sizes throughout the course of measurements are found to cause some waviness errors during CMM operations due to each of the prescribed angle of the probe tip contact point with the specimen surface and the radius of the stylus tip. Variations in the geometry of the stylus have their consequent effects on its inherent intrinsic dynamic characteristics that in turn would cause relevant systematic root errors in the resulted measurements. Unforeseeable geometrical errors of a CMM using a ductile touch-trigger probing system have been characterized theoretically. These results are analyzed in order to investigate the effect of the dynamic root errors in the light of six probe stylus tip of the situation into account when assessing the accuracy of the CMM measurements. Analytical approaches have been applied on a developed two dimensional model (2DM) of stylus tip to demonstrate the capability of such approaches of emphasizing the root error concept using the strategy of CMM ductile trigger type of probe.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2010, 4, 2; 3-7
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Korekcja charakterystyki metrologicznej głowicy przełączającej we współrzędnościowej technice pomiarowej
The Touch-Trigger Probe Metrological Characteristics Correction in the Coordinate Measuring Technique
Autorzy:
Swornowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/157583.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
współrzędnościowa maszyna pomiarowa
WMP
głowica stykowa
korekcja charakterystyki metrologicznej
coordinate measuring machine
CMM
trigger probe
metrological characteristic correction
Opis:
W artykule przedstawiono wyniki polepszenia charakterystyki metrologicznej trójpodporowej głowicy przełączającej (impulsowej). Wyeliminowano dwie największe wady tych głowic, a mianowicie iskrzenie na stykach oraz "trójgraniastą" charakterystykę. Zbudowano od podstaw głowice (PS-3) w której zmodernizowano część mechaniczną polegającą na dodaniu do klasycznego zespołu przełączającego trzech dodatkowych mikroprzełączników oraz umieszczeniu ich pod istniejącymi stykami głównymi głowicy. Dodano również blok elektroniczny, którego zadaniem jest odpowiednie formowanie impulsów wychodzących z głowicy oraz stworzono oprogramowanie, w którym dokonuje się korekcji "surowego" wyniku.
In this article, the result of the metrological characteristic improvement has been presented. The investigation dealt with the pulse probe head with three pillars for Coordinate Measuring Machines, where two problems were to solve: scintillation on the electrical contacts and "triangular" characteristics. The new probe head (PS-3) with modernized mechanics was constructed. To the switching unit were added three more microswitches placed under the main contacts of the head. The additional electronic block was introduced, too, which had to form output pulses and perform calculations. The additional software was to correct the "rough" data.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9 bis, 9 bis; 482-484
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies