Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Combined Heat and Power (CHP)" wg kryterium: Temat


Wyświetlanie 1-8 z 8
Tytuł:
Analysis of the actual technical and operational parameters of gas cogeneration sets with combustion engines
Autorzy:
Dużyński, A.
Powiązania:
https://bibliotekanauki.pl/articles/246140.pdf
Data publikacji:
2010
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
CHP
combined heat and power (CHP)
gas cogeneration sets
combustion engines
Opis:
The present paper is the result of the author's research project no. 4 T12D 030 28 on the "Analysis of the actual technical and operational parameters of gas CHP sets" carried out by him in the years 2005-08, and financed by the Ministry of Science and Informatization in Warsaw. The primary scientific objective of the Project was to establish, compare and analyze the actual values of basic technical, operational and economic parameters for different CHP (Combined Heat and Power) sets driven by gas piston engines, operated in Poland. An analysis of the techniques of fuel gas utilization in piston engine-driven cogeneration sets, being currently used (and also likely to be used in the future), finding their application in combined energy management, has been made within the Project, and a review of the operational conditions of a dozen or so CHP sets operated in Poland, fed by biogas, mine gas from hard coal mine demethanization has been carried out. The results of this analysis have been included in the present monograph which, in addition to the review of the conditions of CHP set operation, provides conclusions that have also utility importance, and therefore can well be useful in making the optimal design of a combined energy system consisting of combustion heat- and power-generating sets.
Źródło:
Journal of KONES; 2010, 17, 1; 125-133
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reaktory zgazowania biomasy w układach CHP - przyszłość energetyki odnawialnej w Polsce
Reactor for biomass gasification in the CHP systems - future of the renewable energy in Poland
Autorzy:
Sobolewski, A.
Kotowicz, J.
Matuszek, K.
Iluk, T.
Powiązania:
https://bibliotekanauki.pl/articles/283099.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
biomasa
zgazowanie
gaz procesowy
OZE
CHP
biomass
gasification
process gas
RES
combined heat and power (CHP)
Opis:
W artykule przedstawiono podstawowe europejskie i krajowe uwarunkowania prawne dotyczące odnawialnych źródeł energii. Uwagę skupiono na wykorzystaniu OZE, w tym głównie biomasy w Polsce. Zaprezentowano definicję biomasy, krótką charakterystykę tego paliwa oraz możliwe źródła jego pozyskania. Omówiono proces zgazowania, stosowane gazogeneratory, krótką charakterystykę i specyfikę ich działania oraz kierunki wykorzystania gazu procesowego ze szczególnym uwzględnieniem układów CHP wyposażonych w reaktory zgazowania biomasy. Szczegółowo przedstawiono i omówiono wybrane konstrukcje reaktorów przeznaczonych do zgazowania biomasy opracowane w Polsce. Porównano podstawowe parametry procesu zgazowania dla prezentowanych instalacji. Przedstawiono zalety i wady gazogeneratorów pod kątem ich eksploatacji. Przeanalizowano potencjał rynkowy biomasy w kraju z przeznaczeniem na cele energetyczne. Sprecyzowano i opisano działania, których realizacja wpłynie korzystnie na rozwój energetyki odnawialnej w Polsce.
This paper presents the basic determinations of the European and national legislation concerning Renewable Energy Sources (RES). The attention was focused on the use of RES, including mainly biomass, in Poland. The definition of biomass, a short description of this fuel and the possible sources of acquisition were presented. The process of gasification and gasifiers applied were presented, and a short characteristic and specifics of their operation and directions of the use of process gas with particular emphasis on systems equipped with CHP biomass gasification reactors were described. The selected designs of reactors for biomass gasification developed in Poland were presented and discussed in details. A comparison of the basic parameters of the gasification process for the presented installations was made. Gasifiers' advantages and disadvantages at an angle of their exploitation were presented. The market potential of the biomass in Poland for energetic purposes was analyzed. The activities of which realization will influence the development of renewable energy in Poland were specified and described.
Źródło:
Polityka Energetyczna; 2011, 14, 2; 349-360
1429-6675
Pojawia się w:
Polityka Energetyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Podsumowanie trzyletniej eksploatacji biogazowego zespołu kogeneracyjnego w oczyszczalni ścieków Warta S.A. w Częstochowie
A summary of three years’ operation of the biogas cogeneration set at the Warta S.A. waste treatment plant in Czestochowa
Autorzy:
Dużyński, A.
Powiązania:
https://bibliotekanauki.pl/articles/310661.pdf
Data publikacji:
2012
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
silnik biogazowy
zespół kogeneracyjny
CHP
eksploatacja przemysłowa
biogas engine
cogeneration set
combined heat and power (CHP)
commercial operation
Opis:
W pracy omówiono dotychczasową, trzyletnią eksploatację przemysłową biogazowego zespołu kogeneracyjnego z silnikiem GE JENBACHER typu JMS 316 GS-B.LC pracującego od końca grudnia 2008 roku w Oczyszczalni Ścieków WARTA S.A. w Częstochowie. Analizowano czas pracy i postojów zespołu CHP, liczbę rozruchów i jego dyspozycyjność, produkcję energii elektrycznej i ciepła, średnie godzinowe obciążenie elektryczne i cieplne zespołu CHP, bilans energii elektrycznej i ciepła oczyszczalni oraz stopień pokrycia zapotrzebowania oczyszczalni na energię elektryczną i ciepło produkcją własną, jednostkowe zużycie biogazu przez zespół kogeneracyjny, prace serwisowe i awarie zespołu kogeneracyjnego oraz uzyskane efekty ekonomiczne z eksploatacji tego zespołu. Praca jest kontynuacją wcześniejszych publikacji [3, 6, 7, 8, 9] i łącznie z nimi stanowi unikatowe kompendium wiedzy dla przyszłych eksploatatorów biogazowych zespołów CHP w postaci zbioru rzeczywistych danych eksploatacyjnych, jednego z najbardziej reprezentatywnych pod względem mocy elektrycznej (ok. 0,8 MW), biogazowego zespołu kogeracyjnego eksploatowanego w krajowych oczyszczalniach ścieków.
The paper discusses three years’ commercial operation to date of the Biogas Cogeneration (CHP) Set driven with the JMS 316 GS-B.LC GE JENBACHER type engine, which has been operating in the WARTA S.A. Sewage Treatment Plant of Czestochowa since the end of December 2008. The analysis covered the CHP Set’s operation and shutdown times, number of start-ups and availability, electric energy and heat generation, and average hourly electric and thermal load; the Sewage Treatment Plant’s electric energy and heat balance and the degree of coverage of its electric energy and heat demand by its own production; the unit biogas consumption by the CHP Set; the service work carried out on, and failures of the CHP Set; and the economic effects gained from the operation of the Set. The study is a continuation of the previous publications [3], [6], [7], [8], [9] and, jointly with them, constitutes a unique compendium of knowledge for future operators of CHP biogas sets in the form of a collection of actual operational data for one of the most representative biogas cogeneration sets operated in domestic sewage plants in terms of electric power (approx. 0.8 MW).
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2012, 13, 10; 43-51
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Szacowanie emisji tlenków azotu (NOx) na podstawie danych eksploatacyjnych rzeczywistego obiektu przemysłowego
Estimation of nitrogen oxides NOx emission based on data from real industry plant
Autorzy:
Gramacki, A.
Gramacki, J.
Powiązania:
https://bibliotekanauki.pl/articles/154296.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
NOx
Elektrociepłownia Zielona Góra
regresja liniowa
szacowanie
NOx emission
combined heat and power plant
CHP
linear regression
Opis:
W pracy podjęto próbę szacowania emisji tlenków azotu (NOx,) na podstawie danych eksploatacyjnych zbieranych podczas normalnej pracy Elektrociepłowni w Zielonej Górze. Pomimo że zanieczyszczenia te monitorowane są z użyciem specjalistycznych czujników, to wydaje się, że dodatkowa ich kontrola może być bardzo pożądana. Zwłaszcza, że ilość emitowanych zanieczyszczeń (w tym NOx) jest ściśle limitowana i kontrolowana. Wspomniane szacowanie wykonano wykorzystując technikę statystyczną zwaną regresją liniową.
In the paper there is analysed the possibility of estimating nitrogen oxides NOx emissions based on the data taken from an industry plant (gas-based combined heat and power (CHP) plant in Zielona Góra, Poland). Even though the emission of NOx is monitored on-line by dedicated sensors installed on the plant, we believe that some additional monitoring would be desirable. This is especially important because emission of different kind of air-pollutants (including NOx) is strictly limited and monitored. The above mentioned estimation is performed by the statistical technique known as linear regression. In Section 2 the gas-based combined heat and power plant in Zielona Góra is briefly described. A simplified chart of the plant is shown in Fig. 1. The list of measurement points taken from the DCS system (distributed control system) of the greatest influence on the NOx emission is also given. In Section 3 there is shown the way how the raw data should be prepared, especially in the context of removing unwanted disturbances as well as the points which were selected for the final regression analysis. The results obtained are presented in Section 4. The best regression solution (row 3 in Table 3) is shown in Fig. 4. The accuracy is quite satisfactory and we believe that it is sufficient for the purpose of additional monitoring the main NOx sensors installed on the plant.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 7, 7; 461-463
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estymacja nieparametryczna wybranych parametrów bloku gazowo-parowego
Nonparametric estimation of selected parameters of steam and gas power plant
Autorzy:
Gramacki, J.
Gramacki, A.
Powiązania:
https://bibliotekanauki.pl/articles/154300.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
estymacja nieparametryczna
estymacja jądrowa
Elektrociepłownia Zielona Góra
nonparametric estimation
kernel estimation
combined heat and power plant
CHP
Opis:
W pracy pokazano przykład użycia nieparametrycznej estymacji danych. Z pomocą tej techniki dokonano oszacowania emisji tlenków azotu (NOx) na podstawie danych eksploatacyjnych zbieranych podczas normalnej pracy Elektrociepłowni w Zielonej Górze. Na wstępnie dokonano krótkiego przeglądu najbardziej popularnych technik estymacji parametrycznej i porównano je z technikami nieparametrycznymi. Następnie na prostym przykładzie pokazano istotę działania estymacji nieparametrycznej. Pracę kończy rozdział, w którym krótko omówiono uzyskane wyniki symulacyjne.
In the paper there are shown some practical examples of using nonparametric estimation. Using this technique there were estimated the nitrogen oxides (NOx) emissions based on the data taken from a real industry plant (gas and steam combined heat and power (CHP) plant in Zielona Góra, Poland). This work can be treated as a continuation of the paper [2]. In the first section there is given a short overview of estimation methods, including the linear and nonlinear regression, and comparison of them with nonparametric ones. In the second section there is briefly presented the nonparametric estimation technique and there is given a simple illustrative example. The third paragraph is dedicated to presenting the experimental results. Basing on the data from the CHP plant, the NOx emission was estimated and the satisfactory results (in comparison, for example, with the results obtained from the linear regression estimator) were obtained. All calculations were carried out using np package for R-project environment which implements a variety of nonparametric (and also semiparametric) kernel-based estimators.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 7, 7; 454-456
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The tests of micro-CHP prototype with SI engine powered by LPG and natural gas
Autorzy:
Przybyła, Grzegorz
Ziółkowski, Łukasz
Buczak, Mateusz
Żmudka, Zbigniew
Powiązania:
https://bibliotekanauki.pl/articles/2097651.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Naukowe Silników Spalinowych
Tematy:
SI engine
efficiency
natural gas
combined heat and power
CHP
LPG
silnik ZI
wydajność
gaz ziemny
elektrociepłownia
Opis:
This paper presents the experimental results of a Combined Heat and Power (CHP) prototype based on a SI V-twin internal combustion engine driving a synchronous generator. The paper presents the criteria that were used to select the combustion engine and the electrical generator for the prototype. The internal combustion engine has been adapted to be fuelled by natural gas or LPG, with the possibility of controlling the load in two ways, i.e. by changing the throttle position (quantitatively) and/or the value of the excess air ratio by changing the fuel dose at a constant throttle position (qualitatively). The applied method of control allows to improve the efficiency of the engine especially in the range of partial loads. The experimental tests were carried out at a constant speed of 1500 rpm. During the tests, the fuel consumption of the internal combustion engine, the composition of the exhaust gas at the outlet of the exhaust system, the electrical parameters of the synchronous generator and the temperature at selected locations of the CHP system instance were measured. According to the obtained results, there was a slight increase in the efficiency of electricity generation with the application of the developed method of control of the combustion engine. The maximum power generation efficiency for Natural Gas (NG) was higher compared to LPG by more than 2 percentage points. The exhaust gas emission level confirm that the prototype cogeneration system meets the Stage II emission standard (in accordance with Directive 2002/08/EC for small SI engines with a power below 19 kW. D2 ISO 8178).
Źródło:
Combustion Engines; 2022, 61, 2; 47--53
2300-9896
2658-1442
Pojawia się w:
Combustion Engines
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A mathematical model of two-stage Solid Oxide Fuel Cell, SOFC, stacks for dynamic simulation of Combined Heat and Power system fed by natural gas
Autorzy:
Palus, Mateusz
Pianko-Oprych, Paulina
Powiązania:
https://bibliotekanauki.pl/articles/1849268.pdf
Data publikacji:
2021
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
dynamic model
natural gas
Solid Oxide Fuel Cell stacks
Combined Heat and Power
CHP
system
Balance of Plant
BoP
modelling
Catalytic Partial Oxidation
CPOx
reformer
steam reformer
Opis:
Zero-dimensional two-stage SOFC stacks dynamic model was developed to investigate the effect of operating parameters on stacks performance. The model resolves spatially thermal and thermo-electrochemical behaviour for electrochemical reactions, Catalytic Partial Oxidation and Steam Reforming processes. Design variables and thermo-electrochemical properties were obtained from in-house-fabricated SOFCs carried out by project partners. The completed SOFCs based Combined Heat and Power, CHP, system model was validated by data18 and numerical results obtained at steady-state mode showing its high-fidelity. A parametric study with respect to key operating parameters including changes in fuel utilization, lambda number and current density values was conducted. The global CHP system dynamic response, in term of the current/voltage delivered by two-stage SOFC stacks, under a fi xed fuel utilization, has been determined resulting in greater variations in the voltage of a single cell in the first stack in comparison to the corresponding values in the second stack.
Źródło:
Polish Journal of Chemical Technology; 2021, 23, 2; 1-11
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A mathematical model of two-stage Solid Oxide Fuel Cell, SOFC, stacks for dynamic simulation of Combined Heat and Power system fed by natural gas
Autorzy:
Palus, Mateusz
Pianko-Oprych, Paulina
Powiązania:
https://bibliotekanauki.pl/articles/1849273.pdf
Data publikacji:
2021
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
dynamic model
natural gas
Solid Oxide Fuel Cell stacks
Combined Heat and Power
CHP
system
Balance of Plant
BoP
modelling
Catalytic Partial Oxidation
CPOx
reformer
steam reformer
Opis:
Zero-dimensional two-stage SOFC stacks dynamic model was developed to investigate the effect of operating parameters on stacks performance. The model resolves spatially thermal and thermo-electrochemical behaviour for electrochemical reactions, Catalytic Partial Oxidation and Steam Reforming processes. Design variables and thermo-electrochemical properties were obtained from in-house-fabricated SOFCs carried out by project partners. The completed SOFCs based Combined Heat and Power, CHP, system model was validated by data18 and numerical results obtained at steady-state mode showing its high-fidelity. A parametric study with respect to key operating parameters including changes in fuel utilization, lambda number and current density values was conducted. The global CHP system dynamic response, in term of the current/voltage delivered by two-stage SOFC stacks, under a fi xed fuel utilization, has been determined resulting in greater variations in the voltage of a single cell in the first stack in comparison to the corresponding values in the second stack.
Źródło:
Polish Journal of Chemical Technology; 2021, 23, 2; 1-11
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies