Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "L. N." wg kryterium: Autor


Wyświetlanie 1-8 z 8
Tytuł:
Time-of-Flight Positron Emission Tomography with Resistive Plate Chamber Detectors: An Unlikely but Promising Approach
Autorzy:
Couceiro, M.
Crespo, P.
Blanco, A.
Ferreira, N.
Mendes, L.
Ferreira Marques, R.
Fonte, P.
Powiązania:
https://bibliotekanauki.pl/articles/1402607.pdf
Data publikacji:
2015-05
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
87.57.uk
29.40.Cs
87.57.cf
87.57.cm
Opis:
The cost-effectiveness of resistive plate chamber detectors and their very good timing characteristics, open the possibility to build affordable time-of-flight positron emission tomography systems with a large axial field-of-view. Simulations suggest that, under reasonable assumptions, the absolute 3D true sensitivity, spatial resolution, and noise equivalent count rate of such systems for human whole-body screening, may exceed that of present crystal-based PET technology. However, due to the lack of energy resolution, although having energy sensitivity, the scatter fraction is expected to be considerably higher than that presented by crystal-based PET scanners. In the present paper, the simulation work done so far to access the expected performance of a resistive plate chamber time-of-flight-PET system with 2400 mm length axial field-of-view, a time resolution of 300 ps full width at half maximum for photons pairs, and depth-of-interaction information, will be revised.
Źródło:
Acta Physica Polonica A; 2015, 127, 5; 1453-1461
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
GPU Accelerated Image Reconstruction in a Two-Strip J-PET Tomograph
Autorzy:
Białas, P.
Kowal, J.
Strzelecki, A.
Bednarski, T.
Czerwiński, E.
Gajos, A.
Kamińska, D.
Kapłon, Ł.
Kochanowski, A.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krzemień, W.
Kubicz, E.
Moskal, P.
Niedźwiecki, Sz.
Pałka, M.
Raczyński, L.
Rudy, Z.
Rundel, O.
Salabura, P.
Sharma, N.
Silarski, M.
Słomski, A.
Smyrski, J.
Wieczorek, A.
Wiślicki, W.
Zieliński, M.
Zoń, N.
Powiązania:
https://bibliotekanauki.pl/articles/1402623.pdf
Data publikacji:
2015-05
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
87.57.nf
87.57.uk
Opis:
We present a fast GPU implementation of the image reconstruction routine, for a novel two strip PET detector that relies solely on the time of flight measurements.
Źródło:
Acta Physica Polonica A; 2015, 127, 5; 1500-1504
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hit Time and Hit Position Reconstruction in the J-PET Detector Based on a Library of Averaged Model Signals
Autorzy:
Moskal, P.
Sharma, N.
Silarski, M.
Bednarski, T.
Białas, P.
Bułka, J.
Czerwiński, E.
Gajos, A.
Kamińska, D.
Kapłon, L.
Kochanowski, A.
Korcyl, G.
Kowal, J.
Kowalski, P.
Kozik, T.
Krzemień, W.
Kubicz, E.
Niedźwiecki, Sz.
Pałka, M.
Raczyński, L.
Rudy, Z.
Rundel, O.
Salabura, P.
Słomski, A.
Smyrski, J.
Strzelecki, A.
Wieczorek, A.
Wiślicki, W.
Wochlik, I.
Zieliński, M.
Zoń, N.
Powiązania:
https://bibliotekanauki.pl/articles/1402622.pdf
Data publikacji:
2015-05
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
87.57.uk
07.05.Kf
Opis:
In this article we present a novel method of hit time and hit position reconstruction in long scintillator detectors. We take advantage of the fact that for this kind of detectors amplitude and shape of registered signals depend strongly on the position where particle hits the detector. The reconstruction is based on determination of the degree of similarity between measured and averaged signals stored in a library for a set of well-defined positions along the scintillator. Preliminary results of validation of the introduced method with experimental data obtained by means of the double strip prototype of the J-PET detector are presented.
Źródło:
Acta Physica Polonica A; 2015, 127, 5; 1495-1499
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multiple Scattering and Accidental Coincidences in the J-PET Detector Simulated Using GATE Package
Autorzy:
Kowalski, P.
Moskal, P.
Wiślicki, W.
Raczyński, L.
Bednarski, T.
Białas, P.
Bułka, J.
Czerwiński, E.
Gajos, A.
Gruntowski, A.
Kamińska, D.
Kapłon, Ł.
Kochanowski, A.
Korcyl, G.
Kowal, J.
Kozik, T.
Krzemień, W.
Kubicz, E.
Niedźwiecki, Sz.
Pałka, M.
Rudy, Z.
Salabura, P.
Sharma, N.
Silarski, M.
Słomski, A.
Smyrski, J.
Strzelecki, A.
Wieczorek, A.
Wochlik, I.
Zieliński, M.
Zoń, N.
Powiązania:
https://bibliotekanauki.pl/articles/1402625.pdf
Data publikacji:
2015-05
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
29.40.Mc
87.57.uk
87.10.Rt
34.50.-s
Opis:
Novel positron emission tomography system, based on plastic scintillators, is developed by the J-PET collaboration. In order to optimize geometrical configuration of built device, advanced computer simulations are performed. Detailed study is presented of background given by accidental coincidences and multiple scattering of gamma quanta.
Źródło:
Acta Physica Polonica A; 2015, 127, 5; 1505-1512
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis Framework for the J-PET Scanner
Autorzy:
Krzemień, W.
Gajos, A.
Gruntowski, A.
Stola, K.
Trybek, D.
Bednarski, T.
Białas, P.
Czerwiński, E.
Kamińska, D.
Kapłon, Ł.
Kochanowski, A.
Korcyl, G.
Kowal, J.
Kowalski, P.
Kozik, T.
Kubicz, E.
Moskal, P.
Niedźwiecki, Sz.
Pałka, M.
Raczyński, L.
Rudy, Z.
Salabura, P.
Sharma, N.
Silarski, M.
Słomski, A.
Smyrski, J.
Strzelecki, A.
Wieczorek, A.
Wiślicki, W.
Zieliński, M.
Zoń, N.
Powiązania:
https://bibliotekanauki.pl/articles/1402621.pdf
Data publikacji:
2015-05
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
87.57.nf
87.57.uk
29.85.-c
Opis:
J-PET analysis framework is a flexible, lightweight, ROOT-based software package which provides the tools to develop reconstruction and calibration procedures for PET tomography. In this article we present the implementation of the full data-processing chain in the J-PET framework which is used for the data analysis of the J-PET tomography scanner. The framework incorporates automated handling of PET setup parameters' database as well as high level tools for building data reconstruction procedures. Each of these components is briefly discussed.
Źródło:
Acta Physica Polonica A; 2015, 127, 5; 1491-1494
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Pilot Study of the Novel J-PET Plastic Scintillator with 2-(4-styrylphenyl)benzoxazole as a Wavelength Shifter
Autorzy:
Wieczorek, A.
Moskal, P.
Niedźwiecki, S.
Bednarski, T.
Białas, P.
Czerwiński, E.
Danel, A.
Gajos, A.
Gruntowski, A.
Kamińska, D.
Kapłon, Ł.
Kochanowski, A.
Korcyl, G.
Kowal, J.
Kowalski, P.
Kozik, T.
Krzemień, W.
Kubicz, E.
Molenda, M.
Pałka, M.
Raczyński, L.
Rudy, Z.
Rundel, O.
Salabura, P.
Sharma, N.
Silarski, M.
Słomski, A.
Smyrski, J.
Strzelecki, A.
Uchacz, T.
Wiślicki, W.
Zieliński, M.
Zoń, N.
Powiązania:
https://bibliotekanauki.pl/articles/1402620.pdf
Data publikacji:
2015-05
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
87.57.uk
29.40.Mc
Opis:
For the first time a molecule of 2-(4-styrylphenyl)benzoxazole containing benzoxazole and stilbene groups is applied as a scintillator dopant acting as a wavelength shifter. In this article a light yield of the plastic scintillator, prepared from styrene doped with 2 wt% of 2,5-diphenylbenzoxazole and 0.03 wt% of 2-(4-styrylphenyl)benzoxazole, is determined to be as large as 60% ± 2% of the anthracene light output. There is a potential to improve this value in the future by the optimization of the additives concentrations.
Źródło:
Acta Physica Polonica A; 2015, 127, 5; 1487-1490
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Method to Produce Linearly Polarized Positrons and Positronium Atoms with the J-PET Detector
Autorzy:
Mohammed, Muhsin
Białas, P.
Curceanu, C.
Czerwiński, E.
Dulski, K.
Gajos, A.
Głowacz, B.
Gorgol, M.
Hiesmayr, B.
Jasińska, B.
Kisielewska, D.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krawczyk, N.
Krzemień, W.
Kubicz, E.
Pawlik-Niedźwiecka, M.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Raj, J.
Rudy, Z.
Sharma, N.
Sharma, S.
Shivani, ---
Skurzok, M.
Silarski, M.
Wieczorek, A.
Wiślicki, W.
Zgardzińska, B.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/1030045.pdf
Data publikacji:
2017-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
41.75.Fr
41.75.Ht
77.22.Ej
36.10.Dr
85.75.Mm
87.57.uk
Opis:
A method for creating linearly polarized positrons and ortho-positronium (o-Ps) atoms with the J-PET detector is presented. The unique geometry and properties of the J-PET tomography enable one to design a positron source such that the quantization axis for the estimation of the linear polarization of produced o-Ps can be determined on the event by event basis in a direction of the positron motion. We intend to use ²²Na or other β⁺ decay isotopes as a source of polarized positrons. Due to the parity violation in the beta decay, the emitted positrons are longitudinally polarized. The choice of the quantization axis is based on the known position of the positron emitter and the reconstructed position of the positronium annihilation. We show that the J-PET tomography is equipped with all needed components.
Źródło:
Acta Physica Polonica A; 2017, 132, 5; 1486-1489
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary studies of J-PET detector spatial resolution
Autorzy:
Pawlik-Niedźwiecka, M.
Niedźwiecki, S.
Alfs, D.
Białas, P.
Curceanu, C.
Czerwiński, E.
Dulski, K.
Gajos, A.
Głowacz, B.
Gorgol, M.
Hiesmayr, B.
Jasińska, B.
Kisielewska, D.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krawczyk, N.
Krzemień, W.
Kubicz, E.
Mohammed, M.
Pałka, M.
Raczyński, L.
Raj, J.
Rudy, Z.
Shivani, -
Silarski, M.
Skurzok, M.
Sharma, N.
Sharma, S.
Shopa, R.
Strzelecki, A.
Wieczorek, A.
Wiślicki, W.
Zgardzińska, B.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/1057928.pdf
Data publikacji:
2017-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
29.40.Mc
87.57.uk
87.10.Rt
34.50.-s
Opis:
The J-PET detector, based on long plastic scintillator strips, was recently constructed at the Jagiellonian University. It consists of 192 modules axially arranged into three layers, read out from both sides by digital constant-threshold front-end electronics. This work presents preliminary results of measurements of the spatial resolution of the J-PET tomograph performed with ²²Na source placed at selected position inside the detector chamber.
Źródło:
Acta Physica Polonica A; 2017, 132, 5; 1645-1648
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies