Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Zhou, S." wg kryterium: Autor


Wyświetlanie 1-2 z 2
Tytuł:
The Design and the First Test Results of a Fast LTD Stage
Autorzy:
Chen, L.
Zhou, L.
Zou, W.
Ren, J.
Li, Y.
Wu, S.
Xie, W.
Feng, S.
Deng, J.
Powiązania:
https://bibliotekanauki.pl/articles/1807988.pdf
Data publikacji:
2009-06
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
84.70.+p
52.75.Kq
84.60.Ve
Opis:
Linear transformer driver stages are designed to be used as a primary energy storage in high power pulsed generators. In this report, the design and test results of the linear transformer driver stage prototype that delivers ≈100 kA fast pulse with 133 ns FWHM into a ≈0.87 Ω resistive load are described. This stage consists of 20 (100 kV, 20 nF) storage capacitors that are arranged in 10 identical bricks located evenly around the axis of the stage. Each brick contains two capacitors, a multi-gap switch, and the output connector that transfers the energy to the resistive load. The outer diameter of the stage is ≈1.5 m, at a length of ≈20 cm. The stage is developed to demonstrate the possibility of the fast linear transformer driver technology to create high power pulsed generators.
Źródło:
Acta Physica Polonica A; 2009, 115, 6; 1186-1188
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental Studies on Charging Operation of a Compact Repetitive Tesla Transformer
Autorzy:
Zhang, Z.
Zhang, J.
Yang, H.
Qian, B.
Meng, Z.
Li, D.
Wang, S.
Cao, Y.
Zhou, W.
Powiązania:
https://bibliotekanauki.pl/articles/1807860.pdf
Data publikacji:
2009-06
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
84.30.Ng
84.30.Jc
84.30.Qi
84.70.+p
Opis:
Charging operations of a compact Tesla transformer were experimentally investigated, in single-shot and rep-rate (50 pps for 1 s) modes, respectively. The charging limitations were also explored. The experimental results were compared and analyzed. The maximum secondary charging voltages of the Tesla transformer were measured to be 380 kV and 300 kV in single-shot and rep-rate modes, respectively. The RMS pulse-to-pulse instability of the secondary charging voltage is generally less than 10% but increases with the increasing initial voltage across the primary capacitor. Since the secondary capacitor of the Tesla transformer is a pulse forming line (PFL), continued operation is possible if there is breakdown in the PFL. Furthermore, operation can even be continued under occasional breakdown for some pulses, without the effects on the operations of subsequent pulses.
Źródło:
Acta Physica Polonica A; 2009, 115, 6; 973-975
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies