Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Gawlikowski, M." wg kryterium: Autor


Wyświetlanie 1-2 z 2
Tytuł:
Physical Model of the Pulmonary Circulation Designed for Investigation on Cardiac Output Measurement by Means of the Thermodilution Method
Autorzy:
Gawlikowski, M.
Pustelny, T.
Powiązania:
https://bibliotekanauki.pl/articles/1493354.pdf
Data publikacji:
2011-10
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
87.19.Hh
47.63.Ec
82.60.Fa
Opis:
The "gold clinical standard" of cardiac output measurements is the thermodilution method, implemented by the Swan-Ganz catheter. The unreliability of obtained results is difficult to estimate experimentally, due to the lack of reference methods or the risk of serious interferences in the measured object. Moreover, the pulsating blood flow produced by the heart is difficult to measure. Therefore it is advisable to develop the physical model of the pulmonary circulation, designed to investigate the accuracy of cardiac output measurements by means of the thermodilution method.
Źródło:
Acta Physica Polonica A; 2011, 120, 4; 798-802
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Enhanced External Counterpulsation in Patients with Advanced Ischemic Cardiomyopathy
Autorzy:
Przywara-Chowaniec, B.
Gawlikowski, M.
Kuczaj, A.
Bachorz, M.
Czechowski, P.
Kowalski, P.
Geodecki, M.
Kawecki, D.
Barańska, K.
Paluch, M.
Pluszczyk, M.
Opara, M.
Puzio, A.
Nowalany-Kozielska, E.
Powiązania:
https://bibliotekanauki.pl/articles/1418031.pdf
Data publikacji:
2012-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
47.63.Ec
82.60.Fa
Opis:
A significant increase in the number of patients with heart failure of varied etiology has been observed in the recent years. Apart from pharmacological and surgical therapies, new, non-invasive assistance methods of cardiovascular system are still sought. One of them is external counterpulsation. Within this study, effectiveness of such a form of therapy has been examined in a group of 10 patients with an ischemic left ventricular systolic dysfunction. It has been shown that external counterpulsation has a beneficial influence onto the result of a six-minute walk test and causes a slight decrease in the creatinine concentration in the patients undergoing the tests.
Źródło:
Acta Physica Polonica A; 2012, 122, 5; 866-869
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies