Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "RS" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Effect of the Applied Current Density on the Structural and Magnetic Properties of the Electrodeposited Cobalt-Nickel Alloy Thin Films
Autorzy:
Özdemır, R.
Powiązania:
https://bibliotekanauki.pl/articles/1031697.pdf
Data publikacji:
2017-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
81.05.Bx
81.40.Rs
82.45.Qr
81.15.Pq
Opis:
In this study, cobalt-nickel (Co-Ni) alloys were deposited electrochemically onto aluminum substrates under applied current densities of 103.8, 138.4, 173 and 207.6 A m¯². Influence of the applied current density on the structural and magnetic properties of the Co-Ni alloys was investigated. The bath for Co-Ni alloys deposition was composed of 0.08 mol l¯¹ CoSO₄·7H₂O, 0.2 mol l¯¹ NiCl₂·6H₂O, 0.1 mol l¯¹ NiSO₄·6H₂O and 0.25 mol l¯¹ H₃BO₃. The electrochemical investigation of Co-Ni alloys was completed using cyclic voltammetry and galvanostatic studies. Inductively coupled plasma analysis has shown that the amount of the cobalt in the deposited alloy has decreased from 73.61% to 67.01% with the increase of the applied current density from 103.8 to 207.6 A m¯². According to the magnetic analysis results, the values of coercivity coefficient of the deposited Co-Ni alloys range between 115 and 150 Oe, confirming ferromagnetic behavior of the alloys. Experiment results indicate that magnetic and structural properties of the Co-Ni alloy deposits are greatly influenced by the applied current density in the electrodeposition system.
Źródło:
Acta Physica Polonica A; 2017, 132, 3; 770-774
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of the Structural and Magnetic Properties of the Cobalt-Nickel Alloys Fabricated in Various Electrolyte Solutions
Autorzy:
Özdemir, R.
Korkmaz, C.
Karahan, İ.
Powiązania:
https://bibliotekanauki.pl/articles/1031413.pdf
Data publikacji:
2017-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
81.05.Bx
81.40.Rs
81.15.Pq
82.45.Qr
Opis:
Cobalt-Nickel alloys have been widely used for decoration, in magnetic recording devices and corrosion resistance applications, etc. In this study, the influences of cobalt amount in electrolyte on the magnetic and structural properties of the electrodeposited Co-Ni alloys were investigated. An electrolyte solution, consisting of cobalt sulfate, nickel sulfate, nickel chloride and boric acid, was used in electrodeposition. The electrochemical investigation of Co-Ni alloys was completed using cyclic voltammetry and galvanostatic studies. The morphological and structural analyses of the alloys were performed using inductively coupled plasma, scanning electron microscopy, X-ray diffraction and vibrating sample magnetometer techniques. The effect of cobalt concentration on the magnetic properties, phase structure and grain size of the alloys was investigated. Magnetic hysteresis results indicate that the amount of the cobalt content in the electrolyte has a strong influence on the ferromagnetic behavior of fabricated alloys. Results of the study show that changing the electrodeposition parameters, such as composition of electrolyte solution, allows to fabricate alloys with different properties.
Źródło:
Acta Physica Polonica A; 2017, 132, 3; 1045-1049
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Corrosion resistance of tin coatings deposited by different methods
Autorzy:
Winnicki, M.
Rutkowska-Gorczyca, M.
Baszczuk, A.
Małachowska, A.
Piwowarczyk, T.
Ambroziak, A.
Powiązania:
https://bibliotekanauki.pl/articles/1154007.pdf
Data publikacji:
2016-10
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
61.05.cp
68.35.bd
81.15.Pq
81.15.Rs
81.65.Kn
Opis:
This article describes the study of corrosion resistance of tin coatings deposited onto aluminum alloy substrates using the low pressure cold spraying and electroplating methods. The chemical corrosion resistance was examined using the Kesternich and cyclic salt spray tests inside SO₂ and NaCl climate chambers, respectively. The selected tests allowed simulation of the conditions of the coatings during service. The results were satisfactory for low pressure cold spraying coatings. Coatings produced by electroplating exhibit substantial corrosive losses due to their method of application and low thickness. Evaluation of corrosion were carried out by analyzing changes in the microstructure. Additionally, the physicochemical tests were carried out using X-ray diffraction to verify corrosion changes on the coatings surface.
Źródło:
Acta Physica Polonica A; 2016, 130, 4; 1155-1157
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Titanium Surface Modification with Carbon Nanotubes. Towards Improved Biocompatibility
Autorzy:
Benko, A.
Wiecheć, A.
Rajchel, B.
Długoń, E.
Błażewicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/1398806.pdf
Data publikacji:
2016-02
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
68.37.Hk
78.30.Na
81.15.Pq
82.45.Mp
87.85.J-
87.85.Rs
Opis:
Subject of this study is surface modification of titanium with thin layers of carbon nanotubes, obtained via an electrophoretic deposition, as a means to improve metal's biocompatibility and provide a suitable matrix for very facile further modifications, if needed. Article presents a preliminary evaluation of the material, using goniometer, scanning electron microscopy and the Raman spectroscopy. The layer is found to be composed of randomly distributed, strongly adhered carbon nanotubes, introducing nanotopography to the surface of titanium. Biological studies were conducted with the human osteoblast-like cell line MG63. Biocompatibility of materials was evaluated using: (a) lactate dehydrogenase cytotoxicity test (LDH) and (b) γ -H2AX genotoxicity test (presence of DNA double strand breaks). Results confirmed non-toxic character of the tested materials. Moreover, carbon nanotubes layers enhanced the biocompatibility properties of titanium substrate - material with carbon nanotubes possessed lower cellular toxic properties even than pure titanium. The result of this preliminary study are very promising and may serve as a starting point for further studies, including further chemical or biological modification of the obtained materials.
Źródło:
Acta Physica Polonica A; 2016, 129, 2; 176-178
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies