Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Kollar, M." wg kryterium: Autor


Wyświetlanie 1-4 z 4
Tytuł:
DC Magnetic Properties of Amorphous Vitrovac Ribbon
Autorzy:
Kollár, P.
Birčáková, Z.
Füzer, J.
Kuźmiński, M.
Powiązania:
https://bibliotekanauki.pl/articles/1031042.pdf
Data publikacji:
2017-04
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
75.60.Jk
75.60.Ch
75.60.Ej
Opis:
Soft magnetic amorphous Co-based materials prepared by rapid quenching method in the form of thin ribbon are well-known due to their excellent soft magnetic properties as high permeability, low coercivity, and low magnetic losses in kHz range. The amorphous Co-Fe-B-Si material Vitrovac® 6155 U55 produced by Vacuumschmelze GmbH & Co. KG belongs to this class of materials and was investigated in as-delivered state. The aim of this work was to study DC magnetization process by various experimental methods. We have measured magnetization curve by fluxmeter based hysteresis graph and hysteresis loops by three different fluxmeter based hysteresis graphs, exhibiting significant differences. The first and the second hysteresis graph perform the hysteresis loops measurement by the point-by-point method, either with commutative or with summing steps. The third one is AC hysteresis graph working at very low frequencies down to 7 mHz, performing the continuous method. The explanation of this result is based on the structural after effect influencing the domain wall displacement. We assumed that the domain structure consists of very small number of domain walls responsible for magnetization process, which was confirmed by the visualization of static domain structure by a computer-controlled setup based on the Kerr effect.
Źródło:
Acta Physica Polonica A; 2017, 131, 4; 675-677
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of Vitroperm Content on the Energy Losses in Composite Materials Based on the Mixture of Two Ferromagnets
Autorzy:
Birčáková, Z.
Kollár, P.
Vojtek, V.
Bureš, R.
Fáberová, M.
Powiązania:
https://bibliotekanauki.pl/articles/1200792.pdf
Data publikacji:
2014-07
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
75.50.Bb
75.60.Jk
75.60.-d
Opis:
Soft magnetic composites offer several advantages such as 3D isotropic magnetic properties and relatively small energy losses, finding use in electrical devices like electromotors, transformers or sensors. The aim of this work was to investigate the dc and ac magnetic properties of composites based on the mixture of two different ferromagnets: iron based material Somaloy® 700 and Vitroperm® 500 alloy. The analysis of total losses into dc losses, classical losses and excess losses showed that the classical and excess losses were negligibly small. The specific resistivity was increasing with the increasing fraction of Vitroperm (VPM). The coercivity exhibited maximum at 20% of VPM.
Źródło:
Acta Physica Polonica A; 2014, 126, 1; 114-115
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of Magnetization Processes from the Energy Losses in Soft Magnetic Composite Materials
Autorzy:
Birčáková, Z.
Kollár, P.
Weidenfeller, B.
Füzer, J.
Fáberová, M.
Bureš, R.
Powiązania:
https://bibliotekanauki.pl/articles/1032811.pdf
Data publikacji:
2017-04
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
75.50.Bb
75.60.Jk
75.60.-d
Opis:
Soft magnetic composite materials are composed of small ferromagnetic particles insulated from each other. It gives them some very good properties e.g. the magnetic isotropy and low total energy losses at medium to higher frequencies. On the other hand, their structure gives rise to the negative aspects as the inner demagnetizing fields, resulting in some specifics in magnetization processes leading to the worsening of soft magnetic properties, particularly the excess losses increase and a lowering of permeability. The frequency dependence of excess losses, the low and high induction loss components and the inner demagnetization factors of soft magnetic composites were investigated in order to reveal the proportions of the reversible and irreversible magnetization processes. Higher excess losses were observed in samples with smaller particles or higher non-ferromagnetic content (resin+pores), in which the inner demagnetizing fields were higher. It was explained by lower effective number of movable domain walls in those samples, thus less irreversible magnetization processes. This was confirmed by low and high induction loss analysis, where total losses were divided into low and high induction loss components and plotted vs. frequency.
Źródło:
Acta Physica Polonica A; 2017, 131, 4; 684-686
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
DC Magnetic Properties and Complex Permeability of Ni-Fe Based Composites
Autorzy:
Onderko, F.
Jakubčin, M.
Dobák, S.
Olekšáková, D.
Birčáková, Z.
Kollár, P.
Füzer, J.
Fáberová, M.
Bureš, R.
Kurek, P.
Powiązania:
https://bibliotekanauki.pl/articles/1032820.pdf
Data publikacji:
2017-04
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
75.50.Bb
75.60.Jk
75.60.-d
Opis:
We have investigated soft magnetic composite materials to better understand the influence of binder (resin) content on the DC magnetic properties and the complex permeability. Soft magnetic composite samples were composed from NiFe powder with phenol formaldehyde resin (ATM). Ferromagnetic magnetic powder for ring-shaped samples was obtained by milling of small pieces cut of NiFe sheets. The obtained powder was annealed to partially remove structural defects. The prepared powder was mixed with phenol-formaldehyde resin in different vol.%. The mixtures were pressed into the ring-shape samples. Complex permeability and DC magnetic properties (initial magnetization curves, anhysteretic curves and hysteresis loops) were measured. Higher inner demagnetizing fields in the resin containing samples were responsible for higher coercivity and hysteresis losses, but the permeability was stable up to much higher frequencies, compared to the sample without the resin.
Źródło:
Acta Physica Polonica A; 2017, 131, 4; 792-794
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies