Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "DF" wg kryterium: Temat


Wyświetlanie 1-9 z 9
Tytuł:
Preliminary Research of an Optical Sensor for Measurements of the Blood Chamber Volume in the POLVAD Prosthesis
Autorzy:
Konieczny, G.
Pustelny, T.
Powiązania:
https://bibliotekanauki.pl/articles/1418094.pdf
Data publikacji:
2012-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
42.79.-e
42.81.-i
07.07.Df
47.63.Cb
Opis:
The article presents preliminary research of an optical system for using in the temporary blood volume measurements in the Polish Ventricular Assist Device (POLVAD). The basis for the proposed solution is the measurement of the light reflected from the membrane in different configurations of light emitters and light detectors. The paper is describing a proposed measurement technique, measurement circuit and preliminary static measurements results of the developed measurement system. Future development plans are stated.
Źródło:
Acta Physica Polonica A; 2012, 122, 5; 962-965
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optical Sensor for Measurements of the Blood Chamber Volume in the POLVAD Prosthesis - Static Measurements
Autorzy:
Konieczny, G.
Pustelny, T.
Marczyński, P.
Powiązania:
https://bibliotekanauki.pl/articles/1399376.pdf
Data publikacji:
2013-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
42.79.-e
42.81.-i
07.07.Df
47.63.Cb
Opis:
The paper presents results of extended static measurements of a newly developed optical system for temporary blood chamber volume measurements in the Polish Ventricular Assist Device. The paper additionally introduces a modified measurement stand and improvements of the measurements. Exemplary results acquired with principal components analysis are shown and future development plans of an optical measurement system are stated.
Źródło:
Acta Physica Polonica A; 2013, 124, 3; 479-482
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Enhancement of Refractive Index Sensitivity in Photonic Crystal Waveguide-Based Sensors by Selective Infiltration
Autorzy:
Bagci, F.
Akaoglu, B.
Powiązania:
https://bibliotekanauki.pl/articles/1399501.pdf
Data publikacji:
2013-07
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
42.70.Qs
78.67.Pt
07.07.Df
42.79.-e
Opis:
We present a liquid refractive index sensor based on a photonic crystal waveguide slab structure. Sensing mechanism employed in this study is based on the shift in cut-off wavelength as the lattice holes are selectively infiltrated. Three-dimensional plane-wave expansion and finite-difference time-domain methods are used to determine the band structure and transmission spectra, respectively. First, the sensitivity of the device is analyzed for the structure where only the first rows of holes adjacent to the line-defect are infiltrated. In addition, this analysis is repeated for a range of hole diameters. Second, the effects of infiltrated holes which are placed in the line-defect are investigated. As these infiltrated central holes are introduced, the proposed device exhibits 5.3 times improved sensitivity.
Źródło:
Acta Physica Polonica A; 2013, 124, 1; 50-55
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Results of Experiments with Fiber Pressure Sensor Applied in the Polish Artificial Heart Prosthesis
Autorzy:
Konieczny, G.
Opilski, Z.
Pustelny, T.
Gacek, A.
Gibinski, P.
Kustosz, R.
Powiązania:
https://bibliotekanauki.pl/articles/1506799.pdf
Data publikacji:
2010-12
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
42.79.-e
42.81.-i
07.07.Df
47.63.Cb
Opis:
The following paper introduces the problem of noninvasive pressure measurements in Polish artificial heart prosthesis. The pressure sensor is proposed and introduced, and preliminary tests are shown. The paper deals with the proposed sensing elements, requirement noninvasive solution and preliminary tests of polyurethane membrane transmission. The paper includes also experimental results of a fiber pressure sensor introducing noninvasive pressure measurements with pressure transmission through a polyurethane tube wall.
Źródło:
Acta Physica Polonica A; 2010, 118, 6; 1183-1185
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design of Pressure Sensor Based on Two-Dimensional Photonic Crystal
Autorzy:
Zouache, T.
Hocini, A.
Harhouz, A.
Mokhtari, R.
Powiązania:
https://bibliotekanauki.pl/articles/1033334.pdf
Data publikacji:
2017-01
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
42.70.Qs
78.67.Pt
07.07.Df
42.79.-e
Opis:
In this work, we design a new pressure sensor based on two-dimensional photonic crystal waveguide coupled to a point-defect resonant microcavity. The mechanism of sensing is based on the change of the germanium refractive index as function of the hydrostatic pressure P. The resonant wavelength will shift when pressure variation induces change in the refractive indexes of the structure. The pressure variation causes the shifting of defect modes. The properties of the refractive index sensor are simulated using the finite-difference time-domain algorithm and the plane wave expansion method. These kinds of sensors have many advantages in compactness, high sensitivity, and various choices of materials.
Źródło:
Acta Physica Polonica A; 2017, 131, 1; 68-70
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Quasi-Dynamic Testing of an Optical Sensor for Measurements of the Blood Chamber Volume in the POLVAD Prosthesis
Autorzy:
Konieczny, G.
Pustelny, T.
Marczyński, P.
Powiązania:
https://bibliotekanauki.pl/articles/1399377.pdf
Data publikacji:
2013-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
42.79.-e
42.81.-i
07.07.Df
47.63.Cb
Opis:
The article presents further developments of an optical system to be used in temporary blood volume measurements in the Polish ventricular assist device. The research focuses on quasi-dynamic measurements (flow rate of 5 ml/s). Characteristics of signals from selected configurations of optical transmitters and receivers are shown. A volume approximation using a PCA algorithm supported by a LRS function is introduced. Plans of further development are stated.
Źródło:
Acta Physica Polonica A; 2013, 124, 3; 483-485
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary Research Concerning Measurements οf the POLVAD Blood Chamber Volume Based οn Helmholtzs Acoustic Resonator Principle
Autorzy:
Konieczny, G.
Opilski, Z.
Pustelny, T.
Powiązania:
https://bibliotekanauki.pl/articles/1493249.pdf
Data publikacji:
2011-10
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
42.79.-e
42.81.-i
07.07.Df
47.63.Cb
Opis:
The article presents researches concerning a system for a possible blood volume measurements applied in POLVAD prosthesis. The proposed solution is based on the Helmholtz resonance principle. The article shows the state of art in blood volume sensors for using in the POLVAD prosthesis and introduces a newly proposed solution. The construction of the sensor and the results of static tests are presented. The work is summarized with future development plans.
Źródło:
Acta Physica Polonica A; 2011, 120, 4; 688-692
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
State of the Work Diagram of the Artificial Heart
Autorzy:
Konieczny, G.
Opilski, Z.
Pustelny, T.
Maciak, E.
Powiązania:
https://bibliotekanauki.pl/articles/1807734.pdf
Data publikacji:
2009-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
42.79.-e
42.81.-i
07.07.Df
47.63.Cb
Opis:
This paper presents the results of investigations on novel pressure measurement methods to be for used in the project "Polish Artificial Heart". The investigations concerned possible pressure sensors for noninvasive blood pressure measurements in selected points around the pneumatic ventricular assist device (POLVAD). The fiber pressure sensor and the possibility of pressure measurements with piezofoils were tested. The paper includes preliminary results and development plans.
Źródło:
Acta Physica Polonica A; 2009, 116, 3; 344-347
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of Colour-Contrast Sensitivity of the Retina
Autorzy:
Kubarko, A.
Firago, V.
Hotra, O.
Powiązania:
https://bibliotekanauki.pl/articles/1199150.pdf
Data publikacji:
2014-06
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
85.60.-q
42.79.-e
42.15.Eq
07.07.Df
42.79.Pw
Opis:
The computer methods for determining the map of colour-contrast sensitivity of the retina, suitable for mass screening of the earlier disturbances of visual and circulatory systems of humans, are discussed. The expressions for calculation, and the results of the determination of the threshold values of the photon fluxes at which young people detect the light stimulus in the shape of the red square with the side 2 mm, formed on the screen of CRT display, are given.
Źródło:
Acta Physica Polonica A; 2014, 125, 6; 1367-1370
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-9 z 9

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies