Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Wojtas, J." wg kryterium: Autor


Wyświetlanie 1-3 z 3
Tytuł:
Two-Channel Optoelectronic Sensor Employing Cavity Enhanced Absorption Spectroscopy
Autorzy:
Wojtas, J.
Powiązania:
https://bibliotekanauki.pl/articles/1493278.pdf
Data publikacji:
2011-10
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
07.07.Df
42.25.Dd
42.55.Px
42.60.Da
42.62.Fi
Opis:
In the paper, a description of two-channel of optoelectronic sensor basing on cavity enhanced absorption spectroscopy is presented. In contrast to the typical cavity enhanced absorption spectroscopy systems, here a special optical system is applied. It provides possibility to direct more than one beam of laser radiation into a cavity. Thus, special lasers controller system and photoreceiver were developed as well. The setup includes two pulsed laser diodes. The optical signals from the lasers are registered with one special constructed photoreceiver, which is characterized by wide range of the detected wavelengths. Moreover, there was applied time division multiplexing technique, well-known in the telecommunication systems. Every laser is assigned to the suitable channel - the strictly determined temporary window. In this window, the signal from the exits of the optical cavity is registered. In the system, optical signal from many laser sources can be measured and value of absorption coefficient at a few different wavelengths can be determined parallel. Typical cavity enhanced absorption spectroscopy system is designed to measure only one gas concentration, while the developed setup provides possibility to detect a trace concentration of two gases at the same time.
Źródło:
Acta Physica Polonica A; 2011, 120, 4; 763-766
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nitrogen Oxides Optoelectronic Sensors Operating in Infrared Range of Wavelengths
Autorzy:
Wojtas, J.
Bielecki, Z.
Stacewicz, T.
Mikolajczyk, J.
Rutecka, B.
Medrzycki, R.
Powiązania:
https://bibliotekanauki.pl/articles/1399410.pdf
Data publikacji:
2013-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
07.07.Df
42.25.Dd
42.55.Px
42.60.Da
42.62.Fi
85.60.-q
Opis:
Investigation of nitric oxide and nitrous oxide optoelectronic sensors is described. The detection of both components was done by measurement of absorption that occurs due to transition between vibronic molecular transitions. The improvement of the sensitivity was achieved due to application of cavity enhanced absorption spectroscopy. Two optical cavities (each one for each gas) built of high reflectance spherical mirrors were used. While the spectra of observed transitions are situated in mid-infrared range, two single mode quantum cascade lasers were applied. Their narrow emission lines were precisely tuned to the absorption lines of both investigated gases. The measurement of different mixtures of $Ar-NO$ and $Ar-N_2O$ within the range from 100 ppb to 10 ppm was performed. The relative uncertainty of the results did not exceed the level of 13%.
Źródło:
Acta Physica Polonica A; 2013, 124, 3; 592-594
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of Quantum Cascade Lasers in Nitric Oxide and Nitrous Oxide Detection
Autorzy:
Wojtas, J.
Bielecki, Z.
Stacewicz, T.
Mikolajczyk, J.
Medrzycki, R.
Rutecka, B.
Powiązania:
https://bibliotekanauki.pl/articles/1493346.pdf
Data publikacji:
2011-10
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
07.07.Df
42.25.Dd
42.55.Px
42.60.Da
42.62.Fi
Opis:
Application of quantum cascade lasers in NO and $N_2O$ sensor is described. Cavity enhanced absorption spectroscopy was used for this purpose. The detection was performed at vibronic molecular transitions in spectral regions of 5.23-5.29 μm and 4.46-4.54 μm for NO and $N_2O$, respectively. In order to avoid interferences by the gases contained in atmosphere $(H_2O, CO_2)$ the lines of 5.263 μm for NO and 4.530 μm for $N_2O$ were selected. Our two channel sensor is designated for simultaneous detection of both compounds. Each channel consists of single mode quantum cascade laser, optical cavity, and a photodetection module. The lasers were precisely tuned to the wavelength of interest. Optical cavities were built with spherical mirrors of high reflectance. The signals from the cavities outputs were registered with specially developed low noise detection modules.
Źródło:
Acta Physica Polonica A; 2011, 120, 4; 794-797
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies