Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "positron lifetime spectra" wg kryterium: Wszystkie pola


Wyświetlanie 1-3 z 3
Tytuł:
Discrete and Continuous Analysis of Positron Lifetime Spectra: a Comparison
Autorzy:
Consolati, G.
Quasso, F.
Powiązania:
https://bibliotekanauki.pl/articles/2007998.pdf
Data publikacji:
1999-04
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
36.10.Dr
71.60.+z
78.70.Bj
Opis:
Positron lifetime spectra in poly[1-(trimethylsilyl)]propine membranes were collected at different temperatures and various number of accumulated counts, in order to compare the results from analyses obtained by different decay models: discrete (that is, purely exponential) or continuous (with at least one distribution of lifetimes). Analysis into four discrete components is inadequate, unless a low number of counts (1 to 2 millions) is accumulated. Conversely, deconvolutions which allow the ortho-positronium lifetime to be distributed give satisfactory fits, even at the highest statistics (60 millions). An equivalent good fit in terms of χ$\text{}^{2}$ test is obtained with a five discrete components analysis, from which it is possible to extract information on the first moments (centroid and standard deviation) of ortho -positronium lifetime distribution.
Źródło:
Acta Physica Polonica A; 1999, 95, 4; 505-508
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement and Analysis of the Positron Annihilation Lifetime Spectra for Mesoporous Silica
Autorzy:
Zaleski, R.
Powiązania:
https://bibliotekanauki.pl/articles/2047164.pdf
Data publikacji:
2006-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
78.70.Bj
36.10.Dr
61.43.Gt
81.07.-b
41.75.Fr
Opis:
Positron annihilation lifetime spectroscopy as a technique of porous materials investigation is still under development. Both measurement conditions and lifetime spectra analysis methods have to be adapted to the requirements of positron porosimetry. If complex positron annihilation lifetime spectra of porous materials are processed, numerical methods of lifetime spectra analysis have to be used with a particular care. Among various methods of positron annihilation lifetime spectra analysis available, the most popular ones were tested implemented in programs MELT and LT. It was found, from the simulated spectra study, that a large number of counts in a spectrum is needed to obtain reliable results of analysis. Even then only an approximate solution is available. Determination of the approximation nature helps in a further interpretation of the results and in positron annihilation lifetime spectrometer setting adequate to the problem. For this purpose, a few complex spectra obtained from positron beam facility were tested. The results show a negligible influence of resolution function on long lifetime components, while the precise estimation of the background level is crucial. Also some distortions caused by imperfection of numerical analysis methods are pointed out.
Źródło:
Acta Physica Polonica A; 2006, 110, 5; 729-738
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Influence of the Temperature on Positron Annihilation Lifetime Spectra in Porous Sol-Gel Glass Doped with Ag Nanoparticles
Autorzy:
Gorgol, M.
Jasińska, B.
Reisfeld, R.
Levchenko, V.
Powiązania:
https://bibliotekanauki.pl/articles/1196126.pdf
Data publikacji:
2014-03
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
78.70.Bj
36.10.Dr
65.60.+a
61.43.Gt
Opis:
Silver nanoparticles with continuous size distribution from 10 to 20 nm were incorporated into porous glass produced using sol-gel technique. Positron annihilation lifetime spectroscopy was used to compare obtained material with an undoped reference glass. The positron annihilation lifetime spectroscopy measurement were made in a broad temperature range (from - 180C to 200°C). The experimental lifetime values were compared with the predictions of the extended Tao-Eldrup model of the temperature range. Experimental results for the reference material were in agreement with the model, except for a small discrepancy at low temperatures. In doped material substantial changes and non-monotonous temperature dependences of intensity and lifetime values were observed. Heating the material to 200C resulted in reorganization of the material structure.
Źródło:
Acta Physica Polonica A; 2014, 125, 3; 778-781
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies