Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Akkurt, I." wg kryterium: Autor


Wyświetlanie 1-3 z 3
Tytuł:
Determination of natural radioactivity and associated radiological hazard in excavation field in Turkey (Oluz Höyük)
Autorzy:
Çetin, B.
Öner, F.
Akkurt, İ.
Powiązania:
https://bibliotekanauki.pl/articles/1070198.pdf
Data publikacji:
2016-07
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
29.40.-n
29.85.Fj
Opis:
The level of natural radioactivity may be varied with the increase in dependence of the depth into the earth. In present study, soil samples from different depths were collected in Oluz Höyük excavation area. The radionuclide concentrations in soil samples were determined by gamma-ray spectrometer which contains 3" × 3" NaI(Tl) detector connected to multichannel analyser. The photopeaks at 1460, 1764, and 2615 keV due to ⁴⁰K, ²²⁶Ra and ²³²Th, respectively, have been used. The obtained activity concentrations of ⁴⁰K, ²²⁶Ra and ²³²Th ranged from 656.03 to 1791.85 Bq/kg, 62.39 to 180.93 Bq/kg and 48.31 to 125.43 Bq/kg, respectively. To assess the radiological hazard of the natural radionuclides content in the soil samples of these area, the radium equivalent activities (the minimum value was 181.99 Bq/kg and the maximum value was 497.97 Bq/kg), the absorbed dose rate (the minimum value was 86.83 nGy/h and the maximum value was 237.22 nGy/h), annual effective dose rate (the minimum value was 0.11 mSv/y and the maximum value was 0.29 mSv/y) and external hazard index (the minimum value was 0.49 and the maximum value was 1.35) were calculated using measured activities.
Źródło:
Acta Physica Polonica A; 2016, 130, 1; 475-478
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Calculation of Detection Efficiency for the Gamma Detector using MCNPX
Autorzy:
Akkurt, İ.
Tekin, H.
Mesbahi, A.
Powiązania:
https://bibliotekanauki.pl/articles/1402379.pdf
Data publikacji:
2015-08
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
87.10.Rt
29.40.-n
Opis:
Radiation detection has been a main interest for researchers as all kind of produced particles in atomic and subatomic physics based on the measurement systems so-called detector. Detection efficiency is one of the main parameter in detection system besides many other different parameters of the detector. The absolute efficiency of the gamma detector system will be used at Turkish Accelerator and Radiation Laboratory at Ankara (TARLA) is simulated using MCNPX code (version 2.4.0). The MCNP is the general purpose MC code that can be used for neutron, photon, electron or coupled neutron, photon, electron transport. The results have been obtained for NaI(Tl) detector system and compared with the experimental results. A good agreement was found between calculation and experiment.
Źródło:
Acta Physica Polonica A; 2015, 128, 2B; B-332-B-334
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Variation of Energy Resolution with Distance for a NaI(Tl) Detector
Autorzy:
Akkurt, İ.
Arda, S.
Gunoglu, K.
Powiązania:
https://bibliotekanauki.pl/articles/1402489.pdf
Data publikacji:
2015-08
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
29.40.-n
29.30.Kv
Opis:
As the nuclear radiation has started to be used in a variety of different fields, it is important to be protected from it, and thus the radiation measurement becomes vital. The quality of the performance of a detection system, used for the energy measurements, is important. It is characterized by the width of the pulse-height distribution, obtained for the particles of the same energy (monoenergetic source). The energy spectrum of a radiation source depends on the type and energy of the incident particle and the type of the detector. In this work the energy resolution of a 3"×3" NaI(Tl) detector has been measured for photon energies of 511, 662, 835, 1173, 1275, and 1332 keV, and its variation with the detector-source distance was investigated. The energy resolution of a detector system is obtained from the peak full width at one-half of the maximum height (FWHM) of a single peak (for a particular energy) as a function of detector-source distance. It was found that the energy resolution has decreased with the increasing distance.
Źródło:
Acta Physica Polonica A; 2015, 128, 2B; B-422-B-423
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies