Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "46.40.-f" wg kryterium: Temat


Wyświetlanie 1-7 z 7
Tytuł:
Hand Grip-EMG Muscle Response
Autorzy:
Barański, R.
Kozupa, A.
Powiązania:
https://bibliotekanauki.pl/articles/1197533.pdf
Data publikacji:
2014-04
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
46.40.-f
07.10.-h
Opis:
One of the most important factors in hand-arm system research is the information about hand grip force and pressing force on a tool handle. This article focuses on an alternative method to measure grip force. For grip force, one of the most popular solutions is a special handle with force sensors. However, when we want to use it with regular hand tool like e.g. a drill, it seems to be uncomfortable because we must interfere in handle construction. A solution proposed in this article is based on technique for evaluating and recording the electrical activity produced by muscles, electromyography (EMG). It has been assumed that EMG signal will be proportional to muscle tension responsible for palm grip. This solution have one significant advantage when comparing to special handle. It can be used with regular tool without interfering in the handle. Measurement presented in this article have been carried out with use of surface electromyography (sEMG). It is not invasive method which enables to measure EMG signal through placing stickers with electrodes directly on a skin.
Źródło:
Acta Physica Polonica A; 2014, 125, 4A; A-7-A-10
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Spectral Response of Hand-Arm System
Autorzy:
Barański, R.
Batko, W.
Powiązania:
https://bibliotekanauki.pl/articles/1504183.pdf
Data publikacji:
2011-06
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
07.10.-h
46.40.-f
Opis:
Recently we have used better solution to protect hand tool operators. In spite of our good intentions there is still endanger on high level vibration. For that reason we need to improve protection constantly. One of the most important properties of hand-arm system is knowledge about spectral response. In this article we try to obtain spectral response in narrow band-pass filters in accordance with IEC 1260:1995 and ANSI S1.11-2004 standards (implemented in LabVIEW software). To measure signals we used accelerometer placed on a wrist and on a tool. Of course the vibrations are attenuated by hand (cartilage, muscular tissue) but the question was what the shape of envelope in measurement range is. Our research used measurement on two different systems. The one was based on vibration inductor (laboratory environment), the second one used drill (real environment). This research is a part of a wider project to make virtual model of hand-arm system.
Źródło:
Acta Physica Polonica A; 2011, 119, 6A; 913-915
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Searching for New Measurement Solutions in the Area οf Estimating Danger of Local Vibrations at Workplace
Autorzy:
Barański, R.
Powiązania:
https://bibliotekanauki.pl/articles/1537332.pdf
Data publikacji:
2010-07
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
07.10.-h
46.40.-f
Opis:
There is a lot of controversy when we consider the most popular method of measuring local vibrations to estimate danger on hand tools operators. This is because of commonly used adapter that represents many faults, from which the most significant are: strong impact of grip and placing adapter between a hand and a tool handle. What we propose in this article is a measurement system including a band placed on a wrist. This solution highly eliminates defects mentioned above, but seems to be too trivial to maintain high quality of measuring process. The purpose of this article is to estimate the quality of this new solution in respect of some basic categories in which measurement errors occur.
Źródło:
Acta Physica Polonica A; 2010, 118, 1; 3-6
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of the Vibroacoustic Climate inside the Buses Solaris Urbino 18 Used in Public Transport Systems - Drivers Cab
Autorzy:
Damijan, Z.
Skrzyniarz, S.
Kwaśniewski, J.
Powiązania:
https://bibliotekanauki.pl/articles/1504428.pdf
Data publikacji:
2011-06
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
89.40.-a
46.40.-f
07.10.-h
46.40.Cd
Opis:
Despite new technological solutions and attempts to improve the working conditions during driving of vehicles, city bus drivers are still exposed to negative impacts of noise and vibrations, causing stress, increased fatigue and leads to numerous diseases. Therefore it seems merited to investigate the acoustic climate and the working conditions during the operation of Solaris Urbino 18 vehicles, widely used in public transport systems. The main purpose of this research program was to show the impacts that the conditions at work might have on bus drivers or to demonstrate that these impacts do not exist. No extensive major research was done to investigate the influence of the conditions at work on functional stability of bus drivers. Investigation of vehicle vibroacoustic climate in working (normal) environment are led rarely. Measurements often are done in idle run or during ride at manoeuvring site only for 2-3 min. In this paper results of acceleration and noise in idle run are presented for 3 min measurement and for 3 h until ride. All measurements are done in working environment on streets of Tychy city with passengers on board. In this paper detailed numerical analysis of vibroacoustic parameters are presented. Physical parameters like noise spectral analysis in 1/3 octave frequency bands and histogram of acoustic pressure level in the driver's cabin are presented in results.
Źródło:
Acta Physica Polonica A; 2011, 119, 6A; 1068-1072
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A System for Determination of Areas Hazardous for Blind People Using Wave-vibration Markers - Final Conclusions and Technical Application
Autorzy:
Wiciak, J.
Borkowski, B.
Czopek, D.
Powiązania:
https://bibliotekanauki.pl/articles/1400101.pdf
Data publikacji:
2013-06
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.66.Wv
43.66.Yw
46.40.-f
07.10.-h
Opis:
The paper constitutes a summary of the work carried out under the research project entitled The development of the method for marking and identification of the spots dangerous and of special importance for vision impaired persons in the big city with use of the wave-vibration markers. This article discusses key researches conducted during the project, including review of influence of environmental sounds on orientation and mobility of blind and partially sighted people, results of vibration perception threshold measurement taken at the wrist of both hands, measurements of paraseismic vibrations and results of researches on annoyance, recognizability and easiness to learn of selected signals.
Źródło:
Acta Physica Polonica A; 2013, 123, 6; 1101-1105
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Studies on Infrasound Noise Emitted by Wind Turbines of Large Power
Autorzy:
Boczar, T.
Malec, T.
Wotzka, D.
Powiązania:
https://bibliotekanauki.pl/articles/1418027.pdf
Data publikacji:
2012-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.28.Dm
07.10.-h
46.40.-f
43.50.-x
43.50.+y
Opis:
The subject area of this article applies to study of infrasound signals generated by the work of modern wind turbines. Infrasound noise measurements were conducted in accordance with assumptions of the EN 61400-11 standard. The object of study was a newly commissioned wind farm with a total electrical power equal to 30 MW. The considered power station consisted of 15 new wind turbines, each with a capacity of 2 MW. Scope of the analysis performed included designation of time runs, depicting temporal changes, and designation of frequency spectra of the recorded infrasound signals. Evaluation of the impact of changes in wind speed was made. Moreover, the scope of analysis, performed in this field, concerned assessment of the impact on the obtained results values of meteorological parameters related to the applied measurement system. Values obtained from measurements were related to and compared with the limits specified in standards and regulations existing in this field.
Źródło:
Acta Physica Polonica A; 2012, 122, 5; 850-853
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement System for Parameter Estimation and Diagnostic of Ultrasonic Transducers
Autorzy:
Kluk, P.
Milewski, A.
Kardyś, W.
Kogut, P.
Michalski, P.
Powiązania:
https://bibliotekanauki.pl/articles/1399367.pdf
Data publikacji:
2013-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.35.-c
43.35.+d
43.38.+n
43.38.-p
84.37.+q
07.10.-h
46.40.-f
07.20.Dt
Opis:
The paper presents an architecture and design of measurement system and methods for parameter estimation and diagnostic of ultrasonic transducers used in ultrasonic welding and cutting systems manufactured by Tele and Radio Research Institute. The key element of the ultrasonic welding and cutting system is a high power ultrasonic transducer implemented as a sandwich transducer consisting of a stack of piezoelectric ceramic rings mounted between two masses. High quality welding and cutting demand predetermined frequency characteristic of transducer impedance. Also important are: high energy efficiency, high coupling coefficient, low dielectric loss, and the optimal radiation pattern. In order to manufacture high quality and long-life transducers the piezoelectric rings must be selected and the sandwich transducers diagnosed on the basis of their measured parameters. Presented measurement system takes advantage of the virtual instrument technique in the NI LabVIEW environment. It uses Agilent U2761A Function Generator, U2531A Data Acquisition Unit, and the linear amplifier to measure impedance frequency characteristic in the frequency range of 10 kHz to 100 kHz. Moreover, the system can measure the vibration amplitude in the range of 1 μm up to 100 μm, using an optical sensor, and the temperature of the transducer using a pyrometer sensor.
Źródło:
Acta Physica Polonica A; 2013, 124, 3; 468-470
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies