Tytuł:
Occurrence and Characteristics of Microplastics in Leachate at a Large Municipal Wastewater Treatment Plant
Autorzy:
Ormaniec, Paulina
Powiązania:
https://bibliotekanauki.pl/articles/27314832.pdf
Data publikacji:
2022
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
microplastic
wastewater treatment plant
leachate
mikroplastik
oczyszczalnia ścieków
odcieki
Opis:
Due to the widespread occurrence and the potential threat to the environment, plastic materials are currently a growing problem of environmental protection in the world. Plastics whit dimensions not exceeding 5 mm are called microplastics. One of the main sources of microplastics in the aquatic environment are municipal wastewater treatment plants. The paper presents the results of research on the presence of microplastics in leachate from sludge processing at a large municipal wastewater treatment plant. The leachate was divided into the leachate produced in the processes of sludge thickening and dewatering. The analysis of the isolated microplastics included a physical analysis, which focuses on determining size, shape, and color of the isolated material. The next step was the chemical identification of the microplastic, where the type of polymer of the tested material was confirmed by means of Attenuated Total Reflection Fourier Transform Infrared. Among the isolated microplastic particles, almost a half was identified as fragments, and a smaller amount was confirmed for the presence of foil, fibers, foams and granules. The identified particles were plastic materials, including polypropylene, polyethylene, polystyrene or poly(terephthalate). Based on the results of the conducted research, the mass of microplastics in leachate was characterized and determined.
Źródło:
Civil and Environmental Engineering Reports; 2022, 32, 4; 105--115
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ prędkości przepływu i stężeń poszczególnych jonów na odkładanie się struwitu z roztworów wodnych na wewnętrznych powierzchniach rurociągów stalowych przy pH=9,5
Effect of velocity and concentration of individual ions on the deposition of struvite from aqueous solutions on the internal surfaces of steel pipes at ph = 9.5
Autorzy:
Czajkowska, J.
Powiązania:
https://bibliotekanauki.pl/articles/372008.pdf
Data publikacji:
2013
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
struwit
oczyszczalnia ścieków
fermentacja beztlenowa osadów
struvite
wastewater treatment plant
Opis:
Ze względu na specyfikę procesów zachodzących podczas beztlenowej fermentacji osadów na wielu oczyszczalniach stosujących tę metodę stabilizacji zauważono problem powstawania związków trudno rozpuszczalnych. Okazało się, że jest to najczęściej fosforan amonowo-magnezowy popularnie nazywany struwitem. Aby zbadać na ile istotny jest wpływ prędkości przepływu roztworu na odkładanie się struwitu na wewnętrznych powierzchniach rurociągów stalowych wykonano badania eksperymentalne wykorzystując przygotowaną do tego celu instalację. Zmiennymi niezależnymi były prędkość przepływu (0,40, 0,90 i 1,40 m/s) oraz skład roztworu, natomiast parametrem badanym była masa odkładającego się struwitu. Badania wykonano dla stałego pH=9,5. W badanym zakresie zaobserwowano gwałtowny wzrost osadzania materiału badawczego wraz ze spadkiem prędkości przepływu.
Due to the nature of processes taking place during the anaerobic digestion of sewage sludge on many using this method of stabilization observed the emergence of the problem of sparingly soluble compounds. It turned out that it is mostly magnesium ammonium phosphate, commonly known as struvite. To investigate how important is the impact velocity solution for the deposition of struvite on the inner surfaces of steel pipes suitable experimental studies were performed using the set for this purpose the installation. The independent variables are the flow rate (0.40, 0.90 and 1.40 m / s) and the composition of the solution, and the parameter considered was the mass produced struvite. The tests were performed for a constant pH = 9.5. During the study observed a sharp increase in the deposition of test material with decreasing velocity.
Źródło:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski; 2013, 152 (32); 105-112
1895-7323
Pojawia się w:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowoczesna oczyszczalnia ścieków w gminie Łagów Lubuski - pierwsze miesiące eksploatacji
The modern wastewater treatment plant in Lagow community - first months of the operation
Autorzy:
Sadecka, Z.
Myszograj, S.
Sieciechowicz, A.
Suchowska-Kisielewicz, M.
Waś, J.
Musiałowicz, T.
Powiązania:
https://bibliotekanauki.pl/articles/372203.pdf
Data publikacji:
2012
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
oczyszczalnia ścieków
usuwanie związków biogennych
wastewater treatment plant
removal of nutrients
Opis:
Wybór technologii, szczególnie w przypadku małych obiektów powinien zapewnić oczyszczanie ścieków w zakresie usuwania związków organicznych. W przypadku odprowadzania ścieków oczyszczonych do odbiorników I klasy czystości, technologia powinna zagwarantować również usuwanie ze ścieków związków azotu i fosforu. W artykule wykazano, że w nowej oczyszczalni ścieków obsługującej gminę Łagów Lubuski, uzyskuje się parametry ścieków oczyszczonych poniżej wartości wymaganych w Rozporządzeniu Ministra Środowiska (Dz.U. 2006 nr 137, poz. 984 z późn. zm). Wysoką efektywność oczyszczania ścieków z usuwaniem związków biogennych uzyskano przy energochłonności rzędu 0,4 kWh na 1 m3 dopływających ścieków.
The choice of technology, particularly in the case of small objects should provide a highly effective wastewater treatment with the removal of nitrogen and phosphorus. The paper shows that the new wastewater treatment for community Łagow Lubuski, allows to achieved parameters in treated wastewater below the required given in the regulation of the Minister of the Environment (Journal of Laws of 2006, No. 137, item 984). High efficiency of removal of nutrients can be obtained with energy consumption of 0.4 kWh per 1 m3 of sewage.
Źródło:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski; 2012, 145 (25); 84-94
1895-7323
Pojawia się w:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effectiveness of Pollutant Removal At the Wastwewater Treatment Plant in Goleniów
Autorzy:
Jakubaszek, Anita
Powiązania:
https://bibliotekanauki.pl/articles/2051690.pdf
Data publikacji:
2021
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
wastewater treatment
modernization
wastewater treatment plant
Wastwewater Treatment Plant in Goleniów
oczyszczanie ścieków
modernizacja
oczyszczalnia ścieków
Oczyszczalnia Ścieków w Goleniowie
Opis:
The article assesses the efficiency of pollutant removal at the sewage treatment plant in Goleniów after modernization of the technological system. The extension and modernization of the existing installation resulted from the need to adapt the treatment plant to accept larger loads of pollutants, improve the parameters of treated sewage discharged to the receiver, and the poor technical condition of the equipment. Before the modernization of the treatment plant, an increase in the loads of COD, BOD5, and periodic total suspended solids in raw sewage was observed as well as a reduction in the efficiency of removing pollutants from the sewage. The efficiency of removing pollutants after modernization was in the range of BOD5 - 94.4 ÷ 99.8%, COD - 89.3 ÷ 98.9%, total suspended solids TSS - 95.3 ÷ 99.7%, total nitrogen - 64.1 ÷ 95.4%, and total phosphorus - 75.4 ÷ 99.4%.
Źródło:
Civil and Environmental Engineering Reports; 2021, 31, 3; 251-264
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pollutants Removal Efficiency in The Hydroponic Lagoon of The Wastewater Treatment Plant
Autorzy:
Jakubaszek, Anita
Powiązania:
https://bibliotekanauki.pl/articles/27314840.pdf
Data publikacji:
2022
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
wastewater treatment plant
wastewater treatment
hydroponic lagoon
mechanical-biological wastewater
oczyszczalnia ścieków
oczyszczanie ścieków
laguna hydroponiczna
oczyszczanie mechaniczno-biologiczne
Opis:
Wastewater treatment in semi-natural systems, such as a hydroponic lagoon operating as the third stage of treatment, is becoming more and more popular because of the efficiency of organic matter and nutrient removal. The article presents an analysis of the efficiency of pollutant removal at the mechanical-biological wastewater treatment plant in Gronów with a capacity of Qd = 1125m3/day and a load of 9375 PE. The wastewater treatment plant operates on the basis of activated sludge and biomass settling technology on submerged flow beds. The treatment plant is characterized by a very high variability of wastewater inflow during the year due to periodic inflow of wastewater from tourist resorts in Łagów. The average efficiency of removing pollutants from wastewater was: BOD5 - 98.5%, COD - 92.8%, total suspended solids - 93.2%, total nitrogen - 86.1% and total phosphorus - 69.5%. The study showed that the use of a hydroponic lagoon in the technological system improved the efficiency of wastewater treatment by 1.7% for BOD5, 0.9% - COD, total suspended solids by 4.3%, 6.4% for total nitrogen and total phosphorus - 3.3%.
Źródło:
Civil and Environmental Engineering Reports; 2022, 32, 4; 293--305
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of reliable concentrations of pollutants in raw wastewater based on different sampling methods
Wyznaczanie miarodajnych stężeń zanieczyszczeń w ściekach surowych w oparciu o różne metody poboru próbek
Autorzy:
Myszograj, S.
Sadecka, Z.
Qteishat, O.
Suchowska-Kisielewicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/396193.pdf
Data publikacji:
2013
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
sampling methods
raw sewage
wastewater treatment plant
metody poboru próbek
ścieki
analiza ścieków
oczyszczalnia ścieków
Opis:
The aim of this study was to check the extent to which the sampling method and the volume of sewage (size of the wastewater treatment plant) influence the determined daily average concentrations of pollution components. Within three days of dry weather, the composition of two raw sewage wastewater treatment plants was continuously monitored. The WWTPs were designed for the flow of 820 m3d and 51000 m3d, respectively. The concentrations of pollutants were measured in samples taken both in time-proportional and flow-proportional ways. The obtained values show the possibility of taking the samples mixed at equal time intervals and in proportion to the flow as reliable sources for design values of concentrations. The size of WWTP, i.e. the amount of investigated raw sewage, was of no significant importance to the obtained results regarding concentrations of pollutants.
Nowelizacja i dostosowywanie przepisów prawnych do wymagań UE wymusza na eksploatatorach oczyszczalni ścieków wykonywanie precyzyjnych pomiarów ilości i analiz składu fizyko-chemicznego ścieków. Postęp techniczny oraz bogata oferta producentów urządzeń umożliwia sprostanie tym wymaganiom. Jednak o przydatności wyników pomiarowych do projektowania oczyszczalni ścieków obok dokładności urządzeń pomiarowych decyduje fakt, czy próbkę ścieków można uznać za próbkę reprezentatywną. Często pomimo najnowocześniejszych urządzeń i wykwalifikowanego personelu wyniki badań nie mogą być traktowane wiarygodnie. W artykule na podstawie pomiarów ilości i analiz składu ścieków surowych zweryfikowano w jakim stopniu metoda poboru próbek oraz ilość dopływających ścieków (wielkość oczyszczalni ścieków) wpływa na wartość wyznaczonych średniodobowych stężeń wskaźników zanieczyszczeń. W ciągu trzech dób w pogodzie suchej przeprowadzono ciągły monitoring składu ścieków surowych w oczyszczalniach zaprojektowanych na przepływ 820 m3d (OŚ1) i 51000 m3d (OŚ2). W próbkach zbieranych czasowo-proporcjonalnie i przepływowo-proporcjonalnie wyznaczono stężenia miarodajne wskaźników zanieczyszczeń. Uzyskane wartości wskazują na możliwości przyjmowania do projektowania stężeń miarodajnych wyznaczonych w próbkach zlewanych w jednakowych interwałach czasowych, jak i proporcjonalnie do przepływu. Nie stwierdzono również istotnego wpływu wielkości oczyszczalni, a tym samym nierównomierności dopływu ścieków surowych na obliczone wartości stężeń wskaźników zanieczyszczeń.
Źródło:
Civil and Environmental Engineering Reports; 2013, 10; 99-107
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Źródła ścieków dopływających do oczyszczalni w Kostrzynie nad Odrą
Sources of sewage flowing into wastewater treatment plant in Kostrzyn
Autorzy:
Mazurkiewicz, M.
Suchowska-Kisielewicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/372594.pdf
Data publikacji:
2012
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
oczyszczanie ścieków
obowiązki dostawcy ścieków
ścieki przemysłowe
wastewater treatment plant
obligations of suppliers of industrial
industrial wastewater
Opis:
Zgodnie z obowiązującymi regulacjami prawnymi jednostki samorządowe są zobowiązane do zapewnienia prawidłowego oczyszczania ścieków. Ten sam obowiązek dotyczy zakładów przemysłowych, które odprowadzają ścieki do kanalizacji lub stosują oczyszczalnie ścieków przemysłowych. W artykule przedstawiono dane dotyczące ilości i jakości ścieków przemysłowych dopływających do miejskiej oczyszczalni ścieków w Kostrzynie nad Odrą z uwzględnieniem ich wpływu na pracę oczyszczalni.
Źródło:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski; 2012, 148 (28); 24-34
1895-7323
Pojawia się w:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies