Wyszukujesz frazę "electrical impedance" wg kryterium: Wszystkie pola


Wyświetlanie 1-2 z 2
Tytuł:
Simulating electrical potential distribution by using "Spice" for electrical impedance tomography
Autorzy:
Biały, S.
Wróbel, Z.
Powiązania:
https://bibliotekanauki.pl/articles/333653.pdf
Data publikacji:
2002
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
elektryczna tomografia impedancyjna
zagadnienie proste
electrical impedance tomography
forward problem
model spice
Opis:
In this paper solution of straight problem was introduced in electrical impedance tomography with help of method of junction's potentials with utilisation of computer program "Spice". Preliminary investigations of model were introduced based on mesh of resistance artificially disturbances of schedule of resistance. Created images of boundary potentials permit onto estimation of errors introduced through model.
Źródło:
Journal of Medical Informatics & Technologies; 2002, 4; MT131-136
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of defibrillation treatment on some electrical parameters and application safety of ECG electrodes
Autorzy:
Ochocki, M.
Latos, S.
Powiązania:
https://bibliotekanauki.pl/articles/333268.pdf
Data publikacji:
2012
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
EKG
elektrody
defibrylacja
impedancja
bezpieczeństwo
ECG
electrodes
defibrillation
impedance
safety
Opis:
The subject of examination was mainly the determination of safety of available ECG electrodes use in conditions of defibrillation treatment in monitored patients. The electrodes of four European producers used in healthcare have been tested. For reason of periods of electrodes obtaining and their physical condition, the examinations have comprised four selected years and 7 types of electrodes. For testing needs, the electrodes were glued into pairs, in gel-to-gel mode. Testing was based on requirements of globally used American ANSI⁄AAMI EC 12:2000⁄(R)2010 standard for disposable ECG electrodes. For the electrodes pairs tested, determined was the influence of fourfold defibrillation release on polarization potential and their impedance measured with the current of 10 Hz frequency. It has been generally found that in result of fourfold exposition to defibrillating pulse the drop of impedance occurred in all tested, electrode pairs. For each electrodes series, mean value of this drop falls into interval of 10,8% to 57%. It was also pointed out that the ECG electrodes examined, while complying to requirements of the standard, allow the operator to perform the defibrillation procedure safely, including the possibility to fast evaluate the defibrillation result basing on ECG waveform recorded. Such general estimation of safety level of the available European ECG electrodes may be used as some reference in today very diversified market as to provenience end quality of products.
Źródło:
Journal of Medical Informatics & Technologies; 2012, 19; 133-139
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies