Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "storm" wg kryterium: Temat


Wyświetlanie 1-13 z 13
Tytuł:
Application of numerical modeling in analysis of the operation of a storm sewage system
Zastosowanie modelowania numerycznego w analizie pracy fragmentu sieci kanalizacji deszczowej
Autorzy:
Musz-Pomorska, Anna
Widomski, Marcin K.
Kępa, Jerzy
Powiązania:
https://bibliotekanauki.pl/articles/389494.pdf
Data publikacji:
2019
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
storm sewage system
Storm Water Management Model
quantitative analysis of storm sewage
qualitative analysis of storm sewage
sieć kanalizacji deszczowej
SWMM
analiza ilościowa ścieków deszczowych
analiza jakościowa ścieków deszczowych
Opis:
The increase in area of paved surfaces in cities, in relation to the natural permeable areas, results in increased loads of pollutants transported by the storm sewage system directly to the natural receivers. Storm wastewater, as it was reported in literature, in dependence to the type of urbanized basin and manner of drainage, contains significant concentration of pollutants, mainly: Total Suspended Solids (TSS), Total Nitrogen (TN), Total Phosphorus (TP), heavy metals and oil derivatives. In accordance with the Water Framework Directive, in many European countries, the alternative methods of managing rain sewage are being developed, allowing retention and purification of storm water at the place of its formation. In the case of existing storm swage networks, the numerical analysis of hydraulic conditions and quantitative assessment of transported pollutants may support actions taken to protect the natural ecosystems against the exceeding the permissible concentrations of pollutants. This paper presents the results of modeling of hydraulic parameters and quality conditions of storm wastewater in a selected part of the urban storm sewage system. The USEPA’s (United States Environmental Protection Agency) software SWMM 5 was applied to our studies. Three different rainfall events of various intensity and time duration were studied in our research. The conducted simulation tests enabled the analysis of the sewage flow rate, the canals filling height as well as the concentrations and loads of TSS, TP, TN at the outlet from the sewage system to the receiver. The results of the performed calculations showed that in the case of low-intensity rainfall, the unfavorable hydraulic conditions are present in the studied network. At the same time, the occurrence of storm event or extreme rainfall can lead to the flushing of deposits collected at the basin surface as well as at the bottom of pipes and the increase in loads of pollutants transported to the receiver.
Wzrost udziału powierzchni utwardzonych w stosunku do naturalnych powierzchni przepuszczalnych miast powoduje wzrost ładunków zanieczyszczeń przenoszonych przez system kanalizacji deszczowej bezpośrednio do odbiorników. Ścieki deszczowe, jak wykazują badania literaturowe, w zależności od sposobu wykorzystania odwadnianej powierzchni zurbanizowanej przenoszą znaczne ładunki zanieczyszczeń, głównie zawiesiny ogólnej, metali ciężkich czy związków ropopochodnych. Zgodnie z Ramową Dyrektywą Wodną w wielu krajach europejskich podejmowane są działania mające na celu rozwój alternatywnych metod zagospodarowania ścieków deszczowych, umożliwiających ich zatrzymywanie i oczyszczanie w miejscu ich powstawania. W przypadku istniejących już sieci deszczowych numeryczna analiza warunków hydraulicznych oraz ocena ilościowa transportowanych zanieczyszczeń może wspomóc działania podejmowane w celu ochrony naturalnych ekosystemów przed wzrostem/przekroczeniem dopuszczalnych stężeń zanieczyszczeń. W pracy zaprezentowano wyniki badań modelowych warunków hydraulicznych oraz jakościowych transportowanych ścieków deszczowych w wybranym fragmencie sieci deszczowej. Badania przeprowadzono w programie SWMM 5 przy założeniu zróżnicowanego natężenia deszczu oraz czasu jego trwania. Przeprowadzone badania symulacyjne umożliwiły analizę prędkości przepływu ścieków, wysokości napełnienia ścieków w przewodach, a także stężeń i ładunków zanieczyszczeń zawiesiny ogólnej, fosforu i azotu na wylocie z układu kanalizacyjnego do odbiornika. Wyniki przeprowadzonych obliczeń wykazały, iż w sieci kanalizacji deszczowej w przypadku opadów o niewielkim natężeniu panują niesprzyjające warunki hydrauliczne. Jednocześnie występowanie deszczów burzowych czy ekstremalnych może prowadzić do wymywania osadów zgromadzonych na dnie przewodów i wzrostu zanieczyszczeń przenoszonych do odbiornika.
Źródło:
Ecological Chemistry and Engineering. A; 2019, 26, 1-2; 73-83
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stężenia zanieczyszczeń w ściekach deszczowych dla wybranej zlewni miasta Lublin
Concentrations of pollutants in storm wastewater for selected catchment in Lublin, Poland
Autorzy:
Jaromin-Gleń, K. M.
Widomski, M. K.
Łagód, G.
Mazurek, W.
Powiązania:
https://bibliotekanauki.pl/articles/126685.pdf
Data publikacji:
2012
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
jakość wód opadowych
wskaźniki zanieczyszczeń
kanalizacja deszczowa
modelowanie numeryczne
quality of storm wastewater
pollution indicators
storm water drainage
numerical modeling
Opis:
Modelowanie numeryczne jakości ścieków opadowych staje się coraz bardziej popularnym i użytecznym narzędziem wykorzystywanym w celu oceny wpływu zanieczyszczeń transportowanych w kanalizacji deszczowej na wody odbiornika, którym z reguły są rzeki. Jednakże dokładność obliczeń numerycznych zależy bezpośrednio od zebranych i wprowadzonych do modelu danych wejściowych oraz prawidłowej jego kalibracji. Niezbędne dane wejściowe modelu obejmują charakterystyki oraz współczynniki równań empirycznych, dotyczące analizowanych zanieczyszczeń zmywanych ze zlewni. Praca przedstawia analizę stężeń wskaźników zanieczyszczeń w wodach deszczowych zrzucanych do rzeki Bystrzycy ze zlewni mającej swoje ujście przy ulicy Muzycznej w Lublinie w miesiącach letnich roku 2011. W zakres pracy wchodzą opis wybranych charakterystyk analizowanej zlewni oraz charakterystyka analizowanego opadu. Pomiary jakościowe ścieków deszczowych odprowadzanych do odbiornika obejmują ChZT, BZT5, mętność, barwę, zawiesinę ogólną, zawiesinę łatwo opadającą, stężenie O2, temperaturę oraz pH. Zmiany w jakości ścieków zostały omówione w zależności od właściwości deszczu. Prezentowane wyniki pomiarów są pierwszym krokiem na drodze budowy i kalibracji modelu komputerowego wymaganym dla miarodajnego prognozowania wpływu ścieków deszczowych analizowanej zlewni na jakość odbiornika - rzeki Bystrzycy.
Numerical modelling of storm wastewater quality becomes a very popular and useful tool in assessment of surface water runoff from urban areas impact on water bodies of sewage receivers, usually the rivers. However, reliability of qualitative numerical calculations results depends directly on the gathered input data to modeling and successful calibration of the developed model. Necessary input data cover description of the modeled rainfall event and coefficients for empirical equations describing pollutants buildup and washoff, while measurements of selected pollutants are required to model calibration. This paper presents analysis of pollutants concentration in storm wastewater discharged to the Bystrzyca River from the drainage system of Muzyczna St. basin, Lublin, Poland during the selected recent rainfall event in summer of 2011. The description of selected basin and characteristics of studied rainfall event were presented. Qualitative measurements of storm wastewater discharged from drainage system conducted in our research covered COD, BOD, turbidity, color, TSS, RSS, O2 concentration, temperature and pH. Changes of sewage quality in respect to various phases of rainfall event development were discussed. The presented results of measurements are the first step in model development and its calibration, required to successfully predict influence of discharged storm wastewater on quality of sewage receiver water body.
Źródło:
Proceedings of ECOpole; 2012, 6, 2; 725-730
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza krotności działania przelewów burzowych
Analysis of number of sewage discharges to the receiver
Autorzy:
Kaźmierczak, B.
Powiązania:
https://bibliotekanauki.pl/articles/127367.pdf
Data publikacji:
2013
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
przelew burzowy
kanalizacja ogólnospławna
modelowanie matematyczne
storm overflow
combined sewage system
mathematical modelling
Opis:
Przy projektowaniu przelewów burzowych należy uwzględniać ilościowe i/lub jakościowe kryteria ochrony wód odbiornika przed zanieczyszczeniem, wyrażone bądź to dopuszczalną liczbą zrzutów burzowych w ciągu roku (czasem ich trwania czy dopuszczalną objętością), bądź też dopuszczalnym stężeniem i/lub ładunkiem zanieczyszczeń, odprowadzanych w zrzutach burzowych do odbiornika. W przypadku przelewów burzowych obligatoryjnym kryterium ilościowym w Polsce jest limitowana wartość średniej rocznej liczby zrzutów ścieków, uzależniona od rodzaju kanalizacji oraz odbiornika. Dotychczasowe metody wymiarowania przelewów burzowych nie uwzględniają częstości zrzutów burzowych do odbiornika, jak też nie dają możliwości określenia czasu ich trwania oraz objętości, a przez to i ładunku zanieczyszczeń odprowadzanych w zrzutach do odbiorników. Symulacje działania przelewów burzowych pozwalają określić te parametry dla zaprojektowanego już przelewu i dowolnie zadanego obciążenia. Są więc cennym narzędziem wspomagającym proces projektowania tego typu obiektów, co wykazano w pracy.
While designing storm overflows, qualitative, as well as quantitative criteria of the receiver water protection must be taken into consideration. The criteria can be expressed by the allowed number of storm discharges during the year (their duration or allowed volume), or by the admissible concentration and/or the load of pollution drained off in storm discharges to the receiver. In case of storm overflows, the limited value of the average annual number of sewage discharges, depending from the type of sewerage system and the receiver constitutes an obligatory quantitative criterion in Poland. Current methods of designing storm overflows do not take into account the frequency of storm discharges to the receiver, as well as they do not offer the possibility of their duration and volume determination and thus they do not allow for the assessment of pollution load that is drained off in discharges towards receivers. The simulations of storm overflows functioning allow for determination of these parameters for already designed storm overflows. Therefore they constitute a valuable instrument supporting the process of designing this type of objects, as it has been proved in this work.
Źródło:
Proceedings of ECOpole; 2013, 7, 2; 617-625
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelling of discharges from storm overflows on a combined sewage system
Modelowanie zrzutów ścieków z przelewów burzowych na kanalizacji ogólnospławnej
Autorzy:
Kaźmierczak, B.
Powiązania:
https://bibliotekanauki.pl/articles/125805.pdf
Data publikacji:
2013
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
storm overflow
combined sewage system
mathematical modelling
przelew burzowy
kanalizacja ogólnospławna
modelowanie matematyczne
Opis:
A simulation of the functioning of a modern overfall with a throttling pipe on a combined sewage system was conducted in this work. For the modelling of storm overflow activity a combined drainage area of F = 50 ha was suggested. The overfall was loaded with sewage and wastewater. A typical, triangular hydrograph of the wastewater inflow to the storm overflow was applied here. The given hydraulic model of storm overflow activity includes a series of characteristic, occurring in sequence phases of filling and emptying of the overfall chamber. The phases were distinguished with the description of boundary conditions in reference to the precisely determined range of variables during the fillings and flows. On the basis of the formulated hydraulic and mathematical models of the storm overflow activity, a computer programme for the numerical simulation of the functioning of the aforementioned overflows was developed.
W pracy przeprowadzono symulację działania nowoczesnego przelewu z rurą dławiącą na kanalizacji ogólnospławnej. Na potrzeby modelowania działania przelewu burzowego zaproponowano modelową zlewnię ogólnospławną o powierzchni F = 50 ha. Przelew obciążono ściekami bytowo-gospodarczymi oraz deszczowymi. Założono typowy, trójkątny hydrogram dopływu ścieków deszczowych. Model działania przelewu burzowego ujmuje szereg charakterystycznych i występujących kolejno faz napełniania i opróżniania komory przelewowej, które zostały wyróżnione opisem warunków brzegowych w odniesieniu do ściśle określonego zakresu zmiennych w czasie napełnień i przepływów. Na podstawie sformułowanych modeli hydraulicznego i matematycznego funkcjonowania przelewów burzowych opracowano program komputerowy do numerycznej symulacji działania przedmiotowych przelewów.
Źródło:
Proceedings of ECOpole; 2013, 7, 1; 101-108
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania modelowe efektywności funkcjonowania separatora fazy stałej ścieków deszczowych
Modeling the efficiency of storm water solid phase separator
Autorzy:
Kozak, B.
Widomski, M. K.
Łagód, G.
Powiązania:
https://bibliotekanauki.pl/articles/126008.pdf
Data publikacji:
2014
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
separator fazy stałej
ścieki deszczowe
modelowanie numeryczne
solid phase separator
storm water
numerical modeling
Opis:
Odprowadzanie ścieków deszczowych z terenów zurbanizowanych związane jest z koniecznością przeciwdziałania zrzutowi znacznych ładunków zanieczyszczeń, w tym zawiesiny łatwo opadającej i ropopochodnych oraz tłuszczów, do odbiorników ścieków. W tym celu, przed skierowaniem ścieków do kanalizacji deszczowej, stosowane są różnego rodzaju separatory mające za zadanie oddzielić i zatrzymać fazy rozproszone - ciekłą i stałą. Efektywność ich pracy jest zatem miarą ochrony wód odbiorników ścieków deszczowych. Praca niniejsza przedstawia wyniki trójwymiarowych badań modelowych efektywności pracy prostego separatora fazy stałej oczyszczającego ścieki deszczowe. Badania modelowe zostały przeprowadzone w komercyjnym programie CFD Fluent Ansys Inc. Zaprezentowane obliczenia symulacyjne objęły przepływ ścieków deszczowych zawierających trzy frakcje fazy rozproszonej. Zastosowano trzy zróżnicowane prędkości przepływu ścieków deszczowych oraz trzy średnice ziaren fazy rozproszonej charakterystyczne dla frakcji piaskowej, pylastej i ilastej. Czas trwania odwzorowywanego zjawiska przepływu ścieków przez separator oraz zawartość procentową danej frakcji oparto o wartości charakterystyczne dla warunków lubelskich. Wyniki zaprezentowanych obliczeń numerycznych obejmowały rozkład prędkości przepływu wody i poszczególnych badanych frakcji przez separator, a także masę oraz rozkład przestrzenny zatrzymanych osadów w objętości zbiornika. Przeprowadzone badania umożliwiły ocenę skuteczności zatrzymywania poszczególnych frakcji oraz kształt objętości czynnej zbiornika separatora w funkcji prędkości przepływu. Ze względu na brak walidacji modelu otrzymane wyniki należy traktować jako wyniki badań wstępnych.
Storm water management in urbanized areas is directly connected to limiting the significant discharge of pollutants, including TSS, fats and oil derivatives, to the receivers. Thus, the various types of separators allowing to separate and retain the dispersed solid or liquid phase are applied before surface runoff waters enter the storm water system. Therefore, their efficiency is a measure of storm water receiver quality protection. This paper presents the results of three dimensional modeling studies concerning the operation efficiency of simple solid phase separator treating storm water. Our numerical researches were performed in the commercial CFD (computational fluid dynamics) software Fluent Ansys Inc. The presented numerical simulations covered flow of storm water containing there factions of dispersed fraction through the solid phase separator. Three velocities of flow and three particles’ dimensions representative for sand, silt and clay fractions were applied. Time duration of modeled storm water flow as well as percentage distribution of applied solid phases were based on values typical for Lublin region. Results of our numerical calculations covered velocities of flow distribution for storm water and tested solid phases as well as the accumulated masses and spatial development of retained solid phases particles inside the separator’s water body. The performed numerical simulations allowed assessment of retaining efficiency for the applied solid phase fraction and shape of separator’s active volume as a function of storm water velocity of flow. The lacking validation of our modeling attempt influences the fact that our studies should be treated as preliminary.
Źródło:
Proceedings of ECOpole; 2014, 8, 2; 542-547
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of numerical modeling in analysis of the operation of a storm sewage system
Zastosowanie modelowania numerycznego w analizie pracy fragmentu sieci kanalizacji deszczowej
Autorzy:
Musz-Pomorska, A.
Widomski, M. K.
Kępa, J.
Powiązania:
https://bibliotekanauki.pl/articles/127483.pdf
Data publikacji:
2018
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
storm sewage system
SWMM
quantitative and qualitative analysis
sieć kanalizacji deszczowej
analiza ilościowa i jakościowa
Opis:
The increase in paved surfaces area in cities, in relation to the natural permeable areas, results in increased loads of pollutants transported by the storm sewage system directly to the receivers. Storm wastewater, as it was reported in literature, in dependence to the type and of urbanized basin and manner of drainage contains significant concentration of pollutants, mainly: Total Suspended Solids (TSS), Total Nitrogen (TN), Total Phosphorus (TP), heavy metals and oil derivatives. In according with the Water Framework Directive, in many European countries, the alternative methods of managing rain sewage are being developed, allowing retention and purification of storm water at the place of its formation. In the case of existing storm swage networks, the numerical analysis of hydraulic conditions and quantitative assessment of transported pollutants may support actions taken to protect the natural ecosystems against the exceeding the permissible concentrations of pollutants. This paper presents the results of modelling of hydraulic parameters and quality conditions of storm wastewater in a selected part of the urban storm sewage system. The USEPA’s (United States Environmental Protection Agency) software SWMM 5 (Storm Water Management Model) was applied to our studies. Three different rainfall events of various intensity and time duration were studied in our research. The conducted simulation tests enabled the analysis of the sewage flow rate, the canals filling height as well as the concentrations and loads of TSS, TP, TN at the outlet from the sewage system to the receiver. The results of the performed calculations showed that in the case of low-intensity rainfall, the unfavourable hydraulic conditions are present in the studied network. At the same time, the occurrence of storm event or extreme rainfall can lead to the flushing of deposits collected at the basin surface as well as at the bottom of pipes and the increase in loads of pollutants transported to the receiver.
Wzrost udziału powierzchni utwardzonych w stosunku do naturalnych powierzchni przepuszczalnych miast powoduje wzrost ładunków zanieczyszczeń przenoszonych przez system kanalizacji deszczowej bezpośrednio do odbiorników. Ścieki deszczowe, jak wykazują badania literaturowe, w zależności od sposobu wykorzystania odwadnianej powierzchni zurbanizowanej przenoszą znaczne ładunki zanieczyszczeń, głównie zawiesiny ogólnej, ChZT, BZT, metali ciężkich czy związków ropopochodnych. Zgodnie z Ramową Dyrektywą Wodną w wielu krajach europejskich podejmowane są działania mające na celu rozwój alternatywnych metod zagospodarowania ścieków deszczowych, umożliwiających ich zatrzymywanie i oczyszczanie w miejscu ich powstawania. W przypadku istniejących już sieci deszczowych numeryczna analiza warunków hydraulicznych oraz ocena ilościowa transportowanych zanieczyszczeń może wspomóc działania podejmowane w celu ochrony naturalnych ekosystemów przed wzrostem/przekroczeniem dopuszczalnych stężeń zanieczyszczeń. W pracy zaprezentowano wyniki badań modelowych warunków hydraulicznych oraz jakościowych transportowanych ścieków deszczowych w wybranym fragmencie sieci deszczowej. Badania przeprowadzono w programie SWMM 5 przy założeniu zróżnicowanego natężenia deszczu oraz czasu jego trwania. Przeprowadzone badania symulacyjne umożliwiły analizę prędkości przepływu ścieków, wysokości napełnienia ścieków w przewodach, a także stężeń i ładunków zanieczyszczeń zawiesiny ogólnej, fosforu i azotu na wylocie z układu kanalizacyjnego do odbiornika. Wyniki przeprowadzonych obliczeń wykazały, iż w sieci kanalizacji deszczowej w przypadku opadów o niewielkim natężeniu panują niesprzyjające warunki hydrauliczne. Jednocześnie występowanie deszczów burzowych czy ekstremalnych może prowadzić do wymywania osadów zgromadzonych na dnie przewodów i wzrostu zanieczyszczeń przenoszonych do odbiornika.
Źródło:
Proceedings of ECOpole; 2018, 12, 2; 307-313
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Quantitative and Qualitative Numerical Analysis of Operational Conditions of Storm Water System
Ilościowa i jakościowa analiza numeryczna funkcjonowania sieci kanalizacji deszczowej
Autorzy:
Chmielewska, A.
Widomski, M. K.
Musz, M.
Łagód, G.
Mazurek, W.
Powiązania:
https://bibliotekanauki.pl/articles/388107.pdf
Data publikacji:
2013
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
storm sewer
numerical modeling
quantitative analysis
qualitative analysis
kanalizacja deszczowa
modelowanie numeryczne
analiza ilościowa
analiza jakościowa
Opis:
Operation of storm water systems in urbanized catchments, affected by increased size of drainaged area and its relative surface sealing, significant variability of rainfall events and increased usage of transport vehicles is connected to changes of sewage flow, pollutants concentrations and loads entering the sewage receiver. Thus, the application of numerical modeling to multi-variant analyses of storm water systems operation and its influence on the natural environment is reasonable and becomes a standard procedure nowadays. This paper presents the numerical modeling application to quantitative and qualitative analysis of storm-water sewer system in conditions of the selected urbanized area in the town of population reaching 40 000. The US EPA’s (United States Environmental Protection Agency) software SWMM 5 was applied to our studies. Three different rainfall events of various time and intensity were applied to our research. The presented analysis was based on sewage flow velocity, wastewater table height in the pipelines and the load of pollutants leaving the sewerage system. The sewage flooding from several chambers was observed. Our studies reveals also the fact that the studied system is partially undersized and the observed concentration of TSS entering the receiver exceeds the maximum value allowable by the local standards. According to the lacking model calibration, our observations should be treated as the preliminary studies.
Funkcjonowanie miejskich systemów kanalizacji deszczowej, na które wpływa wzrost powierzchni odwadnianej, zmienność opadów, zmiana stopnia uszczelnienia odwadnianych powierzchni oraz wzrost wykorzystywania transportu kołowego, związane jest z ciągłymi zmianami w przepływie ścieków, a także stężeniach i ładunkach zanieczyszczeń trafiających do odbiornika. Dlatego też standardem staje się wykorzystywanie modelowania numerycznego w wielowariantowej analizie warunków pracy oraz oddziaływania na środowisko kanalizacji deszczowej. W pracy przedstawiono próbę zastosowania modelowania numerycznego do ilościowej i jakościowej analizy warunków pracy kanalizacji deszczowej dla miejskiej jednostki osadniczej o liczbie mieszkańców wynoszącej 40 000 osób. Model sieci kanalizacji deszczowej rozpatrywanego miasta wykonano w programie SWMM5 opracowanym przez USEPA (United States Environmental Protection Agency). W badaniach modelowych wykorzystano trzy opady atmosferyczne charakteryzujące się różną intensywnością oraz czasem trwania opadu. Przedstawiona analiza została oparta na prędkościach przepływu ścieków, możliwości wypływu podpiętrzonych w studzienkach ścieków na powierzchnie terenu oraz ładunkach transportowanych zanieczyszczeń. Przeprowadzone badania wykazały możliwość wypływu ścieków ze studzienek połączeniowych lub rewizyjnych na powierzchnię odwadnianego terenu wynikające z częściowego niedowymiarowania badanego układu kanalizacyjnego. Odnotowano także przekroczenie aktualnych wartości dopuszczalnych stężenia zawiesiny ogólnej we wszystkich analizowanych wariantach obliczeń symulacyjnych. Ze względu na brak kalibracji modelu otrzymane wyniki należy traktować jako wyniki badań wstępnych.
Źródło:
Ecological Chemistry and Engineering. A; 2013, 20, 12; 1397-1410
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dimensioning of the sewerage system
Wymiarowanie kanalizacji deszczowej
Autorzy:
Kotowski, A.
Kaźmierczak, B.
Powiązania:
https://bibliotekanauki.pl/articles/126519.pdf
Data publikacji:
2013
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
sewer flooding
rain model
storm water management model
wylania z kanalizacji
opad modelowy
model zarządzania wodami opadowymi
Opis:
The paper presents verification of selected flow time methods in terms of usability for sewerage systems design and sizing on the example of a model municipal flat drainage area of 2 km2. Namely, the sewerage system network was sized using three methods, that is, MGN with Blaszczyk’s formula, MGN with the precipitation model for Wroclaw and MWO with the precipitation model for Wroclaw, and then, the network functioning was verified for damming up on the area surface and flooding from drains using the hydrodynamic model SWMM 5.0. It was shown that the safe flow time method for sewerage system sizing is MWO using the criterion for the lack of damming up for the area and flooding from drains.
W pracy symulowano działanie kanalizacji deszczowej zwymiarowanej trzema metodami czasu przepływu, tj.: MGN z wzorem Błaszczyka, MGN z wzorem opadów dla Wrocławia i MWO z wzorem opadów dla Wrocławia, dla modelowej zlewni miejskiej o powierzchni 2 km2 w terenie płaskim. Do symulacji hydrodynamicznych działania systemów kanalizacyjnych wybrano program SWMM 5.0 (Storm Water Management Model), opracowany przez Amerykańską Agencję Ochrony Środowiska (US EPA). Wskazano na bezpieczną metodę wymiarowania kanalizacji deszczowej (MWO) przy kryterium braku wylewów z kanałów.
Źródło:
Proceedings of ECOpole; 2013, 7, 1; 117-124
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical modeling in quantitative and qualitative analysis of storm sewage system operational conditions
Modelowanie numeryczne w ilościowej i jakościowej ocenie możliwości rozbudowy sieci kanalizacji deszczowej
Autorzy:
Chmielewska, A.
Widomski, M. K.
Musz, A.
Łagód, G.
Mazurek, W.
Powiązania:
https://bibliotekanauki.pl/articles/125799.pdf
Data publikacji:
2012
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
storm sewer
numerical modeling
quantitative and qualitative analysis
kanalizacja deszczowa
modelowanie numeryczne
rozbudowa sieci
analiza ilościowa i jakościowa
Opis:
Exploitation of urban storm-water systems, affected by increased size of drainaged catchment, high variability of rainfall events, changes in relative surface sealing as well as increased usage of road transport vehicles resulting in changes of sewage flow and pollutants concentrations as well as loads entering the sewage receiver, seems to be the challenging engineering problem. Thus, the application of numerical modeling to multi-variant analyses of storm-water sewer systems operation and its influence on the natural environment becomes a standard procedure nowadays. This paper presents the attempt of numerical modeling application to quantitative and qualitative analysis of storm-water sewer system in conditions of the selected urbanized catchment in the town of population reaching 40 000. The US EPA’s (United States Environmental Protection Agency) software SWMM 5 was applied to our studies. Three different rainfall events of various intensity and time were studied in our research. The presented analysis was based on sewage flow velocity, wastewater level along the pipelines and the load of pollutants leaving the sewer system. The sewage flooding from several join or inspection chambers was observed. Our studies reveal also the fact that the studied system is partially undersized. According to the lack of model calibration our observations should be treated as preliminary studies.
Przedstawiono próbę zastosowania modelowania numerycznego do ilościowej i jakościowej oceny możliwości rozbudowy systemu kanalizacji deszczowej. Model wybranego fragmentu sieci kanalizacyjnej miasta Chełm wykonano w programie SWMM 5. W badaniach przeanalizowano trzy warianty charakteryzujące się różną intensywnością oraz czasem trwania opadu. Obliczenia hydrauliczne wykonano dla warunków przed i po rozbudowie sieci. Przedstawiona analiza została oparta na prędkościach przepływu ścieków, napełnieniu kanałów oraz stężeniach i ładunkach transportowanych zanieczyszczeń. Po wykonaniu obliczeń symulacyjnych sieci po jej rozbudowie otrzymano wyniki, w których zaobserwowano zmiany w prędkości przepływu, napełnieniach kanałów, ładunkach badanego zanieczyszczenia. Odnotowano także w wynikach symulacji wypływ ścieków ze studzienek połączeniowych lub rewizyjnych na powierzchnię odwadnianego terenu. Przeprowadzone badania wskazują również, iż istniejący system zaprojektowany na podstawie wzoru Błaszczyka w obecnych warunkach jest częściowo przewymiarowany. W związku z tym prędkość samooczyszczania przewodów nie została osiągnięta w znacznej części sieci. Ze względu na brak kalibracji modelu otrzymane wyniki należy traktować jako wyniki badań wstępnych.
Źródło:
Proceedings of ECOpole; 2012, 6, 2; 487-492
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelowanie numeryczne w ilościowej i jakościowej ocenie możliwości rozbudowy sieci kanalizacji deszczowej
Numerical modeling in quantitative and qualitative analysis of extension of storm sewage system
Autorzy:
Gajuk, D.
Widomski, M. K.
Musz, A.
Łagód, G.
Powiązania:
https://bibliotekanauki.pl/articles/126153.pdf
Data publikacji:
2011
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
kanalizacja deszczowa
modelowanie numeryczne
rozbudowa sieci
analiza ilościowa i jakościowa
storm sewer
numerical modeling
network expansion
quantitative and qualitative analysis
Opis:
W pracy przedstawiono próbę zastosowania modelowania numerycznego do ilościowej i jakościowej oceny możliwości rozbudowy systemu kanalizacji deszczowej. Model wybranego fragmentu sieci kanalizacyjnej miasta Chełm wykonano w programie SWMM5. W badaniach przeanalizowano trzy warianty charakteryzujące się różną intensywnością oraz czasem trwania opadu. Obliczenia hydrauliczne wykonano dla warunków przed i po rozbudowie sieci. Przedstawiona analiza została oparta na prędkościach przepływu ścieków, napełnieniu kanałów oraz ładunkach transportowanych zanieczyszczeń. Po wykonaniu obliczeń symulacyjnych sieci po jej rozbudowie otrzymano wyniki, w których zaobserwowano zmiany w prędkości przepływu, napełnieniach kanałów, ładunkach badanego zanieczyszczenia. Odnotowano także w wynikach symulacji wypływ ścieków ze studzienek połączeniowych lub rewizyjnych na powierzchnię odwadnianego terenu. Przeprowadzone badania wskazują również, iż istniejący system zaprojektowany na podstawie wzoru Błaszczyka w obecnych warunkach jest częściowo przewymiarowany. W związku z tym prędkość samooczyszczania przewodów nie została osiągnięta w znacznej części sieci. Ze względu na brak kalibracji przedstawianego modelu otrzymane wyniki należy traktować jako wyniki badań wstępnych.
This paper presents the attempt of numerical modeling application to quantitative and qualitative analysis of storm-water sewer system extension in conditions of the selected urbanized catchment in Chelm, Poland. The USEPA’s (United States Environmental Protection Agency) software SWMM 5 was applied to our studies. Three different rainfall events of various intensity and time were studied in our research. Our calculations considered hydraulic operational conditions before and after attachment of new pipelines. The presented analysis was based on sewage flow velocity, wastewater level along the pipelines and the load of pollutants leaving the sewer system. The visible changes in flow velocity, discharged loads of selected pollutants and sewage outflow from several join or inspection chambers were observed after development of an existing sewer system. Our studies reveals also the fact that the existing system, designed basing on Blaszczyk’s formula is partially oversized, the velocity of pipes’ self-purification was not assured in the some part of studied network. The quality of our observations may be reduced by the lack of model calibration.
Źródło:
Proceedings of ECOpole; 2011, 5, 1; 209-215
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical Modeling in Quantitative and Qualitative Analysis of Storm Sewage System Extension
Modelowanie numeryczne w ilościowej i jakościowej ocenie możliwości rozbudowy sieci kanalizacji deszczowej
Autorzy:
Widomski, M.
Musz, A.
Gajuk, D.
Łagód, G.
Powiązania:
https://bibliotekanauki.pl/articles/387908.pdf
Data publikacji:
2012
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
kanalizacja deszczowa
modelowanie numeryczne
rozbudowa sieci
analiza ilościowa i jakościowa
storm sewer
numerical modeling
network expansion
quantitative and qualitative analysis
Opis:
This paper presents the attempt of numerical modeling application to quantitative and qualitative analysis of storm-water sewer system extension in conditions of the selected urbanized catchment in city of Chelm, Poland. The USEPA’s (United States Environmental Protection Agency) software SWMM 5 was applied to our studies. Three different rainfall events of various intensity and duration were studied in our research. Our calculations considered hydraulic operational conditions before and after attachment of new pipelines to the existing system. The presented analysis was based on sewage flow velocity, wastewater level along the pipelines and the load of pollutants leaving the sewer system. The visible changes in flow velocity, discharged loads of selected pollutants and sewage outflow from several join or inspection chambers were observed after development of the existing sewer system. Our studies reveals also the fact that the existing system, designed basing on Blaszczyk’s formula is partially oversized, the velocity of pipes’ self-purification was not assured in the some part of studied network. The quality of our observations may be reduced by the lack of model calibration.
W pracy przedstawiono próbę zastosowania modelowania numerycznego do ilościowej i jakościowej oceny możliwości rozbudowy systemu kanalizacji deszczowej. Model wybranego fragmentu sieci kanalizacyjnej miasta Chełma wykonano w programie SWMM5. W badaniach przeanalizowano trzy warianty charakteryzujące się różną intensywnością oraz czasem trwania opadu. Obliczenia hydrauliczne wykonano dla warunków przed i po rozbudowie sieci. Przedstawiona analiza została oparta na prędkościach przepływu ścieków, napełnieniu kanałów oraz stężeniach i ładunkach transportowanych zanieczyszczeń. Po wykonaniu obliczeń symulacyjnych sieci po jej rozbudowie otrzymano wyniki, w których zaobserwowano zmiany w prędkości przepływu, napełnieniach kanałów, ładunkach badanego zanieczyszczenia. Odnotowano także w wynikach symulacji wypływ ścieków ze studzienek połączeniowych lub rewizyjnych na powierzchnię odwadnianego terenu. Przeprowadzone badania wskazują również, iż istniejący system zaprojektowany na podstawie wzoru Błaszczyka, w obecnych warunkach jest częściowo przewymiarowany. W związku z tym prędkość samooczyszczania przewodów nie została osiągnięta w znacznej części sieci. Ze względu na brak kalibracji modelu otrzymane wyniki należy traktować jako wyniki badań wstępnych.
Źródło:
Ecological Chemistry and Engineering. A; 2012, 19, 4-5; 471-481
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania modelowe rozprzestrzeniania się zanieczyszczenia pochodzącego z nieszczelnej kanalizacji deszczowej w gruntach torfowych
Model study of pollutant transport stemming from leaking storm water system in peat soils
Autorzy:
Iwanek, M.
Widomski, M.
Krukowski, I.
Łagód, G.
Goral, E.
Powiązania:
https://bibliotekanauki.pl/articles/127101.pdf
Data publikacji:
2011
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
kanalizacja deszczowa
zanieczyszczenia w ściekach deszczowych
chlorek sodu
modelowanie matematyczne
storm water system
pollutions in rain wastewaters
sodium chloride
mathematical modeling
Opis:
Postępujący gwałtownie rozwój cywilizacyjny prowadzi do uszczelniania nawierzchni coraz większej powierzchni terenów zielonych zajmowanych na parkingi, chodniki i drogi. W większości przypadków tereny te wyposażane są w kanalizację deszczową, do której trafiają spłukiwane zanieczyszczenia. Jednym z zanieczyszczeń spłukiwanych z powierzchni utwardzonych, w szczególności w okresie zimowym, jest chlorek sodu. Zanieczyszczenia transportowane siecią kanalizacji deszczowej mogą przedostawać się do środowiska gruntowo-wodnego w przypadku awarii lub nieszczelności układu. Akumulacja zanieczyszczeń pochodzących z nieszczelnej kanalizacji deszczowej może negatywnie wpływać na środowisko naturalne, w szczególności na jakość wód gruntowych. Niniejsza praca przedstawia badania modelowe rozprzestrzeniania się zanieczyszczenia chlorkiem sodu pochodzącym z nieszczelnego kanału deszczowego poprowadzonego przez grunty torfowe. Przewidzenie zasięgu tego zjawiska oraz jego skutków jest zagadnieniem bardzo skomplikowanym, dlatego też do badań modelowych wykorzystano komercyjny program FEFLOW 5.2. Obliczenia numeryczne wykonano na podstawie parametrów przyjętych na podstawie badań terenowych, laboratoryjnych i dostępnej literatury. Uzyskane wyniki badań umożliwiają przeprowadzenie oceny wpływu rozpatrywanego zjawiska na środowisko naturalne. Wykonana analiza wymaga przeprowadzenia badań terenowych potwierdzających prawidłowość przyjętych założeń.
Rapid civilization development results in sealing of increased area of undeveloped terrains transformed into parking lots, pavements and roads. In most cases these basins are equipped with drainage system transporting the washed pollutants. One of the pollutants transported by surface run-off, particularly in winter, is sodium chloride. Pollutants transported in the network of the storm water system can enter the groundwater environment in case of the damage or the leak of the system. The pollutants leaving sewage system can accumulate and affect the environment and the quality of groundwater. This paper presents the model studies of the sodium chloride stemming in peat soil during failure of storm water system. Prediction of this phenomenon range and its results are very complicated problems, thus the commercial program FEFLOW 5.2., WASY was used in our model studies. The numerical calculations were performed on the basis of input data obtained by field and laboratory measurements as well as the available literature. The obtained results enabled the influence of the considered phenomenon on the environment to be estimated. The performed analysis demands validation confirming the correctness of the modeling assumptions.
Źródło:
Proceedings of ECOpole; 2011, 5, 1; 227-232
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of reed Phragmites australis on an efficiency of oil-derivatives removal
Wpływ trzciny pospolitej Phragmites australis na skuteczność usuwania zanieczyszczeń ropopochodnych
Autorzy:
Bergier, T.
Włodyka-Bergier, A.
Powiązania:
https://bibliotekanauki.pl/articles/126558.pdf
Data publikacji:
2016
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
storm water treatment
constructed wetlands
oil-derivatives
aliphatic hydrocarbons
reed Phragmites australis
hydrofitowe oczyszczanie wód deszczowych
ropopochodne
węglowodory alifatyczne
trzcina pospolita
Phragmites australis
Opis:
Constructed wetlands are the effective mean of stormwater management, also in a case of runoff from highways, parking lots and other surfaces contaminated with oil-derivatives, which are potential risk for environment, human health and biological wastewater treatment units. The mechanisms of oil-derivatives removal on wetland beds are complex and not fully understood, however the most important role seem to be played by adsorption on mineral filling, the activities of microorganisms and higher plants. The goal of the presented research is to evaluate the role of macrophytes in oil-derivatives removal processes, as well as to assess the plants’ resistance to the high concentrations of these pollutants. The research was conducted as pot experiments, with the usage of reed Phragmites australis and model solutions, simulating runoff from surfaces contaminated with oil-derivatives, in three concentrations (0.01, 0.02 and 0.05% of diesel fuel) and three detection times (24, 48 and 96 h). Both in raw and treated solutions, following parameters were measured: pH, conductivity, the sum of aliphatic hydrocarbons C7-C40 and their individual concentration. The research results were used to define the removal efficiency of the studied contaminates, especially oil-derivatives, on constructed wetlands beds, as well as to assess the macrophytes’ influence on these processes. The state and conditions of plants were also observed to assess their reaction on the examined concentrations of oil substances.
Oczyszczalnie hydrofitowe są efektywnym sposobem zagospodarowania wód deszczowych, w tym również spływów powierzchniowych z dróg, parkingów i innych powierzchni zanieczyszczonych związkami ropopochodnymi, które stanowią zagrożenie dla środowiska naturalnego, zdrowia ludzi, a także systemów biologicznego oczyszczania ścieków. Mechanizmy usuwania związków ropopochodnych przez złoża hydrofitowe są złożone i nie w pełni poznane, jednak najważniejszą rolę wydaje się pełnić adsorpcja na wypełnieniu mineralnym złoża, działanie mikroorganizmów w nim bytujących oraz aktywność roślin wyższych. Celem prezentowanych badań jest określenie wpływu roślinności na skuteczność usuwania zanieczyszczeń ropopochodnych, a także ocena odporności roślin na wysokie stężenia tych związków. Badania przeprowadzono w formie doświadczeń wazonowych z wykorzystaniem trzciny pospolitej (Phragmites australis) oraz ścieków modelowych, symulujących spływy powierzchniowe z powierzchni zanieczyszczonych ropopochodnymi, o trzech stężeniach (0,01, 0,02 i 0,05% oleju napędowego), dla trzech czasów retencji ścieków (24, 48 i 96 h). W ściekach surowych oraz w ściekach po odpowiednim czasie zatrzymania oznaczano następujące parametry: odczyn pH, przewodność elektryczną właściwą, sumę węglowodorów alifatycznych C7-C40 oraz stężenia pojedynczych węglowodorów z tej grupy. Wyniki tych badań posłużyły do określenia efektywności usuwania badanych zanieczyszczeń, w szczególności ropopochodnych, przez złoża hydrofitowe i do określenia wpływu roślinności w tym zakresie. Poza tym prowadzono obserwacje stanu i kondycji roślin, co pozwoliło określić ich odporność na badane stężenia związków ropopochodnych.
Źródło:
Proceedings of ECOpole; 2016, 10, 1; 19-25
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-13 z 13

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies