Wyszukujesz frazę "mechaniczne odwadnianie" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
The quality of sludge liquids produced in the process of mechanical dewatering of digested sludge
Jakość cieczy osadowych powstających w procesie mechanicznego odwadniania osadów przefermentowanych
Autorzy:
Bień, B.
Powiązania:
https://bibliotekanauki.pl/articles/389027.pdf
Data publikacji:
2017
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
sludge liquids
coagulants
polyelectrolytes
ultrasonic field
mechanical dewatering
ciecze osadowe
koagulanty
polielektrolity
pole ultradźwiękowe
mechaniczne odwadnianie
Opis:
The quality of sludge liquids produced in the processes of mechanical dewatering of sludge depends on the stabilization technology and the kind of device, its proper operation, and an appropriate choice of conditioning chemicals. The article presents the impact of selected conditioning chemicals and methods, such as: PIX 113, PIX 123, Zetag 8160 polyelectrolyte, ultrasonic field, and their combined effect on the properties of sludge liquids. crude sludge liquids were characterized by high concentrations of ammonium nitrogen (931–1,508.9 mg N-NH4 +/dm3), phosphates (24.3–89.4 mg PO4 3–/dm3) and organic compounds referred to as COD (784–1,856 mg O2/dm3). It was found that the combined effect of inorganic coagulant PIX 123 and polyelectrolyte allowed the reduction of suspended solids and COD in sludge liquids. In the case of suspension, the highest reduction (53.8%) was obtained when using PIX 123. With regard to the changes of COD, similar effects were obtained for PIX 123 (43%) and the combined method (41.6%). The use of the PIX 113 coagulant and Zetag 8160 polyelectrolyte increased the ratio of total suspended solids in the sludge liquids in relation to crude sludge liquids. The PIX 113 coagulant led to reducing the values of COD (90%), ammonium nitrogen (14.9%) and phosphates (93.8%) with relation to crude sludge liquids. Zetag 8160 alone proved to be the least effective.
akość cieczy osadowych powstających w procesach mechanicznego odwadniania osadów zależy od technologii stabilizacji oraz rodzaju urządzenia, prawidłowej jego pracy oraz właściwego doboru środków chemicznych do kondycjonowania. W artykule przedstawiono wpływ wybranych środków i metod kondycjonowania, takich jak: PIX 113, PIX 123, polielektrolit Zetag 8160, pole ultradźwiękowe oraz łączne ich działanie na właściwości cieczy osadowych. Surowe ciecze osadowe charakteryzowały się wysokimi stężeniami azotu amonowego (931,5–1508,9 mg N-NH4 +/dm3), fosforanów (24,3–89,4 mg PO4 3–/dm3) oraz związków organicznych oznaczonych jako ChZT (784,0–1856 mg O2/dm3). Stwierdzono, że połączone działanie nieorganicznego koagulantu PIX 123 i polielektrolitu pozwoliło na zmniejszenie ilości zawiesin oraz ChZT w cieczach osadowych. W przypadku zawiesiny najlepszy stopień jej zmniejszenia uzyskano przy stosowaniu PIX-u 123. Wynosił on 53,8%. Analizując zmiany ChZT, podobne efekty uzyskano dla PIX-u 123 (43%) oraz metody łączonej (41,6%). Natomiast użycie koagulantu PIX 113 i polielektrolitu Zetag 8160 spowodowało w cieczy osadowej zwiększenie zawiesin ogólnych w odniesieniu do surowych cieczy osadowych. Działanie koagulantu PIX 113 wpłynęło na zmniejszenie wartości ChZT (90%), azotu amonowego (14,9%) i fosforanów (93,8%) w odniesieniu do surowych cieczy osadowych. Najmniej skuteczny okazał się polielektrolit Zetag 8160.
Źródło:
Ecological Chemistry and Engineering. A; 2017, 24, 1; 65-74
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dewatering of sludge from electroplating wastewater treatment
Odwadnialność osadów pochodzących z oczyszczania ścieków galwanicznych
Autorzy:
Płonka, I.
Pieczykolan, B.
Kosel, M.
Powiązania:
https://bibliotekanauki.pl/articles/126074.pdf
Data publikacji:
2015
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
sludge from industrial
mechanical dewatering
choice of polyelectrolyte
osady ściekowe z przemysłu
odwadnianie mechaniczne
dobór polielektrolitu
Opis:
Electroplating coating of products more sustainable coatings is their protection or decoration. As a result of these technological processes generated waste water, which are treatment. During the treatment of waste water produced sludge that were the subject of research. Sludge were from wastewater treatment plants located at the manufacturing plant which produces car parts. They were taken from the sludge tank, preceded by sedimentation in the lamella. In order to determine their sensitivity to dewatering the first step was selected the type and dose of reagent. In the second stage of the study conditioned sludge were tested mechanical dewatering centrifuge and belt press simulator. The results obtained showed that the most effective effect was observed when using anionic polyelectrolytes Praestol 2505 and Superfloc A 110 and A 130. Were used in a dose of 2.1 mg/g TS to 3.4 mg/g TS, and from 8.2 mg/g TS to 15.4 mg/g TS. The use of too low a dose of reagent and overdose resulted in unsatisfactory conditioning effects. The excess polyelectrolyte increased viscosity of the liquid sludge, which gave slower water contained therein. Conditioned selected polyelectrolytes sludge were subjected to a mechanical dewatering. The sludge obtained after centrifugation is characterized by a total solids a maximum of 12.7%. The centrifugation process efficiency was influenced by the spin speed and the duration of the process. The best results were obtained for a duration of 10 min and a speed of 3000 turns/min. A higher degree of dewatering of 29.5% TS obtained using the simulator of belt press.
Galwaniczne pokrywanie wyrobów trwalszymi powłokami stanowi ich ochronę lub dekorację. W wyniku tych procesów powstają ścieki technologiczne, które są oczyszczane. Podczas oczyszczania ścieków powstają osady, które stanowiły przedmiot badań. Osady pochodziły z oczyszczalni ścieków znajdującej się przy zakładzie produkującym części samochodowe. Zostały pobrane ze zbiornika szlamowego, poprzedzonego sedymentacją w osadniku lamelowym. W celu określenia ich podatności na odwadnianie w pierwszym etapie dokonano doboru rodzaju i dawki polieletrolitu. W drugim etapie badań kondycjonowane osady poddano próbom mechanicznego odwadniania w wirówce oraz symulatorze prasy taśmowej. Uzyskane wyniki badań wykazały, że najskuteczniejszy wpływ zaobserwowano w przypadku zastosowania polielektrolitów anionowych Praestol 2505 oraz Superfloc A 110 i A 130. W badaniach zastosowano dawki od 2,1 do 3,4 mg/g s.m. oraz od 8,2 do 15,4 mg/g s.m. Zastosowanie zarówno zbyt małej dawki reagenta, jak i przedawkowanie doprowadziło do uzyskania niezadowalających efektów kondycjonowania. Nadmiar polielektrolitu zwiększył lepkość cieczy osadowej, przez co osad wolniej oddawał zawartą w nim wodę. Kondycjonowane wybranymi polielektrolitami osady zostały poddane procesowi mechanicznego odwadniania. W wyniku wirowania otrzymano osad charakteryzujący się zawartością suchej masy maksymalnie 12,7%. Na efektywność procesu odwirowania miała wpływ prędkość wirowania oraz czas trwania procesu. Najlepsze efekty uzyskano dla czasu wynoszącego 10 min oraz prędkości 3000 obr/min. Wyższy stopień odwodnienia wynoszący 29,5% s.m. uzyskano przy zastosowaniu symulatora pracy taśmowej.
Źródło:
Proceedings of ECOpole; 2015, 9, 1; 125-132
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies