Tytuł:
Scenarios to reduce evaporation from class A evaporation pan by using windbreaks
Autorzy:
Oribi, Mustafa O.
Abdulkareem, Asraa K.
Powiązania:
https://bibliotekanauki.pl/articles/118708.pdf
Data publikacji:
2020
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
evaporation basin
windbreaks natural
open water bodies
wind speed
Opis:
Evaporation from reservoirs and lakes is an important processes frequently occurring in dry, hot regions such as Iraq. In order to preserve the environment and to reduce the amount of evaporation from open water bodies in this study, simulation was performed to reduce evaporation from evaporation basin class A by using windbreaks natural (Conocarpus trees). Three basic scenarios were made that depended on the values of the atmospheric elements affecting the evaporation process in summer according to the modified Penman equation for the conditions of Iraq, the climate factors are temperature, solar radiation, wind speed, dew point, and the effect of the number of windbreaks and their height was also introduced in sub- scenario. Experiments have shown that the best sub-scenario for all basic scenarios is when the windbreaks are placed in a direct direction to the wind blowing on the evaporation basin in the form of three rows, each row contains three trees where the windbreaks are in case cross and the height of the trees is 100 cm and the distance between each tree and another, and between each row and row 15 × 15 cm, the results of this subscenario recorded the highest rate of evaporation reduction up to 35% of its original value before using windbreaks.
Źródło:
Scientific Review Engineering and Environmental Sciences; 2020, 29, 3; 343-354
1732-9353
Pojawia się w:
Scientific Review Engineering and Environmental Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Natural vibrations of a tower structure in mass-changing conditions due to the icing
Drgania własne konstrukcji wieżowej w warunkach zmieniającej się masy układu wskutek oblodzenia
Autorzy:
Kowalski, W.
Swierczek, E.
Powiązania:
https://bibliotekanauki.pl/articles/40218.pdf
Data publikacji:
2016
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
natural vibration
tower structure
tower model
mass-changing condition
icing
transmission tower
wind-induced resonance
Opis:
The study analyzed the impact of additional tower structure masses on the change of the frequency of its natural vibrations; it also made attempts to mathematical description of this impact. Considerations apply to the tower supporting the lighting system of the city stadium in Ostrowiec Świętokrzyski. The source of additional masses is the icing (frost, rime) and non-structural components constituting the technical equipment of the tower. The analysis was made by modeling by means of the Finite Element Method (FEM) of the structure with the assumption of a one parameter variation of its mass (i.e., the additional mass of all components, structural and non-structural, changes in proportion to one parameter, which is the outer surface of the element on which the ice layer is deposited). Solving the problem of natural vibrations, for subsequent models, representing different intensity of tower's icing, the following natural frequencies have been established. Thus, the increase of the ice-layer thickness on the surfaces from 0 to 2.4 cm caused the reduction of basic natural frequencies by a value, consecutively: for f1 → 26.9%; for f → 27.2%. These values are important from the point of view of technical applications. The findings allow to formulate a postulate that, in the analysis of tower's structure susceptibility to gusts of wind, structure's mass variability resulting from its possible icing was taken into consideration.
W pracy dokonano analizy wpływu dodatkowych mas konstrukcji wieżowej na zmianę częstotliwości jej drgań własnych; dokonano też próby matematycznego opisu tego wpływu. Rozważania dotyczą wieży wsporczej oświetlenia stadionu miejskiego w Ostrowcu Świętokrzyskim. Źródłem dodatkowych mas jest oblodzenie (szron, szadź) oraz elementy niekonstrukcyjne stanowiące wyposażenie techniczne wieży. Analizy dokonano w drodze modelowania metodą elementów skończonych (MES) konstrukcji, przyjmując założenie o jednoparametrycznej zmienności jej masy (to znaczy, że dodatkowa masa wszystkich elementów, konstrukcyjnych i niekonstrukcyjnych zmienia się proporcjonalnie do jednego parametru, którym jest powierzchnia zewnętrzna elementu, na której odkłada się warstwa lodu). Rozwiązując zagadnienie własne drgań dla kolejnych modeli, reprezentujących różne intensywności oblodzenia wieży, wyznaczono wartości kolejnych częstotliwości drgań własnych. I tak, przyrost grubości warstwy lodu na powierzchniach, od 0 do 2,4 cm spowodował redukcję podstawowych częstotliwości drgań własnych o wartości kolejno: dla f1 → 26,9%; dla f2 → 27,2%. Są to istotne wartości z punktu widzenia zastosowań technicznych. Uzyskane wyniki pozwalają na sformułowanie postulatu, aby w analizach podatności konstrukcji wieżowych na porywy wiatru uwzględniana była zmienność masy konstrukcji wynikająca z możliwego jej oblodzenia.
Źródło:
Acta Scientiarum Polonorum. Architectura; 2016, 15, 2
1644-0633
Pojawia się w:
Acta Scientiarum Polonorum. Architectura
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies