Tytuł:
Measurements of nanohardness and elasticity modulus of titanium after magnetoelectropolishing
Pomiary nanotwardości i modułu sprężystości tytanu po magnetoelektropolerowaniu
Autorzy:
Hryniewicz, T.
Rokosz, K.
Valicek, J.
Rokicki, R.
Harnicarova, M.
Vylezik, M.
Powiązania:
https://bibliotekanauki.pl/articles/153005.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
nanoindentation
titanium biomaterials
nanohardness
Young's modulus
magnetoelectropolishing (MEP)
nanoindentacja
tytan
magnetoelektropolerowanie (MEP)
nanotwardość
moduł Younga
Opis:
Nanohardness is one of the main mechanical properties of the studied metal surface after electropolishing operations. The nanoindentation measurements were performed on CP-titanium biomaterial after its treatment under a standard electropolishing (EP) and magnetoelectro-polishing (MEP) conditions, with abrasive polishing (MP) performed on the samples for reference. In the studies, both the Young’s modulus of elasticity and nanohardness were investigated. It was found that the mechanical properties of titanium biomaterial indicated an evident dependence on the type and conditions of surface treatment. After magnetoelectropolishing (MEP) operation a considerable change in mechanical properties of the same Ti biomaterial was observed. One may state that the mechanical properties obtained on the titanium samples both after abrasive polishing (MP) and after a standard electropolishing (EP) are very different from those gained on the magnetoelectropolished titanium sample.
Nanotwardość jest jedną z ważniejszych cech mechanicznych powierzchni metali po obróbce elektropolerowaniem. W tradycyjnych badaniach twardości materiału, diamentowa końcówka wgłębnika służy badaniu twardości i modułu sprężystości. Pod obciążeniem wgłębnika następują odkształcenia sprężyste i plastyczne. Dobór wielkości obciążenia uzależniony jest od celu badania – samego materiału, czy też warstewek pasywnych powstałych na powierzchni metalu po określonej obróbce wykończającej. W artykule przedstawiono wyniki pomiarów metodą nanoindentacji próbek tytanu o czystości komercyjnej po polerowaniu elektrolitycznym w warunkach standardowych (EP), i magnetoelektro-polerowaniu (MEP), oraz po polerowaniu ściernym (MP) próbek, które posłużyły jako odniesienie. Badano moduł sprężystości Younga oraz nanotwardość materiału. Wyniki badań pokazują, że własności mechaniczne tytanu zależą od rodzaju i warunków obróbki wykończającej. Po magnetoelektropolerowaniu (MEP) wyniki nanoindentacji różnią się zasadniczo od analogicznych wyników uzyskanych po standardowym elektropolerowaniu (EP) i po polerowaniu ściernym (MP). Taka zmiana zasadniczo wpływa na poprawę odporności na przeginanie, zginanie i skręcanie biomateriału.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 7, 7; 676-679
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of the effect of forging temperature on the microstructure of grade 5 titanium ELI
Autorzy:
Dziubińska, A.
Majerski, K.
Winiarski, G.
Powiązania:
https://bibliotekanauki.pl/articles/102101.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
grade 5 titanium ELI
biomaterials
metal forming
forging
microstructure
hardness
Opis:
The paper reports the experimental results of an investigation of the effect of forging temperature on the microstructure and hardness of Grade 5 titanium ELI. A growing interest in the use of titanium alloys in implantology results from their unique properties. Grade 5 titanium ELI is widely used in medicine for producing a variety of implants and medical tools such as hip, knee and shoulder joints; bone plates; pacemaker casing and its components; screws; nails; dental materials and tools. In the first part of the paper the properties of Grade 5 titanium ELI are described and examples of medical applications of this alloy are given. In a subsequent section of the paper, forging tests performed on this biomaterial in a temperature range from 750°C to 1100°C are described. Following the forging process, the results of the titanium alloy’s microstructure and hardness are reported. The experimental results are used to determine the most suitable forging temperature range for Grade 5 titanium ELI with respect to its microstructure.
Źródło:
Advances in Science and Technology. Research Journal; 2017, 11, 4; 147-158
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of the Mechanical and Antibacterial Properties of Surface Modified Steel for Medical Applications
Badanie właściwości mechanicznych i antybakteryjnych modyfikowanej powierzchniowo stali do zastosowań medycznych
Autorzy:
Taratuta, Anna
Lisoń-Kubica, Julia
Kazek-Kęsik, Alicja
Antonowicz, Magdalena
Basiaga, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/27310189.pdf
Data publikacji:
2023
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
titanium nitride
stainless steel
biomaterials
antibacterial properties
PVD
azotek tytanu
stal nierdzewna
biomateriały
własności antybakteryjne
Opis:
Various types of metal implants, both in Poland and worldwide, are mainly manufactured from stainless steel due to their biocompatibility, strength, and relatively low price. However, any such procedure involves the risk of peri-implant infection, stimulated, among other things, by the formation of a bacterial biofilm on the surface of the implant. In this paper, several methods of modifying the surface of steel for medical applications were proposed, such as mechanical polishing, electropolishing, sandblasting, and the application of a thin surface layer. This was followed by a series of physicochemical and biological tests. The results indicate that the titanium nitride coating improved corrosion resistance and reduced bacterial adhesion on the surface. No significant improvement in abrasion was observed, and the adhesion of the coating closely depended on the method of preparation.
Implanty metalowe, zarówno w Polsce, jak i na świecie, produkowane są głównie ze stali nierdzewnej ze względu na jej biokompatybilność, wytrzymałość i stosunkowo niską cenę. Jednak każdy tego rodzaju zabieg wiąże się z ryzykiem powstania zakażenia okołowszczepowego, stymulowanego m.in. powstawaniem biofilmu bakteryjnego na powierzchni implantu. W pracy zaproponowano kilka metod modyfikacji powierzchni stali do zastosowań medycznych, takich jak polerowanie mechaniczne, elektropolerowanie, piaskowanie oraz nałożenie cienkiej warstwy powierzchniowej. Następnie przeprowadzono szereg badań fizykochemicznych i biologicznych. Wyniki wskazują, że powłoka azotku tytanu poprawiła odporność na korozję oraz ograniczyła adhezję bakterii na powierzchni. Nie zaobserwowano znaczącej poprawy ścieralności, a adhezja powłoki ściśle zależała od metody jej przygotowania.
Źródło:
Tribologia; 2023, 2; 85--95
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie odporności na zużycie ścierne wybranych biomateriałów metalicznych przeznaczonych na komponenty endoprotez ortopedycznych
Comparison of the abrasion resistance of the selected biomaterials for friction components in orthopedic endoprostheses
Autorzy:
Zasińska, K.
Seramak, T.
Łubiński, J. I.
Powiązania:
https://bibliotekanauki.pl/articles/189022.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
zużycie ścierne
biomateriały
endoprotezy
stopy tytanu
staw biodrowy
abrasive wear
biomaterials
endoprosthesis
titanium alloys
hip joint
Opis:
Rosnące z każdym rokiem zapotrzebowanie na endoprotezy stawów ortopedycznych przy jednoczesnym dążeniu do zwiększenia ich trwałości i wyeliminowania negatywnych skutków ubocznych produktów zużycia, które mogą wywoływać proces zapalny w tkankach determinuje potrzebę poszukiwania nowych biomateriałów bądź metody modyfikacji ich powierzchni. Nadrzędnym celem prowadzonych przez nas badań było oszacowanie intensywności zużycia ściernego biomateriałów obecnie stosowanych na pary trące w endoprotezach ortopedycznych oraz nowego stopu tytanu Ti13Nb13Zr w aspekcie zastosowania go na elementy trące endoprotez. Do badań użyto czterech biomateriałów metalicznych: stopu Ti13Nb13Zr, stali nierdzewnej 316 LVM, stopu CoCrMo oraz stopu Ti6Al4V. Materiałem przeciwpróbki był polietylen o ultrawysokiej masie cząsteczkowej (PE-UHMW). Oceny odporności na zużycie ścierne badanych biomateriałów dokonano na podstawie wyznaczania wartości współczynnika tarcia dla konkretnej pary trącej, zmierzenia profili chropowatości powierzchni oraz obserwacji mikroskopowych (LM).
The demand for orthopaedic joint prosthesis is growing each year. Simultaneously striving to increase their durability and eliminate negative effects of wear products that can cause inflammation in the tissues determines the need to search for new biomaterials or methods for the modification their surfaces. The overall objective of our research was to estimate the intensity of abrasive wear in currently used biomaterials on the friction pairs in orthopaedic endoprosthesis and the intensity of abrasive wear of a new titanium alloy (Ti13Nb13Zr) in the aspect of its practical use on the friction pairs in orthopaedic prostheses. For the research purposes, the following four metallic biomaterials were used: Ti13Nb13Zr alloy, 316 LVM stainless steel, CoCrMo alloy, and Ti6Al4V alloy. The counter samples in each of the friction pairs were made from ultra-high molecular weight polyethylene (PE-UHMW). It is important to tribological tests on the samples of friction pairs and then on the elements of endoprostheses. Evaluation of the abrasive wear resistance of the tested biomaterials was based on the determination of the friction coefficient for the particular friction pair and the measurement of the profiles of the surface roughness and optical microscopy observations by means of a light microscopy (LM). The analysis of the research results shows that the Ti13Nb13Zr alloy has relatively good tribological properties and allows for obtaining a low frictional resistance in the friction pair with PE-UHMW. Furthermore, considering the favourable mechanical properties of the tested Ti13Nb13Zr alloy and its high biocompatibility with the human body, it seems to be the very perspective biomaterial for use for the longterm implants. The desire to improve its durability in the researched biotribological system leads to searching for methods for the modification its surface.
Źródło:
Tribologia; 2015, 6; 187-198
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena zużycia ściernego stopu Ti13Nb13Zr implantowanego jonami azotu, przeznaczonego na elementy trące w endoprotezach ortopedycznych
The evaluation of the abrasive wear of the Ti13Nb13Zr alloy implanted by nitrogen ions for friction components of the hip joint endoprostheses
Autorzy:
Zasińska, K.
Piątkowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/188276.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
implantacja jonowa
stop tytanu
zużycie ścierne
azot
staw biodrowy
biomateriały
ion implantation
titanium alloy
abrasive wear
nitrogen
hip joint
biomaterials
Opis:
Z uwagi na potrzeby społeczne, a zwłaszcza rosnące zapotrzebowanie na endoprotezy stawów biodrowego i kolanowego oraz uwzględniając fakt, że procesy tribologiczne odgrywają wiodącą rolę w procesie utraty stabilności endoprotez ortopedycznych i decydują o ich trwałości, uznano za celowe przeprowadzenie oceny wpływu implantacji jonowej na zużycie ścierne biostopu Ti13Nb13Zr. Do badań wykorzystano pary trące: nieimplantowany stop Ti13Nb13Zr/PEUHMW oraz implantowany jonami N+ stop Ti13Nb13Zr/PE-UHMW. Autorzy zastosowali implantację jonów N+ do stopu Ti13Nb13Zr w celu poprawy jego własności tribologicznych. Testy tribologiczne badanej pary trącej przeprowadzono z wykorzystaniem tribometru PT-3. W artykule przedstawiono wyniki badań chropowatości i falistości powierzchni badanych biomateriałów oraz ich obserwacje z wykorzystaniem mikroskopu świetlnego (LM). Określono również wpływ implantacji jonowej badanego stopu Ti na intensywność jego zużycia pod kątem jego praktycznego zastosowania na pary trące w endoprotezie stawu biodrowego. Analiza wyników wskazała, że przy zadanych parametrach procesu implantacji jonowej implantowane próbki zużywają się znacznie wolniej niż próbki nieimplantowane.
Due to social needs, and especially the growing demand for the hip and knee prostheses and taking into account the fact that the tribological processes play a leading role in the loss of the stability of orthopaedic prostheses and determines their durability, it was considered to be important to assess the impact of the ion implantation on the abrasive wear of Ti13Nb13Zr bio-alloy. For the study, the following friction pairs were used: not implanted Ti13Nb13Zr alloy/PE-UHMW, and Ti13Nb13Zr alloy/PE-UHMW implanted with N+ ions. For the tribological tests, a Ti13Nb13Zr alloy was selected for several reasons: It contains no potentially toxic elements; it has a Young's modulus that is similar to the modulus of bone, with good mechanical properties and a medical certificate for use. The preliminary tribological tests of the Ti alloy carried out earlier by the authors revealed its low resistance to abrasive wear. Therefore, the authors applied the ion implantation of N+ ions to Ti13Nb13Zr alloy in order to improve its tribological properties. The tribological tests of the friction pairs were carried out by means of a PT-3 tribometer. In the article, the tests results of the roughness and waviness and the observations of friction surfaces of the tested biomaterials carried out by means of the light microscope (LM) were presented. The impact of the ion implantation of the investigated Ti alloy on its wear intensity in the aspect of its practical use on friction pairs in the hip replacement was also determined. The result analysis indicated that, for the assumed parameters of the ion implantation process, the implanted samples wear out much more slowly than the non-implanted samples.
Źródło:
Tribologia; 2015, 6; 175-186
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of Tribological Properties of Ti13Nb13Zr Titanium Alloy Used in Medicine
Ocena właściwości tribologicznych stopu tytanu TI13Nb13Zr stosowanego w medycynie
Autorzy:
Piotrowska, Katarzyna
Madej, Monika
Ozimina, Dariusz
Powiązania:
https://bibliotekanauki.pl/articles/190757.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
biomateriały
stopy tytanu
pomiary powierzchni
struktura geometryczna powierzchni
tarcie
zużycie
staw biodrowy
biomaterials
titanium alloys
surface measurements
surface texture
friction
wear
hip joint
Opis:
Celem niniejszej pracy była ocena zużycia biomateriałów tytanowych stosowanych na elementy endoprotezy stawu biodrowego. Materiałem do badań były próbki z tytanu i jego stopów: Ti grade 4, Ti6Al7Nb i Ti13Nb13Zr. Modelowe badania tribologiczne przeprowadzono w ruchu posuwisto-zwrotnym w warunkach tarcia technicznie suchego, tarcia ze smarowaniem roztworem sztucznej krwi oraz roztworem Ringera. Przeciwpróbką w badanych węzłach tarcia była kulka z Al2O3 o średnicy 6 mm. Za pomocą elektronowej mikroskopii skaningowej obserwowano ślady wytarcia po testach tribologicznych. Mikroskop konfokalny z trybem interferometrycznym posłużył do oceny zużycia powierzchni próbek i przeciwpróbek. Najmniejsze współczynniki tarcia spośród wszystkich badanych skojarzeń materiałowych uzyskano dla skojarzenia materiałowego– stop Ti13Nb13Zr-Al2O3. Analiza SEM wykazała, że w wyniku procesu zużywania generowane były liczne rysy i bruzdy. Powstały one na skutek przemieszczania się luźnych produktów zużycia w obszarze wytarcia. Dla wszystkich badanych materiałów zaobserwowano spiętrzenie obrzeży krawędzi śladów wytarcia świadczące o ściernym mechanizmie zużycia. Podczas testów tarciowych badanych skojarzeń materiałowych najbardziej zużywającym się materiałem była tytanowa tarcza. W przypadku stopów Ti6Al7Nb oraz Ti13Nb13Zr zarejestrowano porównywalne zużycie bez względu na warunki prowadzenia testów (TDF, AB, RS). Analiza otrzymanych wyników badań tribologicznych wykazała, że skojarzeniem, dla którego zarejestrowano najmniejsze zużycie pary trącej (próbki i przeciwpróbki), było skojarzenie materiałowe Ti6Al7Nb-Al2O3.
The aim of this study was to evaluate the wear and tear of titanium biomaterials used for hip endoprosthesis. The test materials were samples of titanium and its alloys: Ti grade 4, Ti6Al7Nb and Ti13Nb13Zr. Model tribological tests were carried out in reciprocal motion under conditions of technically dry friction, friction with lubrication provided by an artificial blood solution and Ringer's solution. A 6 mm in diameter Al2O3 ball was used as a counter-sample in the friction pairs. After tribological tests, traces of wear were inspected using scanning electron microscopy. A confocal microscope with interferometric mode was used to evaluate the wear of the surface of samples and counter-samples. The lowest friction coefficients among all the material associations were obtained for the Ti13Nb13Zr-Al2O3 alloy. SEM analysis has shown that as a result of the wear process, numerous scratches and grooves were generated. They were created as a result of loose products of wear moving around in the friction area. For all tested materials, a pile-up of the wear edges was observed, which indicates an abrasive wear mechanism. During the friction tests of the tested material associations, the titanium disc proved to be the most wearing material. For Ti6Al7Nb and Ti13Nb13Zr alloys, comparable wear was recorded regardless of the test conditions (TDF, AB, RS). The analysis of the obtained tribological results showed that the material association for which the lowest wear of friction pair (sample and countersample) recorded was Ti6Al7Nb-Al2O3.
Źródło:
Tribologia; 2019, 285, 3; 97-106
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies