Assessment of the impact of probe head hysteresis on the accuracy of five-axis coordinate measuring systems
Autorzy:
Gąska, P.
Gruza, M.
Gąska, A.
Harmatys, W.
Sładek, J.
Powiązania:
https://bibliotekanauki.pl/articles/102633.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
articulating probe head
hysteresis
accuracy
CMM
Opis:
One of the factors affecting the accuracy of Coordinate Measuring Systems is hysteresis of a probe head. It is important especially in case of touch trigger probes and should be taken into account during the determination of probing strategy. In this article, the authors try to assess how this phenomenon affects the accuracy of five axis coordinate systems which utilize articulating probe head. Such systems allow to measure point coordinates using rotary movements of the head what introduces changes to the probing process. The experiments presented in this paper are based on multiple measurements of the reference elements such as gauge blocks and standard ring.
Źródło:
Advances in Science and Technology. Research Journal; 2017, 11, 3; 277-282
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problemy związane z korekcją promienia końcówki pomiarowej podczas skaningowych pomiarów współrzędnościowych
Difficulties with the corrected measured point determination in coordinate metrology
Autorzy:
Woźniak, A.
Mayer, M.
Cote, M.
Powiązania:
https://bibliotekanauki.pl/articles/153572.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
Współrzędnościowa Maszyna Pomiarowa
WMP
sonda głowica skaningowa
korekcja promienia końcówki
Coordinate Measuring Machine
CMM
scanning probe
probe radius compensation
Opis:
W artykule przedstawiono analizy teoretyczne i badania doświadczalne potwierdzające, że korekcja promienia końcówki pomiarowej może być istotnym źródłem błędów podczas saningowych pomiarów przeprowadzanych na maszynach współrzędnościowych. Przedstawiono wyniki pomiarów przykładowego elementu na maszynie Mitutoyo LEGEX 910 CMM wyposażonej w sondę skaningową MPP-300, ze wskazaniem mechanizmów złej korekcji promienia końcówki pomiarowej.
Paper discusses an understanding for the compensation of the probe ball radius in a scanning process carried out by coordinate measuring machines (CMM). According to some initial trials of scanning measurement using the stylus tip radius correction built-in the CMM software, it was found, as will be shown in the paper, that the indigenous CMM software do not compensate the stylus tip radius well. As a result, the information about the real shape of the measured reatures can be distored. The difficulties with the corrected measured point determination will be demonstrate no the basis of tests were carried out on a Mitutoyo LEGEX 910 CMM equipped with a MPP-300 scanning probe.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9 bis, 9 bis; 485-488
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of measured workpiece’s form errors influence on the accuracy of probe heads used on five-axis measuring systems
Autorzy:
Harmatys, W.
Gąska, A.
Gruza, M.
Gąska, P.
Sładek, J.
Powiązania:
https://bibliotekanauki.pl/articles/102182.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
articulating probe head
five-axis system
accuracy
CMM
Opis:
The five-axis measuring systems are one of the most modern inventions in coordinate measuring technique. They are capable of performing measurements using only the rotary pairs present in their kinematic structure. This possibility is very useful because it may cause significant reduction of total measurement time and costs. However, it was noted that high values of measured workpiece’s form errors may cause significant reduction of the accuracy of a five-axis measuring system. The investigation on the relation between these two parameters was conducted in this paper and possible reasons of decrease in measurement accuracy was discussed on the example of measurements of workpieces with form errors ranging from 0,5 to 1,7 millimetre.
Źródło:
Advances in Science and Technology. Research Journal; 2017, 11, 4; 305-310
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement uncertainty analysis of different CNC machine tools measurement systems
Autorzy:
Semotiuk, L.
Józwik, J.
Kuric, I.
Powiązania:
https://bibliotekanauki.pl/articles/102390.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
measurement uncertainty
inspection probe
control system
CNC machine tool
Opis:
In this paper the results of measurement uncertainty tests conducted with a Heidenhain TS 649 probe on CNC machine tools are presented. In addition, identification and analysis of random and systematic errors of measurement were presented. Analyses were performed on the basis of measurements taken on two different CNC machine tools with Heidenhain control system. The evaluated errors were discussed and compensation procedures were proposed. The obtained results were described in tables and figures.
Źródło:
Advances in Science and Technology. Research Journal; 2013, 7, 19; 41-47
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Concept of a Collection System for Gas Mixture from the Interior of Chimney Openings for Unmanned Flying Systems
Autorzy:
Klimczyk, Michał
Powiązania:
https://bibliotekanauki.pl/articles/2123293.pdf
Data publikacji:
2021
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
drone
UAV
air pollution
quality
environment
smog
probe
chimney
Opis:
Today, one of the most topical issues related to the quality and safety of life on Earth is the monitoring of air quality in terms of its pollution that is harmful to human health and life. The activities undertaken as part of monitoring carried out include, among others, analysis of the composition of exhaust fumes from emission sources, such as households and industrial entities, in terms of the presence therein of potentially hazardous substances, indirectly in order to detect violations of the applicable environmental standards. In order to conduct this type of analysis, unmanned aerial systems are commonly used, which allow sampling in the immediate vicinity of the emission source. However, the currently functioning solutions do not allow for exhaust fume sampling in a way that allows a mixture for testing to be taken directly from an emission source. This leads to questioning of the reliability of the conducted research, as it is uncertain in terms of the origin of the tested mixture, indicating that the test takes place not at the source of the emission, but in its surroundings. This study proposes a technical solution to sample exhaust fumes directly from the emission source - from the interior of chimney openings.
Źródło:
Advances in Science and Technology. Research Journal; 2021, 15, 3; 191--196
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Częstotliwościowa metoda pomiaru zespolonej przenikalności dielektrycznej materiałów porowatych przy zastosowaniu sond o różnej długości
Frequency method for the measurement of the porous materials complex dielectric permittivity using probes of different length
Autorzy:
Wilczek, A.
Skierucha, W.
Powiązania:
https://bibliotekanauki.pl/articles/156814.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
właściwości gleby
zespolona przenikalność dielektryczna
sonda Open-Ended
sonda dwuprętowa
soil properties
complex dielectric permittivity
Open-Ended probe
two-rod probe
Opis:
Celem pracy jest porównanie dwóch metod pomiaru zespolonej przenikalności dielektrycznej gleby. W pierwszej metodzie wykorzystywanej do pomiarów referencyjnych użyta została sonda Open-Ended. W drugiej metodzie do pomiarów zostały wykorzystane sondy dwuprętowe o różnej długości, przy pomocy których dokonywano pomiaru przenikalności dielektrycznej w tak dobranych częstotliwościach, aby można je było traktować jako elementy o parametrach skupionych. W pracy przedstawiono kalibrację sond dwuprętowych metodą używaną do kalibracji sond Open-Ended. Polega ona na pomiarach sond w stanach zwarcia, rozwarcia i po umieszczeniu ich w ośrodku o znanych właściwościach dielektrycznych. Po kalibracji dokonano pomiarów parametrów odbiciowych na próbkach trzech gleb w wybranych częstotliwościach. Wszystkie pomiary wykonywane były wektorowym analizatorem sieci pracującym w zakresie częstotliwości 20 kHz + 8 GHz. Obiektami badanymi były trzy gleby o różnym rozkładzie granulometrycznym oraz wilgotności. Ze względu na specyfikę pomiaru w pracy przedstawiono analizę dla jednej tylko gleby. Porównanie wyników pozwala sądzić, że stosowane metody wykazują się wysoką korelacją wyników w przypadku pomiarów obu składowych zespolonej przenikalności dielektrycznej.
The main aim of the study is comparision of two measurement methods of the complex dielectric permittivity of soils. The first one used an Open-Ended probe and it was a reference method. The other one used two-rod probes of different length. These probes measured reflection parameters soils in selected frequencies that enabled to treat the probes as elements of lumped parameters. The study presents calibration of the two-rod probes using the method applied in Open-Ended probes. Il consists of measurements in shorted and open states as well as the measurement in a medium of known dielectric properties. All measurements were done using a vector network analyzer of the frequency range 20 kHz 8 GHz. Three soils of various texture and moisture were the analysed objects. Due to specificity of the measurement the paper presents the analysis for only one soil. The comparison of the measured data shows that the real and imaginary parts of the complex dielectric permittivity measured by both methods are highly correlated.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9 bis, 9 bis; 680-682
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of the influence of calibration sphere parameters on the results of articulating probe head qualification
Autorzy:
Gruza, Maciej
Gąska, Adam
Gąska, Piotr
Harmatys, Wiktor
Sładek, Jerzy
Powiązania:
https://bibliotekanauki.pl/articles/103260.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
articulating probe head
calibration
accuracy
przegubowa głowica sondy
kalibrowanie
precyzja
Opis:
The qualification of probe heads before the measurements performed with their usage is now a standard procedure. It is used for correction of probe head’s and measuring tip systematic errors. The calibration sphere, which is used for this process, should have adequately small form errors. However, it is not always possible to use a highly accurate spheres and it is a common practice to use a sphere that was provided by the manufacturer of the CMM for a long time. This is why, the authors have tried to answer the question about the impact of the calibration sphere inaccuracies on the results of probe head qualification process.
Źródło:
Advances in Science and Technology. Research Journal; 2018, 12, 2; 252-259
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Model kinetyczny przetwornika pasywnych głowic skaningowych CMM
Kinetic model of CMM scanning passive probe transducer
Autorzy:
Krajewski, G.
Woźniak, A.
Powiązania:
https://bibliotekanauki.pl/articles/155447.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
głowica skanująca
współrzędnościowa maszyna pomiarowa
CMM
scanning probe
coordinate measuring machine
Opis:
W artykule przedstawiono analizę teoretyczną budowy przetwornika głowic skaningowych pasywnych stosowanych do pomiarów w technice współrzędnościowej. W efekcie podjętych prac autorzy otrzymali wstępny model dynamiczny pracy głowic, który może posłużć do kompensacji ich błędów powstałych na skutek zwiększenia prędkości pomiarowej.
Scanning probes, also known as measuring probes, are one of the most often used equipment of coordinate measuring machines (CMM) owing to ability of collecting large number of measuring points as well as taking fast measurements. High speed of measurements and high accuracy of the measuring system are two critical parameters deciding about the machine effectiveness. Dynamics is the most significant factor limiting the measurement accuracy. In most investigations of scanning CMM there is not separated the probing system performance from other sources of the machine errors, so the true error influenced by the probing system is not profoundly determined. This paper presents the scanning probe model regardless of the machine links. The worked out model allows for better understanding of the probing process with higher speed and optimising the measuring process. The future works will aim at proposing optimisation algorithms and applying them to the probing system as well as obtaining improvement in the accuracy.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 1, 1; 50-51
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowa metoda generowania punktów offsetowych po skanowaniu CMM
The new method of generation of offset points after CMM scanning
Autorzy:
Filipowski, R.
Dąbrowski, L.
Zawora, J.
Powiązania:
https://bibliotekanauki.pl/articles/157835.pdf
Data publikacji:
2005
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
głowica pomiarowa
interpolacja
parametryzacja krzywej
probe head
interpolation
form of curve
Opis:
Skanowanie złożonych powierzchni na współrzędnościowej maszynie pomiarowej (CMM) jest szybką metodą ich pomiaru. Współrzędne punktów środka kulki głowicy pomiarowej w układzie współrzędnych kartezjańskich są zapisywane do zbioru danych w komputerze (PC). Każdy punkt pomiarowy jest określony przez wektor pozycyjny w prostokątnym układzie oraz parametr zmieniający się od zera do jedności. Przez punkty pomiarowe prowadzi się krzywe parametryczne Fergusona (splajn) a następnie przy ich pomocy generuje się punkty offsetowe. Zastosowane interpolacyjne funkcje Fergusona pozwalają uzyskać dobrą dokładność obliczenia położenia punktów offsetowych powierzchni mierzonych.
This paper presents a new method generating offset points after scanning process of cylindrical surface on the CMM, were in to the file of the connected PC using part coordinate system. The cartesian coordinates of points are transformed in parameter coordinates. By the processing of scanning data, the distance between points are made nearly equal. That way some points positioned too closely were eliminated form the calculation process. This closeness was caused by variation in CMM scanning speed. In the last step, the processed points with parameter coordinates were connected to the Ferguson function, thus enabling determining the position of the offset points. The parameter coordinates of points and the third degree curve (Ferguson curve) lead to very good accuracy of reverse engineering process for cylindrical surfaces.
Źródło:
Pomiary Automatyka Kontrola; 2005, R. 51, nr 11, 11; 5-8
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelowanie błędów głowicy pomiarowej z zastosowaniem metody Monte Carlo
Modeling of probing system errors by use of Monte Carlo method
Autorzy:
Sładek, J.
Juras, B.,
Krawczyk, M.
Gąska, A.
Powiązania:
https://bibliotekanauki.pl/articles/152502.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
głowica pomiarowa
niepewność
metoda Monte Carlo
probe head
uncertainty
Monte Carlo
Opis:
W obecnych czasach, gdy nowoczesne techniki wytwarzania umożliwiają produkcję części z coraz to większą dokładnością, a tolerancje ich wykonania stają się coraz węższe, pojawia się potrzeba bardzo dokładnego wyznaczania niepewności pomiarów. Ważne jest również, aby proces estymacji niepewności stawał się jak najszybszy. Z tego powodu najlepiej rozwinięte laboratoria metrologiczne starają się stworzyć wirtualne modele WMP, które są w stanie wyznaczyć niepewność pomiarów w czasie quasi-rzeczywistym. Ten artykuł przedstawia sposób modelowania błędów głowicy pomiarowej z wykorzystaniem metody Monte Carlo. Błędy głowicy pomiarowej stanowią znaczną część całkowitych błędów maszyny pomiarowej, a zaprezentowany model może zostać wykorzystany jako jeden z modułów wirtualnej WMP.
Nowadays, when the manufacturing technologies are getting more and more precise, and the tolerances are getting narrower, there is a need of expressing the uncertainty of measurement at the really high level. It is also important to make the uncertainty estimation as quick as possible. This is why the most developed metrological laboratories are trying to create the virtual CMM models that can handle uncertainty evaluation in quasi-real time. This paper shows how to model, with use of the Monte Carlo method, the probing system errors which are one of the most significant errors of CMMs. The presented model can then be used as a module of virtual CMM. Paragraph 2 presents the theoretical basis of probing system operation. It also points out the factors causing probing system errors. The mentioned model of probe head errors is presented in Paragraph 3. Paragraph 4 gives the results of the measurements and simulations that have been performed to show functionality and correctness of the model. Conclusions and areas of development are presented in Paragraph 5.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 8, 8; 946-949
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of geometric precision of plastic components made by subtractive and additive methods
Autorzy:
Fudali, P.
Witkowski, W.
Wydrzyński, D.
Powiązania:
https://bibliotekanauki.pl/articles/101936.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
rapid prototyping
fused deposition modelling
machining
touch probe measurement
points cloud
Opis:
The paper presents information on manufacturing processes of plastic components. Basic subtractive and additive methods are described. There were also manufactured elements of fan housing by using this two types of methods. Then, the elements were measured using a touch probe. The obtained results were analyzed, on which a comparison of components’ geometric accuracy was performed.
Źródło:
Advances in Science and Technology. Research Journal; 2013, 7, 19; 36-40
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Odkształcenia cieplne a niedokładność pomiaru sondą przedmiotową
Inaccuracy of measurements by inspection probe in relation to thermal deformations
Autorzy:
Jacniacka, E.
Semotiuk, L.
Powiązania:
https://bibliotekanauki.pl/articles/152586.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
sonda przedmiotowa
niepewność pomiaru
odkształcenia cieplne
inspection probe
uncertainty
measurement
thermal deformation
Opis:
Sondy przedmiotowe coraz częściej są standardowym wyposażeniem obrabiarek CNC. Wykorzystywane są do pomiaru wymiarów pomiędzy zabiegami technologicznymi oraz do kontroli po zakończeniu obróbki. W procesach obróbki skrawaniem generowane są znaczne ilości ciepła., które kumulowane w przedmiocie obrabianym, powoduje wzrost jego temperatury i co za tym idzie zmianę wymiarów. W pracy zaprezentowano wyniki pomiaru sondą długości OMP 60 przedmiotów frezowanych wykonanych ze stali C45 i stopu aluminium 2017 A. Przeprowadzony eksperyment pokazał, że odkształcenia wywołane ciepłem generowanym w strefie skrawania są znaczące i nie można ich pominąć podczas pomiaru sondami przedmiotowymi.
Inspection probes are used to measure dimensions between technological operations and to control after completing the machining. Machining generates significant amount of heat which is accumu-lated in a machined object causing change of the object dimensions. In this paper there is discussed the influence of thermal deformation on the accuracy of measurements taken by an inspection probe. In Section 2 there are presented the most important sources of measurement errors and methods for assessment of the measurement accuracy by means of the inspection probe. The study included measurements taken by the inspection probe after machining at given intervals. Two very popular materials, steel C45 and aluminium alloy 2017A, were chosen. In-cut milling with and without cooling with cutting fluid was used as a method of machining. In Fig. 1 the object with marked measurement points is presented. Fig. 2 shows the object fixed in workspace of the machining center. The results of measurements made with use of the inspection probe were compared with those obtained from CMM measurements in 20°C. Elongation ΔL was calculated as a difference between the measurement by the inspection probe OMP 60 and CMM measurement. In Tables 4-7 the average elongation as a function of time from the end of machining to the beginning of measurements is given. Figs. 3 and 4 show its graphic representation.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 9, 9; 985-988
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania porównawcze pomiarów wykonywanych za pomocą współrzędnościowego ramienia pomiarowego wyposażonego w głowicę sztywną i impulsową
Comparative studies of measurements made by a coordinate measuring arm equipped with hard and trigger probes
Autorzy:
Rak, M.
Ratajczyk, E.
Kowaluk, T.
Powiązania:
https://bibliotekanauki.pl/articles/153541.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
współrzędnościowe ramię pomiarowe
głowica (sonda) pomiarowa
coordinate measuring arm (portable CMM)
measuring probe
Opis:
Przedstawiona jest ocena dokładności pomiarów przeprowadzonych głowicą sztywną i przełączającą za pomocą współrzędnościowego ramienia pomiarowego [1]. Ramiona współrzędnościowe są mobilnymi ręcznymi przyrządami pomiarowymi. W celu lokalizacji punktów pomiarowych wyposażone są najczęściej w głowice sztywne. Dzięki użyciu w jednym ramieniu zarówno głowicy sztywnej jak i przełączającej możliwe było porównanie ich ze sobą. Badania eksperymentalne wykonano na podstawie wybranych wymiarów elementu w postaci kostki szkoleniowej. Otrzymane wyniki badań pozwalają ocenić stopień dokładności przy stosowaniu poszczególnych rodzajów głowic.
The purpose of the paper is to assess the accuracy of measurements made with hard and trigger probes on a coordinate measuring arm. In the case of hard heads the measuring force is variable and depends on an operator who decides on appearance of a contact of the stylus tip with the measured surface, while in the case of trigger probes the contact of the tip with the measured surface is independent of shaft swings, breaking the electrical contact inside the head due to deflection of the stylus and breaking the electrical contact inside the head. The study was conducted with use of the arm Metris – Nikon MCA II shown in Fig. 1. Arms are manual measuring devices equipped, in most cases, with hard probes. Through the use of hard and trigger probes in one arm, it is possible to compare two heads. The TP20 kinematic touch-trigger probe with an SF module (standard force) was used as a trigger head. The paper presents a brief description of coordinate measurements as well as construction and working principle of coordinate measuring arms. In Fig. 3 there is shown a CAD model of the training cube used as a test part. The tests were made on the basis of measurements of four cylindrical holes with different diameters. The obtained results for two probes were compared with each other. It was analyzed how the range of results for different diameters for hard and trigger probes changed. The results show the influence of other factors (besides the measuring force). To show the influence of the measuring force, tests on a cube made of different materials were also performed.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 5, 5; 456-458
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Redukowanie czasu obliczeń transformaty Hougha z wykorzystaniem preselekcji implementowane na GPGPU
Reducing the computation time of the Hough Transform implemented on GPGPU using preselection of circles
Autorzy:
Mazurek, P.
Powiązania:
https://bibliotekanauki.pl/articles/155295.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
transformata Hougha
próbnik światła
pomiary oświetlenia
GPGPU
Hough transform
light probe
light measurements
Opis:
W artykule przedstawiono algorytm rzadkiego próbkowania okręgu dla transformaty Hougha, w celu preselekcji okręgów do dalszego przetwarzania. Rozwiązanie pozwala na skrócenie czasu obliczeń, rzędu dwóch razy dla implementacji z wykorzystaniem programowanej karty graficznej (GPGPU). Może ono być zastosowywane do wykrycia jednokolorowej kryzy wokół lustra sferycznego lub półsferycznego służącego do pomiaru oświetlenia. Dzięki temu można analizować obraz wideo zawierający pomiary z różnych obszarów.
The Hough Transform (HT) is a very powerful algorithm for the detection of shapes. It is used for the detection of the flange of a light probe (Fig. 1). GPGPU processing is necessary for HT computation. The proposed algorithm (Fig. 4) is based on the preselection of circles for further computation (Fig. 3). Selection of the circles based on a limited set of pixel samples allows reduction of the processing time up to two times. The reduction is dependent on the image content, but the test shows that the influence of the number of the tested radiuses is less. About one second of the processing time is necessary, so larger images need tens of seconds for computation (Fig. 5). This algorithm uses exhaustive search over all positions and radiuses. One of the interesting applications of the HT is the estimation of the position and diameter of a circle related to the flange of a light probe [2, 3]. Light probes are used for computer graphics applications and they allow application of the real world measurements of light using the Image Based Lighting (IBL) technique. The GPGPU implementation use CUDA based code (CUDA v4.0) [10,11] and 16x8 organization of threads is assumed. The technique proposed for the time and spatial synchronization of the multiple threads for more synchronous read operation from a global memory is applied [7]. The global memory is large and slow, so a GPGPU-global memory interface is the main bottleneck of the system. Synchronization of accesses allows coalescence read operations.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 11, 11; 1171-1173
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Błędy w autokalibracyjnych pomiarach prądu uziemienia przy użyciu cęgów prądowych
The errors of the autocalibration measurement of the grounding current with clamp-on probe
Autorzy:
Wołoszyk, M.
Powiązania:
https://bibliotekanauki.pl/articles/151856.pdf
Data publikacji:
2002
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
autokalibracyjne pomiary prądu uziemienia
cęgi prądowe
autocalibration measurements of the grounding
clamp-on probe
Opis:
We współczesnych miernikach rezystancji uziemienia normą staje się możliwość kontroli wybranego uziemienia pracujacego w systemie uziemień bez odłączania go od tego systemu. Prad płynący przez uziemienie mierzy się w takim przypadku przy użyciu przetwornika cę gowego. Wymagane znaczne rozmiary "okna" cęgów wymuszają stosowanie przetworników o zakresach pomiarowych wielokrotnie większych od wartości mierzonych prądów, co może prowadzić do powstawania nadmiernych błędów pomiarowych. Znaczną poprawę dokładności można uzyskać poprzez zastosowanie pomiarów etapowych, a nastepnie wartość prądu mierzonego wyznacza się na drodze obliczeniowej.
Measurement of earthing impedance (resistance) of complex earthing from the system without disconnecting the tested earthing from the system is getting more and more popular. In that case current transformer. Required large dimensions of the clamp "window" make it necessary to use a transformer of high current range, very exceeding the actual current value. Such situation may result in unaceptable high measurement errors. The accuracy can be improved with autocalibrating technique.
Źródło:
Pomiary Automatyka Kontrola; 2002, R. 48, nr 9, 9; 17-20
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies