Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "modulus young" wg kryterium: Temat


Wyświetlanie 1-13 z 13
Tytuł:
Optimization of process parameters for enhanced mechanical properties of polypropylene ternary nanocomposites
Autorzy:
Ogunleye, O O
Salawudeen, T O
Suleyman, M A
Faridah, Y
Powiązania:
https://bibliotekanauki.pl/articles/102420.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
MWCNT
PPTN
tensile strength
Young's modulus
Opis:
Preparation of Polypropylene ternary nanocomposites (PPTN) was accomplished by blending multiwall carbon nanotube (MWCNT) in polypropylene/clay binary system using a melt intercalation method. The effects of MWCNT loadings (A), melting temperature (B) and mixing speed (C) were investigated and optimized using central composite design. The analysis of the fitted cubic model clearly indicated that A and B were the main factors influencing the tensile properties at a fixed value of C. However, the analysis of variance showed that the interactions between the process parameters, such as; AB, AC, AB2, A2B and ABC, were highly significant on both tensile strength and Young’s modulus enhancement, while no interaction is significant in all models considered for elongation. The established optimal conditions gave 0.17%, 165 °C, and 120 rpm for A, B and C, respectively. These conditions yielded a percentage increase of 57 and 63% for tensile strength and Young’s modulus respectively compared to the virgin Polypropylene used.
Źródło:
Advances in Science and Technology. Research Journal; 2015, 9, 25; 27-33
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of thermal fatigue on young’s modulus of epoxy adhesives
Autorzy:
Kłonica, M.
Powiązania:
https://bibliotekanauki.pl/articles/102676.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
Young's modulus
epoxy adhesive
Hysol 9466
Hysol 3421
thermal shock
Opis:
The following paper presents a comparative analysis of two epoxy-based adhesives: Hysol 9466 and Hysol 3421, prior to and after thermal shock testing. The tests focused on determining Young’s modulus. Epoxy-based materials are among the most widespread adhesive materials used as universal structural adhesives. The prepared epoxy samples (Hysol 9466 and Hysol 3421) were subjected to thermal shock cycling tests, according to a specified programme, in a thermal shock testing chamber, at a temperature range –40 °C to +60 °C and in the number of 200 cycles. Conclusions from the tests are presented at the final stage of the paper.
Źródło:
Advances in Science and Technology. Research Journal; 2015, 9, 28; 103-106
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania porównawcze nanotwardości i zredukowanego modułu Younga wybranych materiałów
Comparative studies of nanohardness and reduced Youngs modulus of the selected materials
Autorzy:
Rokosz, K.
Hryniewicz, T.
Rzadkiewicz, S.
Powiązania:
https://bibliotekanauki.pl/articles/151306.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
nanotwardość
zredukowany moduł Younga
moduł sprężystości
nanoindentacja
nanohardness
reduced Young's modulus
modulus of elasticity
nanoindentation
Opis:
W artykule przedstawiono badania twardości i zredukowanego modułu Younga próbek tytanu Ti i jego stopów Ti-13Nb-13Zr, Ti-24Nb-4Zr-8Sn, niobu Nb i stali nierdzewnej 0H17N14M2. Badania wykonano w VŠB-TU Ostrava (Czechy) nanoindenterem TI 950 TriboIndenter firmy Hysitron. Wyniki przedstawiono w formie wykresów słupkowych oraz w formie tabelarycznej zawierającej przedziały uzyskanych wartości badanych własności mechanicznych materiałów.
The article presents the studies of reduced Young's modulus and hardness of titanium and its alloys, niobium and stainless steel samples, conducted in VŠB-TU Ostrava (Czech Republic) with using nanoindenter Hysitron TI 950 TriboIndenter. The samples by abrasive polishing using Struers Tegra Pol 35 were prepared. Mechanical treatment was carried out by setting the force of 10 N and the rotation speed of 200 min-1, and using abrasive papers successively a grain size of 320, 800, 1000 and 1200 μm. Diamond polishing paste of grain size from 3 to 1 μm to get best surface were used. Measurements showed, that the highest nanohardness revealed niobium (8.11 GPa), the lowest austenitic steel 00H17N14M2 (3.69 GPa). The highest value of reduced Young's modulus was measured for austenitic steel 00H17N14M2 (194.94 GPa), the lowest for titanium alloy Ti-13Nb-13Zr (89.19 GPa). In addition, it was found that the alloy structure and its composition influence the values of the hardness and reduced Young’s modulus.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 10, 10; 917-919
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurements of nanohardness and elasticity modulus of titanium after magnetoelectropolishing
Pomiary nanotwardości i modułu sprężystości tytanu po magnetoelektropolerowaniu
Autorzy:
Hryniewicz, T.
Rokosz, K.
Valicek, J.
Rokicki, R.
Harnicarova, M.
Vylezik, M.
Powiązania:
https://bibliotekanauki.pl/articles/153005.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
nanoindentation
titanium biomaterials
nanohardness
Young's modulus
magnetoelectropolishing (MEP)
nanoindentacja
tytan
magnetoelektropolerowanie (MEP)
nanotwardość
moduł Younga
Opis:
Nanohardness is one of the main mechanical properties of the studied metal surface after electropolishing operations. The nanoindentation measurements were performed on CP-titanium biomaterial after its treatment under a standard electropolishing (EP) and magnetoelectro-polishing (MEP) conditions, with abrasive polishing (MP) performed on the samples for reference. In the studies, both the Young’s modulus of elasticity and nanohardness were investigated. It was found that the mechanical properties of titanium biomaterial indicated an evident dependence on the type and conditions of surface treatment. After magnetoelectropolishing (MEP) operation a considerable change in mechanical properties of the same Ti biomaterial was observed. One may state that the mechanical properties obtained on the titanium samples both after abrasive polishing (MP) and after a standard electropolishing (EP) are very different from those gained on the magnetoelectropolished titanium sample.
Nanotwardość jest jedną z ważniejszych cech mechanicznych powierzchni metali po obróbce elektropolerowaniem. W tradycyjnych badaniach twardości materiału, diamentowa końcówka wgłębnika służy badaniu twardości i modułu sprężystości. Pod obciążeniem wgłębnika następują odkształcenia sprężyste i plastyczne. Dobór wielkości obciążenia uzależniony jest od celu badania – samego materiału, czy też warstewek pasywnych powstałych na powierzchni metalu po określonej obróbce wykończającej. W artykule przedstawiono wyniki pomiarów metodą nanoindentacji próbek tytanu o czystości komercyjnej po polerowaniu elektrolitycznym w warunkach standardowych (EP), i magnetoelektro-polerowaniu (MEP), oraz po polerowaniu ściernym (MP) próbek, które posłużyły jako odniesienie. Badano moduł sprężystości Younga oraz nanotwardość materiału. Wyniki badań pokazują, że własności mechaniczne tytanu zależą od rodzaju i warunków obróbki wykończającej. Po magnetoelektropolerowaniu (MEP) wyniki nanoindentacji różnią się zasadniczo od analogicznych wyników uzyskanych po standardowym elektropolerowaniu (EP) i po polerowaniu ściernym (MP). Taka zmiana zasadniczo wpływa na poprawę odporności na przeginanie, zginanie i skręcanie biomateriału.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 7, 7; 676-679
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Influence of Reducing Temperature on Changing Young’s Modulus and the Coefficient of Friction of Selected Sliding Polymers
Wpływ obniżania temperatury na zmianę modułu Younga oraz współczynnika tarcia wybranych materiałów polimerowych
Autorzy:
Ptak, A.
Kowalewski, P.
Powiązania:
https://bibliotekanauki.pl/articles/188137.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
polymers
Young's modulus
friction coefficient
low temperature
tribology
polimery
moduł Younga
współczynnik tarcia
niska temperatura
tribologia
Opis:
For the polymeric materials, changing of the temperature causes changes in mechanical and tribological properties of sliding pairs. The goal of the present study was to determine the change in Young's modulus and kinetic friction coefficient depending of the temperature. Three thermoplastic polymers, PA6, PET and PEEK, were tested. These materials cooperated in sliding motion with a C45 construction steel disc. As part of the experiment, the Young's modulus tests (by 3-point bending method) and kinetic friction coefficient studies (using pin-on-disc stand) were carried out. The temperature range of mechanical and tribological tests was determined at T = –50°C±20°C. Comparing the results of mechanical and tribological properties, there is a tendency to decrease the coefficient of friction as the Young's modulus increases while reducing the working temperature.
Zmiany temperatury w przypadku materiałów polimerowych są przyczyną zmian własności materiału, a co za tym idzie i właściwości tribologicznych par ślizgowych. Tematem podjętym w niniejszym artykule jest określenie zmiany modułu Younga oraz współczynnika tarcia kinetycznego materiałów polimerowych współpracujących ślizgowo ze stalą w zależności od temperatury. Do badań wykorzystano polimery termoplastyczne: PA6, PET oraz PEEK, które współpracowały ślizgowo ze stalą konstrukcyjną C45. W ramach eksperymentu zostały przeprowadzone badania modułu Younga (3-punktową metodą zginania) oraz badania współczynnika tarcia kinetycznego (wykorzystując stanowisko typu pin-on-disc). Zakres temperatury badań mechanicznych i tribologicznych określony został na poziomie T = –50°C±20°C. Porównując wyniki badań własności mechanicznych z właściwościami tribologicznymi, można zauważyć tendencję do zmniejszenia wartości współczynnika tarcia wraz ze wzrostem modułu Younga podczas obniżania temperatury otoczenia.
Źródło:
Tribologia; 2018, 279, 3; 107-111
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of the effect of the electroless NI-P coating thickness applied on AW-7075 aluminum alloy on its mechanical properties
Autorzy:
Czapczyk, Kazimierz
Siwak, Piotr
Legutko, Stanislaw
Powiązania:
https://bibliotekanauki.pl/articles/957974.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
Ni-P coating
Martens hardness
creep
Young's modulus
aluminium alloy
powłoka Ni-P
pełzanie
Moduł Younga
stop aluminium
Opis:
The paper presents the results of examination of microhardness of chemical coatings Ni-P, applied on samples of aluminium alloy for plastic processing AW-7075. The examinations have been performed on samples with three different thicknesses of the Ni-P coatings; next the influence of their thickness on the depth of material penetration by the indenter under load, as well as its influence on creep, increase of Martens hardness and on the Young’s modulus of the system of the coating with the substrate material. Hardness measurements have been performed with the use of PICODENTOR HM500 nanohardness tester (Vickers). The purpose of the examination of Ni-P coating deformation without dispersion phases is analysis of their mechanical properties in respect of the possibility of technical applications on the aluminium alloy AW-7075 (among others, by the selection of optimum thicknesses on hard aluminium alloy), as well as the determination of the possibility of applying dispersion phases in order to improve their properties.
Źródło:
Advances in Science and Technology. Research Journal; 2018, 12, 2; 291-297
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nanoindentation measurements of AISI 316L SS biomaterial samples after annual immersion in Ringers solution followed by electrochemical polishing in a magnetic field
Badania nanoindentacji biomateriału stali AISI 316L po polerowaniu elektrolitycznym w polu magnetycznym i całorocznym zanurzeniu próbek w roztworze Ringera
Autorzy:
Rokosz, K.
Hryniewicz, T.
Valicek, J.
Harnicarova, M.
Vylezik, M.
Powiązania:
https://bibliotekanauki.pl/articles/151760.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
nanoindentacja
biomateriał AISI 316L
magnetoelektropolerowanie (MEP)
nanotwardość
moduł Younga
nanoindentation
316L biomaterial
magnetoelectropolishing (MEP)
nanohardness
Young's modulus
Opis:
Nanoindentation studies were performed on AISI 316L austenitic stainless steel after its electropolishing under varied conditions and keeping such obtained samples in the Ringer's solution for a year period of time. The Young's modulus of elasticity and hardness were investigated. The mechanical properties of AISI 316L stainless steel biomaterial demonstrated an evident dependence on the treated electropolishing conditions. After magnetoelectropolishing (MEP) treatment some improvement in mechanical properties of the same steel biomaterial is observed in comparison with the ones after a standard electropolishing (EP).
wykonanych z austenitycznej stali kwaso-odpornej AISI 316L. Próbki poddano polerowaniu elektrolitycznemu w warunkach standardowych (EP), oraz elektropolerowaniu w polu magnetycznym (MEP). Tak przygotowane próbki zostały zanurzone w roztworze Ringera i przetrzymane w temperaturze około 25 °C przez okres jednego roku. Po roku czasu próbki wyjęto, wypłukano w wodzie destylowanej i wysuszono. Następnie wykonano nanoindentację na urządzeniu do testowania 950 TriboIndenter™. Badano moduł sprężystości Younga oraz nanotwardość materiału. Wyniki badań pokazują, że własności mechaniczne stali AISI 316L zależą od warunków polerowania elektrolitycznego (EP). Po magnetoelektropolerowaniu (MEP) następuje poprawa niektórych własności mechanicznych biomateriału AISI 316L w porównaniu z wynikami uzyskanymi po standardowym elektropolerowaniu (po rocznym zanurzeniu próbek w roztworze Ringera). Wyniki badań są zgodne z dotychczasowymi rezultatami autorów i wskazują na możliwości modyfikacji wybranych właściwości mechanicznych biomateriałów metalowych, w tym przypadku - stali AISI 316L.
Źródło:
Pomiary Automatyka Kontrola; 2012, R. 58, nr 5, 5; 460-463
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ modyfikacji radiacyjnej i termicznej na właściwości funkcjonalne polietylenu
The influence of radiation and thermal modification on the functional properties of GUR 1050 polyethylene
Autorzy:
Maszybrocka, J.
Cybo, J.
Barylski, A.
Czaja, P.
Powiązania:
https://bibliotekanauki.pl/articles/189949.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
polietylen UHMW
modyfikacja radiacyjna
obróbka termiczna
twardość
moduł sprężystości
zużycie liniowe
UHMW polyethylene
radiation modification
thermal treatment
Young's modulus
hardness
linear wear
Opis:
W pracy przedstawiono metodę poprawy trwałości eksploatacyjnej UHMWPE przy jednoczesnym zapewnieniu wysokiej odporności oksydacyjnej polimeru. Materiał wyjściowy GUR 1050 (Poli Hi Solidur Medi TECH) został poddany sekwencyjnemu procesowi, który składał się z etapu modyfikacji radiacyjnej oraz obróbki termicznej. Ocenę skuteczności zastosowanej metody przeprowadzono za pomocą badań mikromechanicznych oraz testów tribologicznych na testerze T-01 (polimer/stop Vitalium). Stwierdzono nieznaczne zmniejszenie się charakterystyk mikromechanicznych (twardość i moduł Younga) wariantów poddanych sekwencyjnemu procesowi modyfikacji w stosunku do tylko napromieniowanych. Wyniki testów tribologicznych wykazują jednak wzrost odporności na zużycie w porównaniu z materiałem niemodyfikowanym i jej niezmienioną wartość w stosunku do polimeru napromieniowanego.
This paper presents a method of improving the operational durability of UHMWPE, while ensuring high oxidation resistance of the polymer. The initial material, GUR 1050 (Poly Hi Solidur Medi TECH), underwent a sequential process consisting of a stage of modification through radiation, and a stage of thermal processing. The assessment of the effectiveness of the applied method was performed using micromechanical examination and tribological tests using a T-01 (polymer/Vitalium alloy) tester. It was found that there was a slight decrease in the micromechanical characteristics (hardness and Young's modulus) for the variants subjected to the sequential modification process compared to the variants only irradiated. However, the tribological test results show an increase in resistance to wear compared to unmodified material, and unchanged resistance to wear compared to the irradiated polymer.
Źródło:
Tribologia; 2012, 4; 167-173
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of the Effect of Young’s Modulus on the Contact Strength of Metal Polymer Plain Bearings
Autorzy:
Chernets, Myron
Pashechko, Mykhaylo
Kornienko, Anatolii
Borc, Jarosław
Zakhariia, Roman
Powiązania:
https://bibliotekanauki.pl/articles/2181749.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
metal-polymer plain bearings
epoxy composites
Moglice
DK6 (PT)
polyamide composites
PA6+30%GF
PA6+30%CF
calculation method
Young modulus
Young module
maximum contact pressures
Opis:
Using the author's method of research of hybrid (metal-polymer) plain bearings the calculation of their load carrying capacity (contact pressures) is carried out. Studies have been conducted for metal-polymer bearings with a bushing of two types of polymer composites: epoxy based antifriction composite materials DIAMANT Moglice (DIAMANT Metallplastic GmbH) and DK6 (PT) (fillers - graphite, MoS2, Zr). The elastic constants of composite materials, in particular the Young's modulus, have a noticeable effect on the contact pressures in metal-polymer bearings. The Young's modulus is significantly different in these composite materials. In accordance with this factor, the influence of load, bushing diameter and radial clearance on the maximum contact pressures was studied. Quantitative and qualitative regularities of maximum contact pressures from the accepted factors of influence: Young's modulus, loading, bushing diameter, radial clearance, type of bushing material are established. The obtained results are compared with the results obtained by known conventional calculating methods of contact pressures.
Źródło:
Advances in Science and Technology. Research Journal; 2022, 16, 2; 67--73
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena skuteczności napromieniowania wiązką elektronów w aspekcie podwyższania odporności na zużycie polietylenów GUR 1020 i GUR 1050 stosowanych na panewki endoprotez
Evaluation of electron beam irradiation effectiveness in view of increasing wear resistance of GUR 1020 and GUR 1050 polyethylenes used for endoprosthesis cups
Autorzy:
Barylski, A.
Cybo, J.
Maszybrocka, J.
Czaja, P.
Powiązania:
https://bibliotekanauki.pl/articles/189986.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
polietylen UHMW
modyfikacja radiacyjna
odkształcenie polimeru
twardość
moduł sprężystości
zużycie masowe i liniowe
UHMW polyethylene
radiation modification
polymer deformation
Young's modulus
hardness
mass wear
linear wear
Opis:
W celu zwiększenia odporności polietylenu GUR 1020 i GUR 1050 na odkształcenie plastyczne i zużycie ścierne przeprowadzono modyfikację radiacyjną. Stosowano napromieniowanie elektronami o dawce 26-156 kGy. Wraz ze wzrostem dawki napromieniowania odnotowano zwiększenie twardości i modułu sprężystości podłużnej. Stwierdzono również, że GUR 1050 (o ciężarze cząsteczkowym 9,2•106 g/mol) cechuje się 1,86 razy większą odpornością na trwałą deformację. Wskazuje to na ścisły związek właściwości polimerów z ciężarem cząsteczkowym, który dla GUR 1020 wynosi 5•106 g/mol. Potwierdzenie stanowi mniejsza wartość zużycia tribologicznego GUR 1050 niż GUR 1020, która już w stanie wyjściowym polimerów przekracza 20%. Testy tribologiczne przeprowadzone na testerach T-05 i T-01 dowodzą, że napromieniowanie elektronami (6×26 kGy) obu polimerów powoduje 4-krotne zmniejszenie zużycia w stosunku do polietylenów niemodyfikowanych. Uzyskane wyniki dowodzą skuteczności modyfikacji radiacyjnej, która rokuje możliwość wydłużenia czasu użytkowania panewek endoprotez.
Radiation modification was conducted in order to increase the resistance of GUR 1020 and GUR 1050 polyethylenes to plastic deformation and abrasive wear. Electron irradiation of 26-156 kGy dose was applied. It was determined that the hardness and longitudinal elasticity module increase along with the increase in the dose of radiation. It was also found that GUR 1050 (of a molecular weight of 9.2•106 g / mol) is characterised by a 1.86 times greater resistance to permanent deformation. This indicates a close relationship between the properties of polymers and molecular weight, which for the GUR 1020 is 5•106 g/mol. This is corroborated by a lower value of tribological wear of GUR 1050 compared to GUR 1020, which already exceeds 20% in the initial state of polymers. Tribological tests conducted on the T-05 and T-01 testers have shown that electron irradiation (6x26 kGy) of both polymers result in a four-fold reduction in wear as compared to unmodified polyethylenes. The obtained results demonstrate the effectiveness of radiation modification, which promises the possibility of extending the service life of endoprosthesis cups.
Źródło:
Tribologia; 2012, 4; 17-23
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ modyfikacji radiacyjnej elektronami na deformację plastyczną, właściwości mechaniczne oraz zużycie polietylenu GUR 1050, stosowanego na panewki endoprotez
The influence of e-beam radiation on plastic deformation, mechanical properties and wear of the polyethylene GUR 1050 for acetabular cups
Autorzy:
Barylski, A.
Cybo, J.
Maszybrocka, J.
Czaja, P.
Powiązania:
https://bibliotekanauki.pl/articles/189777.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
polietylen UHMWPE
modyfikacja radiacyjna
obciążenie eksploatacyjne
odkształcenie polimeru
twardość
moduł Younga
zużycie masowe
zużycie liniowe
UHMW polyethylene
radiation modification
operational load
polymer deformation
hardness
Young's modulus
mass wear
linear wear
Opis:
Odporność polietylenu na zużycie i deformację trwałą wpływa na trwałość polimerowo-metalowych układów kinematycznych. Z myślą o zwiększeniu trwałości zabiegów alloplastyki został wprowadzony polimer GUR 1050 o ciężarze cząsteczkowym 9,2*106 g/mol, który przeznaczony jest zwłaszcza na implanty medyczne. Uzasadnia to celowość oceny odporności tego materiału na zużycie i odkształcenie, a także stwierdzenie, czy jego właściwości użytkowe można podwyższyć poprzez modyfikację radiacyjną. Próbki polimeru wyjściowego (bazowego) napromieniowano elektronami, stosując krotność napromieniowania I = 1–6 dawką 26 kGy. Analiza zmian wartości odkształcenia pod wpływem obciążeń eksploatacyjnych wykazała wzrost odporności polietylenu na deformację trwałą w wyniku zastosowanego napromieniowania. Poprawa właściwości mechanicznych została potwierdzona badaniami mikroindentacyjnymi. Stwierdzono wzrost twardości i modułu Younga. Efekt ten jest zachowany mimo przeciwnego trendu, który wywołuje rosnący stopień deformacji plastycznej polimeru pod wpływem obciążenia. Badania tribologiczne wykazały znaczący wzrost (ok. 4 razy) odporności na zużycie ścierne polietylenu modyfikowanego radiacyjnie. Znaczne ograniczenie zużycia rokuje dłuższy okres współpracy węzła tarcia, co wydłuży czas użytkowania panewki w ludzkim organizmie. Przedstawione w pracy wyniki dowodzą skuteczności modyfikacji radiacyjnej, która podwyższa badane właściwości funkcjonalne proporcjonalnie do zastosowanej dawki napromieniowania elektronami.
The resistance of polyethylene to wear and permanent deformation influences the durability of polymer-metal kinematic systems. The recently introduced polyethylene, GUR 1050, of a molecular weight of 9.2 * 106 g/mole is intended especially for medical implants. This justifies the need for evaluating the resistance of this material to wear and deformation and for determining if its functional properties can be improved by radiation modification. Samples of the initial (base) polymer were electron-irradiated with applying an irradiation multiplication factor I = 1–6 and a dose of 26 kGy. An analysis of changes in the deformation value under the influence of operational loads has shown an increase in the polyethylene resistance to permanent deformation as a result of the irradiation applied. The improvement of mechanical properties has been confirmed in micro-indentation tests. An increase in the hardness and Young's modulus was identified. This effect has been preserved despite an opposite trend that causes a growing level of plastic deformation of the polymer under the influence of load. Tribological tests have shown a significant increase (by ca. 4 times) in the resistance to abrasive wear of the polyethylene modified through irradiation. The significant wear reduction prognosticates a longer life of the friction couple, which will prolong the durability of acetabular cups in the human organism. The test results presented in the paper prove the effectiveness of modification through irradiation that enhances the tested functional properties proportionally to the applied dose of electron irradiation.
Źródło:
Tribologia; 2011, 5; 11-20
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The evaluation by means of microindentation and sclerometry of changes in properties after electron beam irradiation of polyethylene GUR 1050
Diagnozowanie metodą mikroindentacji i sklerometrii zmian właściwości po napromieniowaniu strumieniem elektronów polietylenu GUR 1050
Autorzy:
Barylski, A.
Cybo, J.
Maszybrocka, J.
Powiązania:
https://bibliotekanauki.pl/articles/187925.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
modyfikacja radiacyjna
obciążenie eksploatacyjne
odkształcenie polimeru
mikromechanizm zużycia ściernego
wskaźnik odporności na zużycie
twardość
moduł Younga
radiation modification
operational load
polymer deformation
abrasive wear micromechanism
resistance to wear ratio
hardness
Young's modulus
Opis:
With the aim to increase the resistance of GUR 1050 polyethylene to plastic deformation and abrasive wear, modification through radiation was applied. Compression tests of up to 300 MPa showed an increase in resistance to permanent deformation. This has been confirmed with microindentation and sclerometry tests. Scratch test indicated a lower tendency of the carved material to chipping than to uplift in all operational deformations. The domination of the micromechanism of the formation of ridges allows the material to retain a small decrease in resistance to wear. The parameters of microtests may be used for the purpose of the evaluation and selection of the polymers used in friction joints in medicine and technology.
W celu podwyższenia odporności polietylenu GUR 1050 na odkształcenie plastyczne i zużycie ścierne zastosowano modyfikację radiacyjną. Badania w zakresie naprężeń do 300 MPa wykazały wzrost odporności na deformację trwałą. Potwierdzono to testami mikroindentacyjnymi i sklerometrycznymi. Scratch test wykazał, że w całym zakresie odkształceń eksploatacyjnych występuje mniejsza skłonność do wykruszania materiału wyżłobionego niż do jego plastycznego wypiętrzania. Dominacja mikromechanizmu bruzdowania pozwala zachować niewielki spadek odporności na zużycie. Parametry mikrotestów mogą być wykorzystywane do diagnozowania i selekcji polimerów stosowanych w medycznych oraz technicznych węzłach tarcia.
Źródło:
Tribologia; 2012, 2; 23-29
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Magnetoelectropolishing: modern and effective method of AISI 316L SS surface finishing
Magnetoelektropolerowanie jako nowa i efektywna metoda obróbki powierzchniowej stali austenitycznej AISI 316L
Autorzy:
Rokosz, K.
Hryniewicz, T.
Powiązania:
https://bibliotekanauki.pl/articles/155250.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
AISI 316L SS
magnetoelectropolishing (MEP)
XPS measurements
potentiodynamic measurements
nanoindentation
nanohardness
reduced Young's modulus
Cr-X/Fe-X ratio
magnetoelektropolerowanie (MEP)
pomiary XPS
pomiary potencjodynamiczne
nanoindentacja
nanotwardość
zredukowany moduł Younga
stal austenityczna AISI 316L
stosunek Cr-X/Fe-X
Opis:
The results presented in the paper have been obtained during several last years. They represent chemical composition of the passive layer measurements, its uniform and pitting corrosion resistance as well as nanohardness and reduced Young's modulus for the austenitic steel AISI 316L. The main goal is to present a new and modern method of finishing - electrochemical polishing in a magnetic field MEP with respect to the standard abrasive polishing MP and electrochemical one EP. The chemical composition of the surface layer of AISI 316L were examined using X-ray photoelectron spectroscopy (XPS); the corrosion rates were determined from potentiodynamic polarization tests. Nanohardness and reduced Young's modulus were obtained from nanoindentation measurements. The main achievement of the paper is revealing the chemical and mechanical properties of the surface layer formed after polishing MEP against the MP and EP treatments.
W artykule przedstawiono kompaktowo wyniki kilkuletnich badań i pomiarów składu chemicznego warstwy pasywnej, jej odporności na korozję równomierną oraz wżerową, jak i nanotwardość oraz zredukowany moduł Younga dla austenitycznej stali AISI 316L. Autorzy zaprezentowali nowoczesną metodę obróbki wykończeniowej – elektrochemiczne polerowanie w polu magnetycznym MEP w odniesieniu do standardowej obróbki ściernej MP oraz elektrochemicznej EP. Skład chemiczny warstwy wierzchniej stali AISI 316L zbadano przy użyciu fotoelektronowej spektroskopii promieniami Roentgena (XPS); szybkości korozji wyznaczono z badań potencjodynamicznych, a nanotwardość oraz zredukowany moduł Younga z badań nanoindentacyjnych. Głównym przedmiotem pracy jest prezentacja wpływu pola magnetycznego na własności chemiczne oraz mechaniczne warstwy wierzchniej powstałej po polerowaniu MEP na tle obróbek MP i EP. Przeprowadzone badania wykazały, że odporność na korozję wżerową powierzchni po elektrochemicznym polerowaniu w polu magnetycznym MEP wzrasta około dwukrotnie w stosunku do standardowego polerowania elektrochemicznego EP, co potwierdzają również wyniki badań XPS, obrazujące stosunek związków chromu do związków żelaza. Odnotowano również zmianę nanotwardości oraz zredukowanego modułu Younga warstw wierzchnich otrzymanych poprzez obróbkę EP i MEP, co dodatkowo potwierdza istotny wpływ pola magnetycznego na właściwości zarówno elektrochemiczne jak i mechaniczne warstwy wierzchniej.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 12, 12; 1304-1307
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-13 z 13

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies