Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "fractions" wg kryterium: Temat


Wyświetlanie 1-7 z 7
Tytuł:
Safety in Rough Milling of Magnesium Alloys Using Tools with Variable Cutting Edge Geometry
Autorzy:
Zagórski, Ireneusz
Powiązania:
https://bibliotekanauki.pl/articles/2201905.pdf
Data publikacji:
2023
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
magnesium alloys
rough milling
time to ignition
ignition temperature
chip mass
chip fractions
fragmentation
Opis:
This paper presents the results of a study investigating the problem of safety in dry milling magnesium alloy AZ91D. Selected indicators of safe machining were analyzed, including time to ignition, ignition temperature, chip mass and morphology. Experiments were performed using carbide end mills with a variable edge helix angle. It was observed that magnesium alloys could be dry milled without the risk of chip ignition. The milling process conducted with the axial depth of cut ap set to 6 mm was found to be optimum (a great amount of leading fraction A was produced). Unfortunately, however, some machining conditions proved to be inductive to the formation of chip powder known as magnesium dust. For most cases, chips obtained using the tool with λs 50° had higher unit mass than those obtained with λs 20°. Metallographic images of chips confirmed the safe range of the machining parameters employed (no partial melting or burn marks were observed). Determined on a specially designed test stand outside of the machine tool, time to ignition can be an effective parameter for performing simplified chip ignition simulations.
Źródło:
Advances in Science and Technology. Research Journal; 2023, 17, 2; 181--191
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rejestracja i ocena ilościowa niestabilnych białek surowicy krwi
Registration and quantitative analysis of serum proteins of unstable structure
Autorzy:
Roterman-Konieczna, I.
Konieczny, L.
Rybarska, J.
Piwowar, P.
Powiązania:
https://bibliotekanauki.pl/articles/154881.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
surowica krwi
frakcje białkowe
białka ostrej fazy
ligand ciekłokrystaliczny
blood serum
protein fractions
acute phase proteins
supramolecular ligand
Opis:
Niektóre liotropowe układy ciekłokrystaliczne tworzące taśmowe układy micelarne mają zdolność tworzenia kompleksów z białkami pod warunkiem możliwości penetracji do wnętrza bryły białkowej. Możliwość taką stwarzają białka o niestabilnej strukturze w tym głównie białka patologiczne a także część białek należących do białek ostrej fazy. Modyfikacja ładunku białka w wyniku kompleksowania może być ujawniona w rozdziale elektroforetycznym. Dwukierunkowy rozdział elektroforetyczny z dodatkiem liganda supramolekularnego w drugim prostopadłym kierunku rozdziału pozwala na ujawnienie i izolację kompleksów z ciekłokrystalicznym ligandem. Otwiera to istotne możliwości diagnostyczne. Oczekiwane jest opracowanie numerycznej techniki ilościowej oceny proporcji ujawnionych frakcji białkowych. Wiązanie ligandów ciekłokrystalicznych okazuje się też aktualne w przypadku kompleksowania ich przez złogi amyloidowe. Czerwień Kongo jest w tym przypadku markerem specyficznym.
Some lyotropic liquide crystals of ribbon-like micellar structure form complexes with proteins of unstable structure due to possible penetration to their interior. Misfolded proteins and some acute phase serum proteins belong to that group. The altered charge of proteins engaged in complexation which becomes modified by the charge of bound ligand affects electrophoretic migration and allows differentiation of ubnormal proteins from among serum proteins. Two-dimensional agarose electrophoresis of serum proteins undergone complexation with supramolecular ligand after perpendicular reorganization of migration fulfils the requirement. The exposure of misfolded proteins and their quantitative analysis has a significant diagnostic meaning. Elaboration of numerical analysis is expected. Ligands in form of liquide crystals have been found to be bound to amyloids. Congo red appeared to be the specific marker for recognition of amyloid fibrils. This type of ligand seems to be the new category of ligands complexes in form of multimolecular system.
Źródło:
Pomiary Automatyka Kontrola; 2012, R. 58, nr 4, 4; 379-382
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Udziały objętościowe faz w warunkach spływu w rurze pionowej cieczy dwufazowej woda-olej
Volume fraction of phases during water-oil two-phase liquid downflow in a vertical pipe
Autorzy:
Brandt, A.
Witczak, S.
Powiązania:
https://bibliotekanauki.pl/articles/2072674.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
spływ grawitacyjny cieczy dwufazowej
struktury przepływu
udział objętościowy faz
gravitational liquid flow
flow patterns
volume fractions of phases
Opis:
W pracy przedstawiono wyniki badań związanych z określeniem wartości udziałów objętościowych faz oraz rodzajów tworzących się struktur podczas spływającej w rurze pionowej cieczy dwufazowej typu woda-olej. Opracowano oryginalną mapę przepływu oraz podano zależność do obliczania udziału objętościowego oleju.
The paper presents the results of studies related to the determination of volume fraction of phrases and types of flow pattern formed during water-oil two-phase flow map was elaborated and the dependency for oil volume fraction calculation was given.
Źródło:
Inżynieria i Aparatura Chemiczna; 2016, 1; 10--11
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Niepewność pomiaru długich płytek wzorcowych na zmodernizowanym komparatorze interferencyjnym
The uncertainty of measurement of long gauge blocks with a modernized interferometric comparator
Autorzy:
Szumski, R.
Powiązania:
https://bibliotekanauki.pl/articles/153674.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
długie płytki wzorcowe
interferencja
światło białe
metoda reszt ułamkowych
niepewność pomiaru
end standards
long gauge blocks
interferometry
method of exact fractions
Opis:
Dla zmodernizowanego komparatora interferencyjnego do wzorcowania długich płytek wzorcowych o długości do 500 mm została oszacowana niepewność pomiaru. Stanowisko umożliwia wykonywanie pomiarów metodą opartą na detekcji końców płytki mierzonej z wykorzystaniem efektu interferencji w świetle białym i pomiarze przemieszczenia zwierciadła odniesienia interferometrem laserowym, która została uzupełniona o dokładniejszą metodę reszt ułamkowych opartą na dwóch stabilizowanych laserach He-Ne. Przedstawiona została analiza równania pomiaru i źródeł niepewności pomiaru dla obu metod, wraz z budżetem niepewności. Słowa kluczowe: długie płytki wzorcowe, interferencja, światło białe, metoda reszt ułamkowych, niepewność pomiaru.
The measurement uncertainty for a modernized gauge block interferometer for long gauge blocks up to 500 mm, used in the Length Laboratory of Length and Angle Division of GUM, was evaluated. After modernization the measurement of gauge blocks with the modernized set-up may be carried out using the method applied so far. The method consists in using the low coherence white light for detection of gauge block ends by interference and measuring the reference mirror displacement corresponding to the length of the gauge block measured by the Renishaw interferometer. After modernization the more accurate method of exact fractions based on interference of two stabilized He-Ne laser light is also possible. The model equations and the detailed analysis of the uncertainty sources with the uncertainty budget and the expanded uncertainty are presented. The uncertainty budgets for both methods show that they have many common contributions.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 8, 8; 533-536
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary długich płytek wzorcowych na zmodernizowanym stanowisku pomiarowym z interferometrem laserowym
Calibration of long gauge blocks using the modernized setup with a laser interferometer
Autorzy:
Szumski, R.
Powiązania:
https://bibliotekanauki.pl/articles/158417.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
wzorce końcowe
długie płytki wzorcowe
komparator interferencyjny
interferencyjna metoda reszt ułamkowych
end standards
long gauge blocks
interferometry
method of exact fractions
Opis:
Stosowany od lat w Laboratorium Długości Zakładu Długości i Kąta GUM, komparator interferencyjny do wzorcowania długich płytek wzorcowych o zakresie pomiarowym do 500 mm, został poddany modernizacji. Metoda pomiarowa wykorzystywana na stanowisku pomiarowym oparta na efekcie interferencji w świetle białym, została uzupełniona o metodę reszt ułamkowych (ang. exact fractions) opartą na laserowych źródłach światła. Wprowadzone zmiany w układzie pomiarowym związane są przede wszystkim z doprowadzeniem do układu optycznego odpowiednio uformowanej wiązki światła laserowego ze światłowodu. Zastosowano ponadto nowe rozwiązanie w zakresie adiustacji zwierciadła odniesienia podczas wykonywania pomiarów, dzięki czemu został zredukowany problem ze znaczącym wpływem odchylenia od prostoliniowości ruchu karetki pomiarowej na niepewność pomiaru.
The gauge block interferometer for long gauge blocks up to 500 mm, used for years in the Length Laboratory of Length and Angle Division of GUM, was modernized. The measuring method used on the measuring setup based on the interference in white light, was supplemented with the method of exact fractions based on laser light sources. The measurement of gauge blocks with the modernized setup may be carried out using the method applied so far, which involves the use of the low coherence white light to detection of gauge block ends by interference and the measuring of the reference mirror displacement corresponding to the length of a gauge block measured by the Renishaw interferometer. After modernization the measurement with use of laser light interference is also possible. For the method of exact fractions, two stabilized He-Ne lasers with wavelengths of 633 nm and 543 nm are used as the standards. The main changes of the measuring system are related to providing a properly formed laser light beam from optical fiber and additional optical elements to the optical system. Moreover, a new solution for the reference mirror adjustment during measurement has been applied. Due to it, the problem with non-rectilinear slideways of the measuring carriage has been reduced. Validation of the methods was carried out during the within-laboratory comparisons. The uncertainty budget analysis and measurement results of long gauge blocks show that both method complement each other.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 4, 4; 304-307
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania hydrauliki układów wodno-olejowych
Research of hydrodynamics of water-oil systems
Autorzy:
Troniewski, L.
Witczak, S.
Mydlarz-Gabryk, K.
Powiązania:
https://bibliotekanauki.pl/articles/2070913.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
struktura przepływu
mapa przepływu
udział objętościowy faz
strata ciśnienia
inwersja faz
flow patterns
flow map
void fractions
pressure drop
phase inversion
Opis:
W artykule, przedstawiono wyniki badań przepływu dwufazowego woda olej w rurach pionowych. Omówiono wpływ parametrów przepływu i właściwości faz na rodzaj kształtujących się struktur, rzeczywiste udziały objętościowe faz oraz straty ciśnienia.
The paper presents test results of water-oil two-phase flow in vertical pipes. An influence of flow parameters and properties of phases on a type of formed flow structures, void fractions and pressure drop is discussed.
Źródło:
Inżynieria i Aparatura Chemiczna; 2010, 2; 121-122
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Struktury przepływu trójfazowego gaz - ciecz - ciecz w łuku rurowym
Gas - liquid - liquid three-phase flow patterns in a pipe bend
Autorzy:
Pietrzak, M.
Witczak, S.
Powiązania:
https://bibliotekanauki.pl/articles/2070865.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
struktury przepływu
łuk rurowy
przepływ trójfazowy gaz-ciecz-ciecz
mapa przepływu
udziały objętościowe
flow patterns
pipe bend
three-phase flow
flow map
void fractions
Opis:
W pracy przedstawiono wyniki badań dotyczących obserwacji struktur przepływu, jak również pomiarów udziałów objętościowych faz przy przepływie mieszaniny trójfazowej powietrze — woda — olej przez łuk rurowy. W wyniku przeprowadzonych badań zidentyfikowano formy przepływu trójfazowego, opracowano mapę takiego przepływu oraz określono wartości udziałów objętościowych powietrza.
Test results of hydrodynamics of three-phase flow in a pipe bend are presented in the paper. Types of flow patterns formed in a pipe bend and values of void fractions of air were determined. A map of three-phase flow in a pipe bend was elaborated.
Źródło:
Inżynieria i Aparatura Chemiczna; 2009, 6; 148-149
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies