Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "experimental measurement" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
The analysis of thermocouple time constants as a function of fluid velocity
Autorzy:
Majdak, M.
Jaremkiewicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/114056.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
time constant
thermocouple
transient temperature measurement
experimental analysis
Opis:
In steady-state conditions when the fluid temperature is constant, there is no damping and time lag so the temperature measurement can be performed with a high accuracy. But when the fluid temperature is varying rapidly as during the start-up, quite appreciable differences occur between the exact and measured temperature because of the time required for the transfer of heat to the thermocouple placed inside a thermometer pocket. The temperature of the fluid is one of the key parameters affecting the proper operation of thermodynamic cycles, so the precise determination of its value is very important. The speed of the response of control systems to a temperature change is closely related to the time constant of the used thermocouples. The paper presents a significant impact of fluid velocity changes (in this case air) on the value of time constants of thermometers. For this purpose, the experimental study was carried out using sheathed thermometers with different diameters and hot junctions. The time constants determined for various thermometers are compared.
Źródło:
Measurement Automation Monitoring; 2016, 62, 9; 284-287
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental assessment of roundness profile measurement using the coordinate technique
Eksperymentalna ocena pomiaru zarysów okrągłości współrzędnościową techniką pomiarową
Autorzy:
Adamczak, S.
Jarema, M.
Powiązania:
https://bibliotekanauki.pl/articles/152534.pdf
Data publikacji:
2008
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
zarys okrągłości
pomiar
współrzędnościowa maszyna pomiarowa
eksperymentalny błąd metody
measurement
roundness profile
coordinate measuring machine
experimental method error
Opis:
Measurement laboratories in large production facilities with a stabilized and unchangeable production profile are equipped in accordance with the profile. In smaller companies where the profile is changeable, laboratories need to have more universal equipment. Frequently, a universal coordinate measuring machine is purchased to perform some basic tasks such as measurement of geometrical quantities, e. g. length or angle and assessment of selected parameters of geometrical surface structure, e.g. form and position deviation. The paper studies the accuracy of a typical coordinate measuring machine equipped with a pulse head applied to measurements of roundness profiles.
Duże zaklady przemysłowe o ustabilizowanym i niezmiennym profilu produkcji mają laboratoria pomiarowe wyposażone zgodnie z profilem swojej produkcji. Inna sytuacja jest w mniejszych firmach o zmiennym profilu produkcji. Tam laboratoria pomiarowe muszą być wyposażone w sprzęt pomiarowy o charakterze bardziej uniwersalnym. Rozwiązaniem tego problemu może być zakup współrzednościowej maszyny pomiarowej. Maszyny pomiarowe dzięki swojej uniwersalności stwarzają możliwość realizacji pomiarów podstawowych wielkości geometrycznych (dlugości i kąta). Umożliwiają również ocenić niektórych parametrów struktury geometrycznej powierzchni takich jak odchyłki ksztaltu i położenia. W artykule wyznaczono dokladność WMP w przypadku pomiaru zarysów okrągłoki dla typowej współrzednościowej maszyny pomiarowej wyposażonej w głowice impulsową.
Źródło:
Pomiary Automatyka Kontrola; 2008, R. 54, nr 5, 5; 251-253
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiar wybranych parametrów biomechanicznych w trakcie realizacji
Measurements of selected biomechanical parameters during experimental studies of an implant-bone connection
Autorzy:
Zaczyk, M.
Jasińska-Choromańska, D
Powiązania:
https://bibliotekanauki.pl/articles/153011.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiary biomechaniczne
eksperymentalne badania połączenia implant-kość
jakość osadzenia implantu w tkance kostnej
biomechanical measurement
experimental tests implant-bone
Opis:
Praca przedstawia jedną z metod badania osadzenia implantu w tkance kostnej. Opisano metodykę badań, dzięki której możliwa jest ocena jakości osadzenia implantu w tkance kostnej. W badaniach eksperymentalnych nowo poznawanych zjawisk kluczowe staje się odpowiednie dobranie aparatury pomiarowej. Poprawny dobór przyrządów pomiarowych pozwala na jednoznaczny opis badanego zjawiska lub obiektu.
The paper presents one of the methods of testing an implant mounting within the osseous tissue. It describes a methodology of the studies, which makes it possible to evaluate quality of the implant mounting within the osseous tissue. In the case of experimental studies of new phenomena being just investigated, it is crucial to appropriately select the measurement equipment. A correct selection of the measuring instruments allows one to unequivocally describe the studied phenomenon or object. A specific character of biomechanical properties of bones makes it impossible to carry out experiments using universal measuring machines, what results in a necessity of building custom test stations as well as special measure-ment systems based on well-developed measurement applications. As far as the described method of testing is concerned, there can be distinguished the following three stages:- the first, including preparations of the objects for the studies,- the second, including carrying out of measurements using the objects that have been prepared beforehand,- the third, including analytical determination of numerical values of the studied parameters. At the first stage, a minimum of the sample should be prepared, using an osseous tissue taken from a closer shaft of a cow thigh bone. After a pretreatment of the bone, a fragment of the tested mandrel should be mounted within it. The test station for experimental studies of the mandrel mounting within the osseous tissue must ensure a possibility of a real-time recording of the related displacements and load forces. The experiment was repeated many times in order to minimize the scatter of the indications. Basing on the obtained results, mutual correlations of particular data were determined, e.g. displacements of the mandrel within the bone in relation to the applied load. The obtained results make it possible to specify what kind of dynamics of the load applying influences the osseous tissue reaction rate.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 6, 6; 575-578
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena dokładności wyników eksperymentalnego badania połączenia implant-kość
Result accuracy evaluation of experimental studies of an implant-bone connection
Autorzy:
Zaczyk, M.
Jasińska-Choromańska, D.
Kołodziej, D.
Powiązania:
https://bibliotekanauki.pl/articles/153013.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiary biomechaniczne
eksperymentalne badania połączenia implant-kość
jakość osadzenia implantu w tkance kostnej
biomechanical measurement
experimental tests implant-bone
implant fixation quality in the bone
Opis:
Praca zawiera opis metodyki wyznaczenia niepewności dla pomiarów biomechanicznych realizowanych podczas badań eksperymentalnych osadzenia implantu w tkance kostnej. Przedstawiona procedura szacowania niepewności pozwoliła określić, które z etapów procesu pomiarowego eksperymentu miały znaczący wpływ na błędy wyników i z jaką ufnością można podchodzić do wartości liczbowych, opisujących badaną własność biomechaniczną.
The paper presents a methodology of determining uncertainty in biomechanical measurements realized during experimental studies of an implant mounting within an osseous tissue. The presented procedure of evaluating the uncertainty allows one to determine which of the stages of the measurement process of the experiment had a significant influence on the errors of the obtained results, and how much is a confidence level corresponding to the numerical values describing a studied biomechanical property. Values of biomechanical properties are usually obtained in an experimental way. A unification of the analysis of the studies is a decisive factor with respect to the reliability and usability of the results, as well as a possibility of comparing these values for a given property obtained in other experiment. Analysis of the sources of the measurement uncertainties with respect to the realized process of recording the given numeric values of the properties searched for, provided it has been carried out reliably, allows one to create a mathematical equation of the related process. Analysis of evaluating uncertainty related to the presented experiment proved that both the measurement equipment and the methodology of experimental studies were selected correctly, and the most significant influence on the resultant errors had its source in biomechanical properties of the materials used for building the object of experiments. It was impossible to eliminate error sources related to the applied osseous material, since each bone used for building a sample originated from a different specimen, having at the same time its own individual characteristics.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 6, 6; 579-582
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies