Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "bushing" wg kryterium: Temat


Wyświetlanie 1-10 z 10
Tytuł:
Analysis of suspension element of car body on the example silentblock
Autorzy:
Ziobro, J.
Powiązania:
https://bibliotekanauki.pl/articles/101946.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
silentblock
rubber-metal bushing
rubber
FEM simulation
Opis:
The article presents a still important aspect of the construction and operation of the vehicle. The most loaded part of the suspension of a vehicle has been discussed, for example, rubber-metal bushing (silentblock). This component directly affects the safety and comfort of drive. It also presents the main varieties of construction and signs of usage of those elements. It has comprised of properties of the rubber and polyurethane bushings. Mechanical calculation of silentblock model has also been presented. 3D numerical analysis was carried out on the basis of the model by using two types of rubber bushings with different hardness. The results of simulations carried out in the system MSC.MARC has been shown. On these basis, there were selected and given numerous conclusions for utilitarian character.
Źródło:
Advances in Science and Technology. Research Journal; 2015, 9, 28; 125-129
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bubble effect w izolatorach przepustowych o izolacji wykonanej z różnych materiałów
Bubble effect in bushing insulators of insulation consisting of different materials
Autorzy:
Przybyłek, P.
Morańda, H.
Mościcka-Grzesiak, H.
Powiązania:
https://bibliotekanauki.pl/articles/153919.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
izolator przepustowy
efekt bąbelkowania
bushing insulator
bubble effect
Opis:
W artykule przedstawiono wyniki badań modeli izolatorów przepustowych w aspekcie możliwości wystąpienia w nich bubble effect. Badaniu poddano trzy rodzaje układów izolacyjnych: papier - olej mineralny, papier żywicowany - olej mineralny oraz papier - olej syntetyczny. Głównym efektem pracy jest wykazanie możliwości wystąpienia bubble effect w izolatorach przepustowych. Stwierdzono, że zamiana syciwa z oleju mineralnego na syntetyczny może spowodować zmianę warunków wystąpienia bubble effect.
The purpose of the research was to answer the question: is there any possibility of appearing the bubble effect in a bushing insulator? The bubble effect can appear under particular operating conditions, i.e. substantial moisture and high insulation temperature. In the second section of the paper, the reason for temperature increase in the bushing insulator insulation model is explained. In new bushing insulators of good dielectric properties of insulation, the source of heat are power losses resulting from a flowing current. In old moistened bushing insulators, another source of heat are dielectric losses. There were investigated three kinds of insulation models: paper-mineral oil, paper-synthetic oil and resin bounded paper-mineral oil. Construction of the bushing insulation models investi-gated is described in the third section. In the fourth section the investigation results and conclusions are presented. The main conclusion of the work is that the bubble effect can appear in a bushing insulator (Figs. 2-4). It can also be stated that the change of mineral oil into synthetic ester causes the increase in the bubble effect initiation temperature.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 4, 4; 406-408
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ starzenia termicznego w warunkach eksploatacyjnych na odpowiedź dielektryczną przepustu typu RBP
Influence of thermal ageing under operating conditions on the dielectric response of RBP type bushings
Autorzy:
Mrozik, A.
Zenker, M.
Powiązania:
https://bibliotekanauki.pl/articles/152067.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
diagnostyka
starzenie
przepust RBP
FDS
diagnostics
aging
RBP bushing
Opis:
W artykule zaprezentowano wyniki badań wpływu starzenia termicznego w warunkach zbliżonych do eksploatacyjnych na odpowiedź dielektryczną izolacji przepustu RBP. Stwierdzono, że pomiary wykonane dla dużego gradientu temperatury w izolacji stwarzają możliwość zaobserwowania relaksacji warstw położonych w okolicy toru prądowego. Natomiast pomiary wykonane dla stałej temperatury dają sumaryczną odpowiedź całej objętości izolacji. Analiza jakościowa odpowiedzi dielektrycznej przepustu z zastosowaniem równania H-N wykazała istnienie procesów polaryzacyjnych w zakresie niskich częstotliwości, których stałe czasowe zależą od stopnia zestarzenia izolacji i gradientu temperatury po promieniu rdzenia.
The paper presents results of the research on influence of thermal ageing under conditions similar to the operating ones on the dielectric response of RBP bushing insulation. The thermal ageing of insulation under operating conditions was simulated by increasing the temperature of a bushing conductor to T = 800C, at constant ambient temperature T ≈ 10÷12 ºC. Measurements of tgδ and capacitance were taken with the FDS method at various temperatures of the conductor. The analysis of the test results showed that thermal ageing led to the shortening of time constants of polarization processes. It was found that the measurements taken for a large gradient of the temperature in insulation allowed observation of its relaxation for layers located near the conductor. The measurements taken for a constant temperature gave the cumulative response of the whole insulation capacity. The qualitative analysis of the bushing dielectric response with the H-N equation showed existence of polarization processes in the low frequency range, with time constants depending on the insulation ageing level and the temperature gradient along the core radius.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 2, 2; 161-163
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie pomiarów termowizyjnych do diagnostyki transformatorowych przepustów WN
The use of thermovision measurements for diagnostics of HV transformer bushings
Autorzy:
Subocz, J.
Mrozik, A.
Powiązania:
https://bibliotekanauki.pl/articles/154128.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
temperatura
termowizja
przepust WN
diagnostyka
temperature
thermovision
HV bushing
diagnostics
Opis:
W artykule omówiono podstawowe mechanizmy przebicia kompozytowej izolacji przepustów WN. Stwierdzono, że niekorzystny rozkład temperatury wewnątrz izolacji może być najczęściej występującą przyczyną uszkodzenia izolacji. Przedstawiono model cieplny kondensatorowych przepustów WN, z którego wynika że w głębokich warstwach izolacji w pewnych warunkach temperatura może przekroczyć wytrzymałość cieplną materiału. Model ten może być wykorzystany w diagnostyce przepustów opartej na cyfrowej analizie zdjęć termowizyjnych. Podano praktyczne przykłady zastosowania tej techniki diagnostycznej.
Basic mechanisms of HV bushing composite insulation breakdown are described in the paper. It was stated that the dominant cause of insulation failures is the thermal mechanism of breakdown, which develops in a few or a dozen and so hours. This opinion is confirmed by industrial experiences showing that most of failures happen in the afternoon hours after a hot day. The analysis of the problem showed that the main heat source in the core of a bushing are dielectric losses which depend on the local core temperature and the level of insulation deterioration. The volume temperature distribution in the bushing can be modeled with non-linear differential equation taking into consideration such parameters as thermal conductivity of an insulation, impregnate and porcelain housing, local values of dielectric losses and conditions of heat exchange in the bushing and in the interface porcelain-air. On this basis it was found that large changes of inside temperature in the insulation result in low changes of temperature on the surface of the porcelain housing. There was presented a heat model of HV condenser bushing which showed that in deep layers of insulation in some cases the temperature can exceed heat resistance of the material and cause intensive ageing process. Such heat model can be used in bushings diagnostics based on digital analysis of thermographs. Some practical examples were given for application of this diagnostic tool for technical condition assessment of 220 kV and 400 kV bushings. On the base of the model it was calculated that in the case of RIP 220 kV bushing for the temperature of housing 35?C inner temperature of the insulation can exceed critical value 90?C. There were made cross-sections of the insulation which confirmed the correctness of modeling, and assessment of technical condition, as highly deteriorated layers of insulation were found near the inner tube.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 5, 5; 491-495
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania modelowe izolatorów przepustowych typu OIP oraz RBPw aspekcie wystąpienia bubble effect
Investigations on models of OIP and RBP bushing insulators in aspect of bubble effect
Autorzy:
Morańda, H.
Przybyłek, P.
Walczak, K.
Mościcka-Grzesiak, H.
Powiązania:
https://bibliotekanauki.pl/articles/154311.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
izolatory przepustowe
efekt bąbelkowania
zawilgocenie izolacji
bushing insulators
bubble effect
moisture in insulation
Opis:
W artykule przedstawiono najważniejsze typy izolatorów przepu-stowych stosowanych w transformatorach. Omówiono procesy degradacji i zawilgacania izolacji celulozowej. Badano zjawisko bubble effect na modelach izolatorów przepustowych typu OIP i RBP.
One among the most dangerous effects that causes failure of a power transformer is the bubble effect (b.e.), i.e. a rapid release of water vapor from cellulose insulation after exceeding a critical temperature and a critical moisture content. The b.e. results in a rapid increase of tank pressure, which may thereafter cause an explosion and fire. The authors put forth the hypothesis that b.e. can possibly take place in the insulation of OIP (Oil Impregnated Paper) and RBP (Resin Bonded Paper) type of bushings. Development of the bubble effect was investigated on the models of OIP and RBP bushing insulators. In both types of models mineral oil and synthetic ester MIDEL 7131 were used. It was stated that b.e. may occur in both types of insulators, creating the possibility of serious failure of the transformer. Metal screens do not restrict the development of b.e., but they change the direction of water vapor migration. In the model, bubbles moved along metallic screens until they reached the edges of paper insulation layers. Also the presence of resin does not limit the development of b.e. It was shown that there existed a correlation between the bubbling initiation temperature and the water content in paper insulation. All the characteristics are presented together in Fig. 7. It can be seen that the model of the RBP bushing insulator has much lower initiation temperature of b.e. than that of the OIP bushing insulator. It is a negative feature of the RBP bushing insulator.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 2, 2; 172-175
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza możliwości wykorzystania kamery do pomiaru promieniowania ultrafioletowego emitowanego przez wyładowania niezupełne generowane na modelu izolatora przepustowego
Analysis of camera application possibility for measurement of ultraviolet radiation emitted by partial discharges generated on a bushing isolator model
Autorzy:
Frącz, P.
Powiązania:
https://bibliotekanauki.pl/articles/153841.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
wyładowania niezupełne powierzchniowe
promieniowanie ultrafioletowe
izolator przepustowy
surface partial discharges
ultraviolet radiation
bushing isolator
Opis:
Tematyka artykułu dotyczy określenia możliwości i wskazania zakresu zastosowania w diagnostyce izolatorów liniowych i stacyjnych kamery rejestrującej promieniowanie ultrafioletowe. W artykule przedstawiono wyniki pomiarów promieniowania ultrafioletowego emitowanego przez wyładowania niezupełne powierzchniowe generowane na modelu izolatora przepustowego umieszczonego w powietrzu. W ramach przeprowadzonych badań dokonano analizy wpływu szeregu czynników metrologicznych na uzyskiwane wyniki.
The scope of this paper considers possibility determination and application area indication of a camera for ultraviolet radiation recor-ding in diagnosis of linear isolators. Measurement results of ultraviolet radiation emitted by surface partial discharges (SPDs) generated on a bushing isolator mounted in the air are presented in the paper. Recording was performed by use a professional UVollé camera by the firm OFIL which enables for ultraviolet radiation measurement in the range of 50 nm to 280 nm. The main aim of works, performed under laboratory conditions, was to estimate the influence of supply voltage value changes in the range of 0 to 0.98 Up (breakdown voltage) on the counting quantity of partial discharges occurring on the surface of the ceramic bushing isolator. Moreover, the measurements and analyses performed, enclosed the influence estimation of the duration time of voltage applied to high tension electrodes, on the optical phenomena progress connected with SPDs generation. In the scope of works executed also the influence analyses of the distance between electrodes as well parameters of camera applied (sensitivity, amplification and size of the counting window) on the achieved results were investigated. Additionally, a comparative analysis of measurements results achieved for two diameters of the metal electrode (refill) for bushing isolator model was performed.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 4, 4; 387-390
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of optical signals emitted by SPD on an insulator model
Analiza sygnałów optycznych emitowanych przez WNZ powierzchniowe na modelu izolatora
Autorzy:
Fedorowicz, P.
Urbaniec, I.
Krzewiński, S.
Powiązania:
https://bibliotekanauki.pl/articles/155179.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
technika fotograficzna
wyładowania powierzchniowe
izolator przepustowy
izolator wsporczy
photographic technique
surface discharges
bushing
support/post insulator
Opis:
The paper presents the analysis results of optical signals measured by photographic technique. The optical signals were emitted by surface discharges occurring on two models of bushing and two models of post insulators during tests under laboratory conditions. The analyses were carried out in order to determine the impact of changes in distance between the HV source and the grounding on the intensity of emitted optical radiation according to red, green and blue components. In addition, the influence of discharge duration on the optical emission intensity was estimated.
W artykule przedstawiono wyniki analizy sygnałów optycznych mierzonych techniką fotograficzną. Sygnały optyczne emitowane były przez wyładowania niezupełne typu powierzchniowego, występujące na dwóch modelach izolatora przepustowego i na dwóch modelach izolatora wsporczego. Pomiary wykonano w warunkach laboratoryjnych. Analizy przeprowadzono w celu określenia wpływu zmiany odległości między źródłem wysokiego napięcia i uziemieniem na intensywność emitowanego promieniowania optycznego w zakresie barw czerwonej, zielonej i niebieskiej. Ponadto określono wpływ na intensywność emisji optycznej czasu trwania wyładowań. W pierwszej sekcji naświetlono problematykę zagadnienia oraz odwołano się do 10 prac dotyczących omawianej tematyki. W sekcji drugiej krótko scharakteryzowano izolatory wsporcze i przepustowe. W sekcji trzeciej opisano modele badanych izolatorów, zawarto trzy schematy blokowe oraz opisano metodologię pomiaru. W sekcji czwartej zawarto równania matematyczne wykorzystane do obliczenia intensywności składowych RGB zarejestrowanego promieniowania optycznego oraz osiem rysunków prezentujących wyniki przeprowadzonych analiz. W sekcji piątej szczegółowo omówiono otrzymane wyniki oraz zamieszczono podsumowanie uzyskanych charakterystyk.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 5, 5; 279-283
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ temperatury na odpowiedź dielektryczną przepustów transformatorowych wysokiego napięcia z izolacją stałą
Influence of temperature on dielectric response of HV transformers bushings with solid insulation
Autorzy:
Subocz, J.
Zenker, M.
Mrozik, A.
Powiązania:
https://bibliotekanauki.pl/articles/153835.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
przepust RBP
diagnostyka
temperatura
tanδ
wskaźnik polaryzacji Ka
RBP bushing
diagnostic
temperature
polarization index Ka
Opis:
W artykule zaprezentowano pomiary zjawisk relaksacyjnych w izolacji modelu przepustu transformatorowego typu RBP (z ang. Resin Bonded Paper). Badania przeprowadzono w różniej temperaturze metodami: FDS (Frequency Domain Spectroscopy) oraz metodą napięcia schodkowego SVM (Step Voltage Measurement) Analiza charakterystyk FDS wykazała występowanie dwóch procesów relaksacyjnych. Pierwszy dotyczy ß - relaksacji żywicy i papieru. Drugi związany jest z relaksacją granicy faz lub polaryzacji strukturalnej. W wysokiej temperaturze ujawnia się wpływ transportu masy jonowej. Stwierdzono, że w zależności od temperatury pomiaru, wartość tan?50Hz może być zdominowana przez różne procesy elektryczne, co utrudnia interpretację fizyczną na potrzeby diagnostyki izolacji. Zaobserwowano, że wartości wskaźnika polaryzacji Ka uzyskanych w teście SVM, są mało zależne od temperatury.
The main cause of transformer bushings failures are developed ageing processes which usually lead to thermal mechanism of breakdown. This may results in bushing explosion and oil leak and, subsequently, transformer fire and environment contamination. The presented problem of failures and new diagnostic methods of bushings is the field of interest of CIGRE WG A2.43. The paper describes measurements of relaxation phenomena in the insulation of RBP type transformer bushing (Resin Bonded Paper). The research was conducted with two methods: FDS (Frequency Domain Spectroscopy) and SVM (Step Voltage Measurement). The analysis of FDS results showed the presence of two relaxation processes. The first one comes from ß-relaxation of resin and paper, while the second one is related to interface or structural relaxation. In high temperature there is visible influence of ion mass transport. It was found that the values of tan?50Hz , according to the measurement temperature, might be activated by various electric processes, which makes physical interpretation for insulation diagnostics more difficult. The analysis of polarization index Ka values obtained from SVM test showed that they are slightly dependent on temperature.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 4, 4; 376-379
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena możliwości wykorzystania sygnałów emisji akustycznej do detekcji wyładowań niezupełnych w izolatorach przepustowych
Application possibility estimation of acoustic emission signals for detection of partial discharges in bushing isolators
Autorzy:
Cichoń, A.
Borucki, S.
Subocz, J.
Powiązania:
https://bibliotekanauki.pl/articles/153875.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
izolatory przepustowe
wyładowania niezupełne
metoda emisji akustycznej
diagnostyka elektroenergetyczna
bushing isolator
partial discharges
acoustic emission method
electric power diagnosis
Opis:
W artykule przedstawiono wyniki prac naukowo - badawczych związanych z detekcją wyładowań niezupełnych (WNZ) w izolatorach przepustowych z wykorzystaniem metody emisji akustycznej (EA). Badania przeprowadzono w warunkach laboratoryjnych wykorzystując model izolatora typu GSKTFK, w którym osłonę porcelanową zastąpiono obudową wykonaną z tworzywa sztucznego. Pomiary wykonywano w układach modelujących różne rodzaje uszkodzeń. Sygnały EA rejestrowano za pomocą piezoelektrycznego przetwornika stykowego przymocowanego do zewnętrznej części osłony izolatora. Analizę zarejestrowanych sygnałów przeprowadzono w dziedzinie czasowo - częstotliwościowej z wykorzystaniem krótkoczasowej transformaty Fouriera (STFT). Efektem przeprowadzonych prac było określenie możliwości wykorzystania metody EA do detekcji WNZ powstających na skutek różnych rodzajów defektów w izolacji papierowo - olejowej.
Reliable operation of an electric power system is connected with the necessity of maintenance of its particular elements for theirs good technical state. Important part of the electric power network is the high power transformer, which inherent elements are bushing isolators. Effective detection of PDs in inner part of the paper-oil isolation is one of the main conditions which assure safety operation of bushing isolators. Limited possibility for switching off the electric power devices is a reason for looking for new diagnostic methods enabling on-line measurements execution. Measurements results of AE signals generated in a bushing isolator: with defective inner paper-oil isolation, with presence of air blebs freely moving inside the isolation system, with forced motion of air blebs and with entered natural aging products of cellulose between the particular layers of the insulating system are presented in the paper. Results achieved in the scope of works performed confirmed the application possibility of AE method for technical state diagnosis of paper-oil insulation of bushing isolators in terms of PD appearance. During measurements of AE signals two kinds of PDs have been observed: electrical discharges in the inner part of paper-oil isolation and inside the air blebs. Time-frequency analysis has enabled to assign characteristic frequency bands to the particular PD types. This has created a basis for further works aiming development of research methodic enabling for AE signals measurement on bushing isolators under normal operation condition.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 4, 4; 348-351
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selected Aspects of Numerical Analyses of Transformers
Wybrane zagadnienia analizy numerycznej transformatorów
Autorzy:
Kasza, K.
Płatek, R.
Powiązania:
https://bibliotekanauki.pl/articles/156891.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
transformer
bushing
numerical analysis
manufacturing
operation
thermal shock
seismics
transformator
izolatory przepustowe
analiza numeryczna
produkcja
eksploatacja
szok termiczny
wstrząsy sejsmiczne
Opis:
The reliability and lifetime of a transformer depends on the quality of oil or epoxy insulation used in the transformer and attached accessories such as bushings. This paper presents selected aspects of the numerical analyses of transformers and transformer components with epoxy resin solid insulation. Reliability, durability and dielectric properties of the epoxy insulation depend strongly on the quality of a manufacturing process. For example, the residual stresses may be minimized by selecting the right process parameters. Computer simulations of the casting and curing process of high voltage coils of a dry transformer are applied for that purpose. Similar analyses are also possible for high voltage Resin Impregnated Paper (RIP) bushings. In this case computer simulations are also used for modeling the complex vacuum drying process, which is necessary to assure the high quality and reliability of the final product. A transformer and its components may be exposed to various environmental conditions during operation and even very extreme ones (e.g. large changes of the ambient temperature) should be taken into account during the design process. The computer simulations allow verification of a mechanical design of the dry transformer winding which is exposed to a thermal shock. The other example is evaluation of the mechanical resistance to seismic loads. Numerical analyses allow preliminary validation of the design of oil and dry transformers as well as bushings, which are expected to work in the area of earthquakes risk. By their application the design time and testing costs are much reduced.
Decydujący wpływ na niezawodność i czas życia transformatorów ma jakość izolacji olejowej lub żywicznej zastosowanej w transformatorze jak i również w komponentach bezpośrednio do niego podłączonych takich jak przepusty. W artykule przedstawiono wybrane aspekty analiz numerycznych dla transformatorów i komponentów z izolacją żywiczną. Niezawodność, trwałość i własności izolacji żywicznej zależą w dużej mierze od jakości procesu wytwarzania. Przykładowo zastosowanie symulacji komputerowych pozwala na analizę procesu zalewania i utwardzania uzwojeń wysokiego napięcia transformatorów suchych i dobór takich parametrów procesu by zminimalizować powstające naprężenia resztkowe. Podobne analizy są również możliwe dla wysokonapięciowych izolatorów przepustowych dla których wykonuje się również analizy procesu suszenia papieru. W trakcie eksploatacji transformator i jego komponenty narażone są na różnego rodzaju ekstremalne warunki zewnętrzne, których wystąpienie musi być uwzględnione w trakcie projektowania urządzeń. Przykładowo symulacje komputerowe pozwalają na sprawdzenie konstrukcji mechanicznej uzwojeń transformatorów suchych pod kątem ich odporności na drastyczne zmiany temperatury otoczenia. Innym przykładem jest ocena odporności na wstrząsy sejsmiczne. Analizy numeryczne pozwalają na wstępną weryfikację konstrukcji transformatorów olejowych i suchych oraz przepustów, które przewidziane są do pracy w rejonach zagrożonych trzęsieniami ziemi. Możliwe jest dzięki temu ograniczenie kosztów związanych z projektowaniem i testowaniem tych produktów.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 2, 2; 183-187
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-10 z 10

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies