Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Surge" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Thermographic and Electrical Test of Medium Voltage Surge Arresters
Autorzy:
Lisowska-Lis, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/114064.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
surge arresters
medium voltage
thermography
discharge current
cooling
Opis:
The paper presents the results of a thermal test (conducted with thermographic camera, coupled with an electrical test) of medium voltage metal–oxide surge arresters. Surge arresters (for Uc=18 kV) were tested for the leakage current and surface temperature: for 5 minutes under state 50 Hz alternating voltage 18 kV. The surface temperature of the MOAs correlates with an increase in leakage current. The result shows that the 0.6 mA AC leakage current in the medium voltage metal–oxide surge arrester (18 kV) is above the stable operating point, and the loss of electrical power is higher than the effective heat dissipation in the arrester. After 5 minutes of high voltage impact U = 18 kV, the surface temperature of the surge arrester was (4.32±0.55) K higher than the initial temperature. The IR camera can be used to detect the faults of ZnO metal–oxide surge arresters that lead to an increase in surface temperature.
Źródło:
Measurement Automation Monitoring; 2019, 65, 2; 60-63
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metody diagnostyczne ograniczników przepięć
Diagnostics methods of metal oxide surge arresters
Autorzy:
Chrzan, K.
Powiązania:
https://bibliotekanauki.pl/articles/157473.pdf
Data publikacji:
2003
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
metody diagnostyczne
ograniczniki przepięć
diagnostic methods
metal oxide surge arresters
Opis:
Opisano najważniejsze metody diagnostyczne ograniczników przepięć: pomiaru temperatury sondami TINYTALK lub SAW, kompensacji, pomiaru prądu całkowitego, harmonicznych prądu i składowej rezystancyjnej prądu.
The most important diagnostic methods of metal oxide surge arresters were described: temperature measurement using TINYTALK sensors or SAW sensors (Surface Acoustic Wave), compensation method, total current measurement, current harmonics measurement and resistive current measurement.
Źródło:
Pomiary Automatyka Kontrola; 2003, R. 49, nr 4, 4; 14-16
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of Axial Compressor Model Simplification and Mesh Density on Surge Margin Evaluation
Autorzy:
Muchowski, Rafał
Gubernat, Sławomir Maciej
Powiązania:
https://bibliotekanauki.pl/articles/2023311.pdf
Data publikacji:
2021
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
CFD
axial compressor
surge margin
jet engine
compressor map
grid dependence
Opis:
The menace of surge occurrence in the compressors is taken very seriously and its avoidance became a fundamental for the design of any modern jet engines. Nowadays, a problem with appropriate evaluation of the compressor surge margin while considering different simplifications of three-dimensional CFD model is still present. For that purpose, this article presents a comparison between the measurement data and several variants of 3D CFD models characterized by a specific mesh density. To calculate all the results on which the comparisons and conclusions are based, an 8-stage axial compressor is taken into account. Flow conditions of the machine are computed for three part load speeds: The low, the mid and the high one respecting the variable guide vanes schedule fitted to the specific load. For each of speed variants a four mesh configurations were generated: coarse, medium, fine and extra-fine. All speed configurations were treated with two different turbulence models – Wilcox k-ω and Menter’s SST k-ω, giving ultimately 15 CFD models, calculated with the TRACE solver using an initialization based on a circumferentially averaged flow solution delivered by the Streamline Curvature Method. During the study an additional assessment of reference grid independence was performed and the mesh convergence has been achieved. A comparison between turbulence models and the measurement proves that SST turbulence model is not well distributed through the speeds in compare to the measurement data and the Wilcox turbulence model. Inconsistency of sensitivity in the mesh coarsening for different rotational speeds was found. Increasing the mesh roughness level has to be executed for each speed separately. Overall compressor map shows that shift of the Pressure Ratio and the Mass Flow decreases with lower rotational speed. Neglecting the system add-ons like labyrinth sealing volumes, bleed-ports and other leakages has a visible influence on deviations from the measurements. Because of intended future use in design and optimization the “Medium” grid with Wilcox k-ω turbulence model was chosen, being a good representation of the Rig characteristics with reduction of the computing time.
Źródło:
Advances in Science and Technology. Research Journal; 2021, 15, 3; 243-253
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiar prądów udarowych z wykorzystaniem światłowodowego czujnika polarymetrycznego
The measurement of surge currents using a fibre optic polarimetric sensor
Autorzy:
Ginter, M.
Kaczmarek, Z.
Powiązania:
https://bibliotekanauki.pl/articles/156603.pdf
Data publikacji:
2006
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiar prądów udarowych
światłowodowy czujnik polarymetryczny
measurement of surge currents
fibre optic polarimetric sensor
Opis:
W pracy przedstawiono układ światłowodowego czujnika polarymetrycznego, w którym wykorzystuje się efekt Faradaya. Zaprezentowano wyniki badań eksperymentalnych proponowanego czujnika oraz wyznaczono jego podstawowe własności metrologiczne. Błąd nieliniowości czujnika w zakresie 0-1 kA jest nie większy niż 1,5%. Czujnik zastosowano do pomiaru natężenia prądu udarowego powstałego podczas niskonapięciowego wyładowania elektrycznego w wodzie. Zmierzone amplitudy prądu wyładowania są zgodne z wartościami amplitud wyznaczonymi z przesłanek teoretycznych.
In this paper a polarimetric fibre optic sensor, which uses the Faraday effect for the measurement of the current in conductor was described. Results of experimental research of the proposed measuring system were presented and the basic metrological properties were calculated. Nonlinearity of the sensor in range 0-1 kA is better than 1.5 %. The sensor was used to measure the intensity of the surge current arising during a low voltage electric discharge in water. The measured amplitudes of discharge current are consistent with values of amplitude calculated form theoretical premises.
Źródło:
Pomiary Automatyka Kontrola; 2006, R. 52, nr 4, 4; 36-38
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies