Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Comparison" wg kryterium: Temat


Tytuł:
Comparison of App Inventor 2 and Java in creating personal applications for Android on example of a Notepad
Autorzy:
Kowalczyk, R.
Turczyński, Ł.
Żyła, K.
Powiązania:
https://bibliotekanauki.pl/articles/957982.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
Java
App Inventor
Android
efficiency comparison
application usability comparison
Opis:
Nowadays, there is a common tendency to seek simpler and faster solutions that could be used in a process of software development. At the same time two other trends can be observed - rapid increase of mobile applications popularity and introducing IT concepts to non-IT specialists. This is why App Inventor 2 is one of the tools that software development community is interested in. The goal of this paper is to verify the possibility of using App Inventor as a tool for creating personal applications and compare it with possibilities given by Java, which is a native environment for Android platform. Comparison was based on application for managing personal text notes which was created in both solutions. The application had the same layout as well as analogical code, and it was the subject of performance tests followed by a survey. Performance test revealed that both implementations provided efficiency which is good enough for everyday use and small size personal applications. Survey participants preferred application built in Java due to its better responsiveness and visual appearance. Concluding, current shape of App Inventor, makes it useless for professionals, but useful for non-IT specialists for creating personal applications.
Źródło:
Advances in Science and Technology. Research Journal; 2016, 10, 31; 247-254
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Using Inconsistency Reduction Algorithms in Comparison Matrices to Improve the Performance of Generating Random Comparison Matrices with a Given Inconsistency Coefficient Range
Autorzy:
Kuraś, Paweł
Gerka, Alicja
Powiązania:
https://bibliotekanauki.pl/articles/2201885.pdf
Data publikacji:
2023
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
algorithm
pairwise comparison
inconsistency ratio
online tools
Opis:
The aim of this paper is to present a new method for generating random pairwise comparison matrices with a given inconsistency ratio (CR) interval using inconsistency reduction algorithms. Pairwise comparison (PC) is a popular technique for multi-criteria decision-making, its purpose is to assign weights to the compared entities, thus ranking them from best to worst. The presented method combines the traditional random generation of comparison matrices supported by inconsistency reduction algorithms: the “Xu and Wei” algorithm and the “Szybowski” algorithm. This paper presents research that shows an increase in performance when generating such matrices relative to the standard random comparison matrix generation procedure using the “Szybowski” algorithm. The other algorithms also improve the process, but to a lesser extent, making the “Szybowski” supporting algorithm the preferred solution for the new process. As a result of the research, a free online tool “PC MATRICES GENERATOR” has also been made available to efficiently generate a large number of comparison matrices with a given CR factor range, any matrix size, and any number of matrices, enabling much more efficient and less time-consuming research in many fields that use comparison matrices, as the analytic hierarchy/network process (AHP/ANP), ELECTREE, PAPRIKA, PROMETHE, VIKOR or the Best-Worst method (BWM).
Źródło:
Advances in Science and Technology. Research Journal; 2023, 17, 1; 222-229
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakteryzacja porównawcza współrzędnościowej techniki pomiarowej i tomografii komputerowej
Comparative characterisation of coordinate measuring technique and computed tomography
Autorzy:
Sładek, J.
Kowalski, M.
Ryniewicz, A.
Gacek, K.
Powiązania:
https://bibliotekanauki.pl/articles/152682.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
WMP
tomografia komputerowa
porównanie
CMM
computed tomography
comparison
Opis:
Niniejsze opracowanie jest związane z dwoma znacznie rozpowszechnionymi technikami pomiarowo-badawczymi o charakterze uniwersalnym, czyli takimi, które mogą być zastosowanie w różnych dziedzinach np. w technice i medycynie. Za cel przyjęto wstępne porównanie techniki współrzędnościowej z tomografią komputerową. Obydwie obecnie stosowane techniki wykorzystują zaawansowane oprogramowanie, ale działają wg zupełnie różnych zasad. W pracy opisano schematy strukturalne działania obu urządzeń , wektory oddziaływań pól pomiarowych i ich cechy charakterystyczne co do układów współrzędnych. Te cechy zostały odniesione do oceny odwzorowania kształtu powierzchni z regularnymi wgłębieniami. Przeprowadzono badania wstępne oraz zamieszczono przykładowe rezultaty pomiarów w postaci graficznej. Dla głównych kryteriów metrologicznych sporządzono porównanie cech w formie tabelarycznej i sformułowano wnioski z zaakcentowaniem zastosowań medycznych. W przypadku zastosowania TK ocena liczbowa odstępstw od kształtu nominalnego odbywa się zasadniczo na drodze porównawczej i jest wyraźnie mnie precyzyjna od oceny metodą współrzędnościową ale dla zastosowań medycznych wystarczająca.
This study is connected with two much prevalent measurement and testing techniques of a universal character, namely those that can be applied to various fields such as engineering and medicine. The aim is the initial comparison of coordinate techniques with computer tomography. These two techniques use advanced software, but operate on entirely different principles. The paper describes structural diagrams of two devices: Coordinate Measuring Machines and Computer Tomography, vectors of measurement fields impacts and their characteristics as a coordinate system. These features were related to the assessment of surface mapping of a spherical shape. Preliminary studies were conducted, and examples of measuring results in graphic form were provided. For the main metrological criteria the comparison of the characteristics in tabular form was made and the conclusions with emphasis on medical applications were formulated. In the case of Computer Tomography, the numerical evaluation of deviations from the nominal shape is primarily performed through the compari-son and is clearly less precise than the evaluation with coordinate method but is sufficient for medical applications.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 8, 8; 942-945
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
System do komparacji wzorców indukcyjności oparty na pomiarach napięć
System for inductance standard comparison based on voltage measurements
Autorzy:
Muciek, A.
Powiązania:
https://bibliotekanauki.pl/articles/151675.pdf
Data publikacji:
2002
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
komparacja wzorów indukcyjności
pomiary napięć
voltage measurements
inductance standard comparison
Opis:
Przedstawiono system do precyzyjnej komparacji wzorców indukcyjności oparty na metodzie trzech woltomierzy. Omówiono zasadę pracy systemu oraz sposób realizacji praktycznej. Wprowadzono i przeanalizowano wzory pozwalające na ocenę komparacji. Określono optymalne warunki pracy układu dla poszczególnych stosunków porównywanych wzorców. Otrzymane wyniki wykazują, że analizowany ukłąd pozwala, przy użyciu dostępnej na rynku aparatury, na komparację wzorców indukcyjności z niepewnością na poziomie lepszym niż 10 ppm w zakresie małych częstotliwości.
The system for inductance standard comparison based on the method of "three voltages" is presented. Operation of the system and its practical realisation is described. Uncertainty of comparison and choice of optimal comparison conditions are discussed. Practical examination and analysis shows that the presented system make it possible to compare inductance standards with uncertainty smaller than 10 ppm using the commercially available apparatus.
Źródło:
Pomiary Automatyka Kontrola; 2002, R. 48, nr 7/8, 7/8; 81-84
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Increasing metrological autonomy of in-plant measuring systems
Autorzy:
Mykyychuk, M.
Kochan, R.
Kochan, O.
Jun, S.
Stadnyk, B.
Stolyarchuk, P.
Powiązania:
https://bibliotekanauki.pl/articles/102200.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
metrological autonomy
in-plant measuring system
measuring equipment
metrological reliability
comparison
calibration
Opis:
The authors offer to solve the problem of providing traceability of measurements by increasing metrological autonomy of in-plant measuring systems. The paper shows the expedience of increasing metrological autonomy by creating a “virtual” reference. There are analysed possible variants of implementation of the “virtual” reference, which will provide high metrological stability of measurements at insignificant additional expenses. The authors point out the necessity of creation of universal technical and programmatic means of mutual comparison for the in-plant measuring systems to increase the reliability of measurements in the conditions of metrological autonomy.
Źródło:
Advances in Science and Technology. Research Journal; 2016, 10, 32; 193-197
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena wpływu impedancji pasożytniczych na dokładność cyfrowego niezrównoważonego komparatora impedancji
Evaluation of influence of stray impedances on digital unbalanced impedance comparator accuracy
Autorzy:
Rybski, R.
Kontorski, K.
Powiązania:
https://bibliotekanauki.pl/articles/151239.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
komparator impedancji
impedancje pasożytnicze
niepewność komparacji
impedance comparator
stray impedances
comparison uncertainty
Opis:
W pracy przedstawiono cyfrowy niezrównoważony komparator przeznaczony do porównań impedancji o dowolnym charakterze, w którym stosunek odpowiednich składowych impedancji wyznaczany jest na podstawie pomiaru stosunku spadków napięcia na porównywanych elementach impedancyjnych oraz napięcia niezrównoważenia układu. Przedstawiono wyniki analiz wpływu niepewności pomiaru napięcia niezrównoważenia na niepewność porównania impedancji dla porównań C-C i R-C. Podano wyniki badań wpływu impedancji pasożytniczych na błąd pomiaru składowych ortogonalnych napięcia niezrównoważenia oraz wpływ tego błędu na dokładność komparacji w układzie niezrównoważonym.
The paper presents an unbalanced digital comparator designed to compare an impedance of any kind. In the comparator the ratio of impedance components is determined by measuring the ratio of voltage drops across the compared impedance elements and the unbalance voltage of the circuit. Conditions of comparison of elements C-C and R-C (Eqs. (7), (8)) are given. The impedances of these elements are described by equation (6). The complex uncertainty of comparison (Eqs . (9), (10)) was calculated, and influence of the measurement uncertainty of the unbalance voltage orthogonal components on that voltage value was examined. Based on the proposed comparator equivalent circuit (Fig. 4), there was determined equation (13) for calculating the influence of stray impedances on the comparison result. Calculation results of the comparison impedance error C-C (Fig. 5) and R-C (Fig. 7) caused by the influence of stray imped-ances shown in Fig. 4 are presented in Section 4. Influence of the balance detector input resistance on the comparison error, when taking into account values of the input impedance of typical commercial data acquisition cards, was also examined. It was pointed out, that stray impedances cause systematic errors which should be taken in to account when determining the final comparison result. However, the uncertainty of determining these errors should be included in a budget of the comparison uncertainty.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 2, 2; 184-187
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Krajowe porównanie międzylaboratoryjne w dziedzinie czasu i częstotliwości – generator z mikroprocesorowym symulatorem sygnału z silnika krokowego zegara elektronicznego
In-country interlaboratory comparison in time and frequency domain – generator with microprocessor signal simulator of electronic watch stepper motor
Autorzy:
Osmyk, R.
Czubla, A.
Szterk, P.
Powiązania:
https://bibliotekanauki.pl/articles/156801.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
metrologia czasu i częstotliwości
porównania międzylaboratoryjne
time and frequency metrology
interlaboratory comparison
Opis:
W niniejszym artykule przedstawione zostały zagadnienia dot. organizowanych przez Główny Urząd Miar krajowych porównań międzylaboratryjnych w dziedzinie czasu i częstotliwości, w kontekście zastosowania w najnowszym porównaniu z 2011 r. jako wzorca przenośnego: generatora z symulatorem sygnału z silnika krokowego zegara elektronicznego. Podczas analizy wyników tego porównania zauważono istotny wpływ charakterystyk pracy stosowanych przez laboratoria chronokomparatorów na wyniki porównania, co przełożyło się na poprawę sposobu szacowania niepewności wyniku pomiaru przez laboratoria biorące udział w porównaniu i lepsze rozumienie uzyskiwanych wyników pomiaru.
This paper presents the issues concerning interlaboratory comparisons in time and frequency domain organized by the Central Office of Measures [5, 6, 7]. A short description of the purpose of such comparisons is presented in the first section. The second section contains description of the previous comparisons with a HS-1000 stopwatch as a portable standard which, however, was not stable long-term enough and was not resistant to influence of outside temperature (Fig. 1). In Section 3, there is presented a comparison of 2011 with a new model of the portable standard – a generator with a microprocessor signal simulator of the electronic watch stepper motor (Fig. 2 and 3) whose internal control system and motor stepper signal simulator were made in GUM. This standard is characterized by small dependence of the relative frequency deviation on changes of the outside temperature and simulates three detuning signals with a frequency of about 1 Hz. The analysis of the comparison results of 2011 (Section 4) was focused on the causes of a relatively large discrepancy between the results obtained by participants and the actual (correct) values of the simulated detuned signals in some cases. It was found that the characteristics of the work of the control instruments (clock testers) were critical and needed to be adequately taken into account in estimation of the measurement uncertainty. This comparison helped the participants to better understand the work of the clock testers and allowed them to verify and improve procedures of evaluation of the measurement results obtained with use of this type of equipment.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 7, 7; 601-604
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Weryfikacja skuteczności rozpoznawania defektów transformatorów olejowych przez wybrane metody DGA
Effectiveness verification of recognition of oil-filled transformer defects by selected DGA methods
Autorzy:
Piotrowski, T.
Powiązania:
https://bibliotekanauki.pl/articles/154951.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
transformator
diagnostyka
DGA
porównanie skuteczności metod
transformer
diagnosis
comparison of method effectiveness
Opis:
Zweryfikowano i porównano skuteczność wybranych metod DGA (Dissolved Gas Analysis) w rozpoznawaniu podstawowych typów defektów (wyładowania niezupełne, wyładowania, defekt cieplny). W tym celu przeprowadzono obliczenia na podstawie pomiarów gazów rozpuszczonych w oleju pochodzących z transformatorów o znanym rodzaju uszkodzenia. Zdefiniowano i obliczono prosty wskaźnik służący do celów porównawczych. Podano możliwości jego praktycznego zastosowania w procesie diagnostycznym.
Analysis of gases dissolved in oil is widely used in the diagnosis of transformers with oil-paper insulation. Detection of a fault requires knowledge of typical values of gas concentrations which are specific for particular group of transformers. In Poland the values were determined by Energopomiar [1]. To identify the nature of the defect, there can be used a number of universal methods. The effectiveness of selected DGA (Dissolved Gas Analysis)methods in the diagnosis of basic types of faults (partial discharges, discharges, thermal defect) was verified and compared. For this purpose, the calculations based on measurements of the gases dissolved in the oil of transformers with a known type of faults were carried out. A simple factor for com-parative purposes was also defined and calculated. The possibility of its practical application to the diagnostic process was presented. The analyzes performed show, among others, that none of the methods is able to detect the correct faults in all cases of provided data. The number of erroneous diagnoses depend on the actual type of the fault and is the largest for PD. Carrying out calculations with simultaneous use of several methods eliminates, to a large extent, the possibility of making a mistake or lack of diagnosis.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 2, 2; 129-132
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rozważania o podstawach tribologii. Cz. 15, Metodologiczne podstawy badań porównawczych w tribologii
A discussion about the fundamental problems of tribology. Pt. 15, Methodological basis of comparative study in tribology
Autorzy:
Leszek, W.
Powiązania:
https://bibliotekanauki.pl/articles/189679.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
metoda porównawcza
zasady tribologii porównawczej
porównywanie obiektów
comparative study
rules of comparative tribology
objects comparison
Opis:
W opracowaniu przedstawiono ogólne zasady i tok postępowania w badaniach porównawczych oraz warunki porównywalności obiektów, zjawisk, procesów, metod badawczych i zdań ogólnych. Zagadnienia te odniesiono do elementów składowych wiedzy o tarciu, zużyciu i smarowaniu. W zakończeniu omówiono warunki porównywalności wyników badań tribologicznych.
The paper presents the general rules and the process of a comparative study and the assumptions of the comparison of the objects, phenomenon, processes, methods and general sentences. These issues are related to the components of the knowledge of friction, wear and lubrication. The conclusion presents the possibility of comparing the tribological research results.
Źródło:
Tribologia; 2013, 1; 9-23
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Akredytacja laboratorium wyposażonego we współrzędnościową maszynę pomiarową
Accreditation of the CMMs laboratories
Autorzy:
Swornowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/151644.pdf
Data publikacji:
2008
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
współrzędnościowa technika pomiarowa
akredytacja WMP
porównanie standardów
coordinate measuring technique
CMMs accreditation
comparison of specification standards
Opis:
Aby uzyskać produkt o najwyższej jakości potrzebny jest odpowiedni system jakości. Na uzyskanie wysokiej jakości w procesie produkcyjnym wpływa wiele czynników, w tym czynnik związany z pomiarem. Co raz częściej spotyka się w przemyśle współrzędnościową maszynę pomiarową jako "uniwersalne" urządzenie kontrolne. To niewątpliwie skomplikowane urządzenie pomiarowe wymaga odpowiedniego poświadczenia swojej dokładności w certyfikacie wzorcowania. Konieczne minimalne wymagania jakie powinien spełniać system zapewnienia jakości zostały zdefiniowane w normach ISO 9000. W przedsiębiorstwie struktura organizacyjna i procedury systemu zapewnienia jakości udokumentowane są w księdze jakości. W normie ISO 9000:2000 wprowadzono podejście procesowe po to, aby osiągnąć zadowolenie odbiorcy. Praktycznie to odbiorca wyrobu narzuca wymagania jakie musi spełnić producent, w tym również w aspekcie metrologicznym. W szczególności dotyczy to metody kalibracji WMP wybieranej przez odbiorcę. W artykule zwrócono uwagę na róż-\nice występujące w krajowych i międzynarodowych normach.
To obtain the product about the best quality is necessary the suitable system of the quality. On the obtainment of the high quality in the manufacturing process influences many factors, in this the measuring - factor. Often in the industry one comes together the coordinate measuring machine as "the universal" monitor. This complicated measuring - device demands the suitable certificate of the accuracy in the calibration certificate. The necessary minimum requirements for a QM system are set out in EN ISO 9000 standard. By quality management system (QM system), we mean the structural and procedural organization for performing tasks. In the ISO 9000:2000 norm one introduced the approach of a law suit for this, to reach the satisfaction of the receiver. The receiver forces what requirements must be realized by the producer, in this also in the metrological aspect. Especially refers this of the CMMs method calibration. In this paper looks at some of the difficulties caused by the lack of national or international standards for calibration of CMMs.
Źródło:
Pomiary Automatyka Kontrola; 2008, R. 54, nr 9, 9; 658-661
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multiplekser na stanowisku do realizacji jednostki miary indukcyjności własnej w GUM
Digitally controlled switch for realization of inductance unit at the Central Office of Measures (GUM, Warsaw)
Autorzy:
Musioł, K.
Kampik, M.
Popek, G.
Powiązania:
https://bibliotekanauki.pl/articles/152777.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
komparacja wzorców
multiplekser wzorców indukcyjności
komparator wzorców indukcyjności
comparison of inductance standards
digitally controlled switch
comparator bridge
Opis:
W artykule przedstawiono koncepcję modernizacji stanowisk do realizacji jednostki Henra w Państwowych Instytucjach Metrologicz-nych. Opisano stanowisko do odtwarzania jednostki w Głównym Urzędzie Miar w Warszawie i - za zgodą GUM - zamieszczono wyniki badań zmodernizowanego stanowiska wyposażonego w multiplekser wzorców indukcyjności własnej. Stabilne i zgodne z otrzymanymi przed modyfikacją wyniki badań zmodernizowanego stanowiska w Głównym Urzędzie Miar świadczą o możliwości zastąpienia przełącznika mechanicznego MCS1 multiplekserem DCS2 przy zachowaniu dobrej powtarzalności i dokładności wyników komparacji.
A concept of modernization of stations for realization of inductance unit at National Metrology Institutes is presented in the paper. The concept is based on appliance a new digitally controlled switch for comparison of inductance standards. A station at the Central Office of Measures (GUM) in Warsaw is described. The national primary inductance standard at the GUM consists of four GR1482H inductors (Tab. 1) kept in the thermostat (Fig. 1). The old station at the GUM (Fig. 2) was modernized by the applying the digitally controlled switch DCS2 (Fig. 3) in 2007 [7, 8, 9]. Then the comparison measurements at the old and the new stations were performed to confirm accuracy and usefulness of the new digitally controlled switch. Results of delta L measurements for national inductance standards at the GUM before and after the modernization are presented in Tab 2. In Tab. 3 the corrected results of deltas taking into account reversion of standards are presented. Very stable (and similar to the results achieved at the old station) results of measurements prove that the old mechanical switch can be replaced by the new digitally controlled one. The new digitally controlled switch connected with the modern comparator bridge enables automation of the comparison process and gives a new possibilities of investigation of the measuring current, time and temperature on the comparison results.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 8, 8; 844-847
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania biegłości i porównawcze NDT realizowane przez Sekcję Badań Materiałowych Klubu POLLAB
Autorzy:
Lipnicki, Marek
Powiązania:
https://bibliotekanauki.pl/articles/107906.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
badania NDT
badania nieniszczące
badania porównawcze
badania biegłości
POLLAB
NDT
non-destructive evaluation
comparison
evaluation
proficiency testing
Źródło:
Badania Nieniszczące i Diagnostyka; 2019, 2; 20-22
2451-4462
2543-7755
Pojawia się w:
Badania Nieniszczące i Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania właściwości metrologicznych cyfrowych źródeł dwufazowych
Metrological properties of digital two-phase voltage sources
Autorzy:
Musioł, K.
Met, A.
Kampik, M.
Powiązania:
https://bibliotekanauki.pl/articles/972216.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
cyfrowe źródła napięcia przemiennego
komparacja impedancji
źródła dwufazowe
digital AC voltage sources
impedance comparison
two-phase generator
Opis:
W pracy zostały przedstawione wyniki badań właściwości metrologicznych dwu wybranych komercyjnych cyfrowych dwufazowych źródeł napięcia przemiennego. Badania były prowadzone pod kątem wykorzystania tych źródeł w precyzyjnych układach służących do komparacji impedancji. Otrzymane wyniki badań wzajemnej stabilności amplitud i stabilności fazy poddanych analizie źródeł potwierdzają, iż realne jest uzyskanie niepewności komparacji wzorców impedancji na poziomie 10-5 zarówno przy wykorzystaniu w układzie generatora Tabor Electronics WW2572A, jak i źródła Audio Precision AP SYS-2722.
Metrological properties of commercially available digital two-phase generators are considered in the paper. Two sinewave sources: Tabor Electronics WW2572A and Audio Precision AP SYS-2722 were examined for use in high-precision impedance comparison bridges. The relative stability of the output voltage amplitudes was tested in the measuring circuit shown in Fig. 4. All measurements were made in an electromagnetically screened room shown in Fig. 3. The results obtained (Figs. 5 and 6) prove the short-term magnitude stability of the WW2572A on the level of 15 V/V and the stability of the AP SYS-2722 better than 10 V/V. The phase shift stability was checked with use of a lock-in amplifier Stanford Research System SR830. The measurements were taken for four different phase shifts = CH1 - CH2: 0, -90°, +90°, 180° between the output voltages of Channel 1 and 2. The test results presented in Figs. 7 and 8 show that the relative short-term phase stability is equal to 4 mrad for the WW2572A and 6 mrad for the AP SYS-2722. Total Harmonic Distortion factors of the sinewaves generated by the examined sources were also checked. THD on the level of -100 dB proves very high signal purity. The results of the relative amplitude and phase stability measurements prove that it is possible to obtain the uncertainty of impedance comparison on 10-5 level using the WW2572A or AP SYS-2722 generator in the comparator bridge shown in Fig. 1
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 5, 5; 410-413
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Równoległa implementacja algorytmu winnowing dla operacji strumieniowej analizy tekstu
Parallel Winnowing Implementation for text stream analysis
Autorzy:
Wielgosz, M.
Żurek, D.
Pietroń, M.
Dąbrowska-Boruch, A.
Wiatr, K.
Powiązania:
https://bibliotekanauki.pl/articles/154404.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
n-gramowy model
eksploracja danych
przetwarzanie strumieniowe
GPGPU
n-gram-based model
document comparison
GPU
information retrieval
Opis:
W ramach praca przeprowadzona została analiza możliwości wykorzystania algorytmu winnowing do strumieniowego przetwarzania informacji tekstowej. W szczególności nacisk został położony na operacje generacji odcisku jako jej zredukowanej reprezentacji wiadomości tekstowej. Autorzy przeprowadzili szereg eksperymentów, w celu określenia efektywności działania algorytmu oraz możliwego do uzyskania przyspieszenia obliczeń, z wykorzy-staniem węzła procesorów Intel Xeon E5645 2.40GHz oraz karty GPU Nvidia Tesla m2090.
There are several models available for information retrieval and text analysis but the two are considered to be the dominant ones, namely Boolean and the vector space model (VSM). A model maps the existing words or text into a new representation space. This paper presents a boolean n-gram-based algorithm - winnowing for fast text search and comparison of documents with main focus on its implementation and performance analysis. The algorithm is used to generate fingerprints (i.e. a set of hashes) of the analyzed documents. A dedicated test framework was designed and implemented to handle the task of the algorithm evaluation which utilizes PAN test corpus and programming environment. Several tests were conducted in order to determine the comparison quality of the obfuscated and not obfuscated text for the winnowing algorithm and different window and n-gram size. The tests revealed interesting properties of the algorithms with respect to comparison of documents as well as defied the limits of their applicability. The n-gram-based algorithms due to their simplicity are well suited for hardware implementation. Thus, the authors implemented compu-tationally demanding part of both fingerprint generation both on CPU and GPU. Performance measurements for Intel Xeon E5645, 2.40GHz and Nvidia Tesla m2090 implementation of Ngram-based algorithm show approximately 14x computational speedup.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 5, 5; 309-312
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bilateralne porównania dokładności realizacji punktu potrójnego wody w INTiBS i VSL w Holandii
Bilateral comparison of water triple point realization at INTiBS and VSL – the Netherlands
Autorzy:
Kowal, A.
Szmyrka-Grzebyk, A.
Peruzzi, A.
Powiązania:
https://bibliotekanauki.pl/articles/972221.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
wzorce temperatury
punkty stałe skali temperatury
porównania kluczowe
CMC
temperature standards
fixed points of temperature scale
key comparison
Opis:
INTiBS – depozytariusz wzorca państwowego – zobowiązany jest do potwierdzania swoich kompetencji przez udział w międzynarodowych porównaniach kluczowych. Wymagania te wynikają z porozumienia CIPM MRA. Porównania dokładności realizacji punktu potrójnego wody w INTiBS – elementu wzorca państwowego - zostały przeprowadzone w Instytucie Metrologii w Holandii (VSL). Różnica temperatur punktu potrójnego wody uzyskiwanych w komórkach VSL i INTiBS wynosiła 2,9 μK przy niepewności pomiaru u = 46 μK.
In Poland the National Temperature Scale is maintained by two distinct National Laboratories, by the Central Office of Measures – GUM in Warsaw, for long-stem thermometers at temperatures above the argon triple point with a temperature -189,3442 °C up to + 961,78 °C, and by the Institute of Low Temperature and Structure Research – INTiBS in Wroclaw, for capsule thermometers at temperatures below the water triple point down to 13,8033 K (the triple point of hydrogen). Since both laboratories use the water triple point but only GUM could participated in EURAMET.T-K7, a separate bilateral comparison was set up with the Dutch Metrology Institute - VSL, in order to create a direct reference to CCT-K7 for INTiBS. A temperature difference of the triple point of water at the INTiBS reference cell and the VSL water cell determined during the comparisons was equal to 2,9 μK with a standard uncertainty u = 46 μK for k = 1. The comparison gives a direct linkage to the EURAMET. T-K7. The equivalence between the INTiBS standard TINT(TPW) and the European Reference Value TERV(TPW) is 1,2 μK with an expanded uncertainty U = 111 μK for k = 2.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 5, 5; 437-440
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies