Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Kowalski, K. J." wg kryterium: Autor


Wyświetlanie 1-3 z 3
Tytuł:
Application of surfactants to reduction in of fractures ceramic materials during drying
Zastosowanie surfaktantów do redukcji pęknięć w materiałach ceramicznych podczas suszenia
Autorzy:
Kowalski, S. J.
Kulczyński, K.
Powiązania:
https://bibliotekanauki.pl/articles/2072416.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
kaolin clay
convective drying
material damage
acoustic emission
surfactants
glinka kaolinowa
suszenie konwekcyjne
destrukcja materiału
emisja akustyczna
surfaktanty
Opis:
The main goal of this work was to investigate the effect of stearate sodium sulfate surfactant on the reduction of drying induced stresses in clay-like materials during drying. The experiments were carried out on cylindrical samples molded of kaolin-clay wetted with water solution of different surfactant concentrations. The samples after moisture distribution leveling were subjected to convective drying in hot air at temperature of 90°C in a dryer chamber. The acoustic emission method was used to monitor the stress development in drying samples. Moreover, the samples were observed and photographed to visualize their shrinkage during drying.
Głównym celem tej pracy było zbadanie efektu wpływu surfaktantu (stearynian sodu) na redukcję naprężeń suszarniczych w materiałach glino- podobnych podczas suszenia. Eksperymenty przeprowadzono na próbkach cylindrycznych wykonanych z glinki kaolinowej zwilżanej roztworem wodnym o różnych stężeniach surfaktantu. Próbki, po ujednorodnieniu rozkładu wilgoci, były poddane konwekcyjnemu suszeniu w gorącym powietrzu o temperaturze 90°C w suszarce komorowej. Do monitorowania rozwoju naprężeń suszarniczych wykorzystana była metoda emisji akustycznej. Ponadto próbki były obserwowane i fotografowane, aby uwidocznić skurcz materiału podczas suszenia.
Źródło:
Inżynieria i Aparatura Chemiczna; 2013, 4; 343--344
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakteryzacja porównawcza współrzędnościowej techniki pomiarowej i tomografii komputerowej
Comparative characterisation of coordinate measuring technique and computed tomography
Autorzy:
Sładek, J.
Kowalski, M.
Ryniewicz, A.
Gacek, K.
Powiązania:
https://bibliotekanauki.pl/articles/152682.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
WMP
tomografia komputerowa
porównanie
CMM
computed tomography
comparison
Opis:
Niniejsze opracowanie jest związane z dwoma znacznie rozpowszechnionymi technikami pomiarowo-badawczymi o charakterze uniwersalnym, czyli takimi, które mogą być zastosowanie w różnych dziedzinach np. w technice i medycynie. Za cel przyjęto wstępne porównanie techniki współrzędnościowej z tomografią komputerową. Obydwie obecnie stosowane techniki wykorzystują zaawansowane oprogramowanie, ale działają wg zupełnie różnych zasad. W pracy opisano schematy strukturalne działania obu urządzeń , wektory oddziaływań pól pomiarowych i ich cechy charakterystyczne co do układów współrzędnych. Te cechy zostały odniesione do oceny odwzorowania kształtu powierzchni z regularnymi wgłębieniami. Przeprowadzono badania wstępne oraz zamieszczono przykładowe rezultaty pomiarów w postaci graficznej. Dla głównych kryteriów metrologicznych sporządzono porównanie cech w formie tabelarycznej i sformułowano wnioski z zaakcentowaniem zastosowań medycznych. W przypadku zastosowania TK ocena liczbowa odstępstw od kształtu nominalnego odbywa się zasadniczo na drodze porównawczej i jest wyraźnie mnie precyzyjna od oceny metodą współrzędnościową ale dla zastosowań medycznych wystarczająca.
This study is connected with two much prevalent measurement and testing techniques of a universal character, namely those that can be applied to various fields such as engineering and medicine. The aim is the initial comparison of coordinate techniques with computer tomography. These two techniques use advanced software, but operate on entirely different principles. The paper describes structural diagrams of two devices: Coordinate Measuring Machines and Computer Tomography, vectors of measurement fields impacts and their characteristics as a coordinate system. These features were related to the assessment of surface mapping of a spherical shape. Preliminary studies were conducted, and examples of measuring results in graphic form were provided. For the main metrological criteria the comparison of the characteristics in tabular form was made and the conclusions with emphasis on medical applications were formulated. In the case of Computer Tomography, the numerical evaluation of deviations from the nominal shape is primarily performed through the compari-son and is clearly less precise than the evaluation with coordinate method but is sufficient for medical applications.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 8, 8; 942-945
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Akcelerometryczny system badania i analizy chodu
Gait analysis system based on accelerometers
Autorzy:
Maj, P.
Barczewska, K.
Drozd, A.
Kowalski, J.
Powiązania:
https://bibliotekanauki.pl/articles/154893.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
czujniki przyspieszenia
chód
system bezprzewodowy
accelerometers
gait
wireless system
Opis:
Przedmiotem pracy jest system badania i analizy chodu. Pomiary przyspieszeń wykonywane są w różnych punktach anatomicznych z wykorzystaniem trójosiowych czujników przyspieszenia, transmisja danych odbywa się w standardzie Bluetooth, a do akwizycji wykorzystano przenośny komputer. Oprogramowanie służące do zapisu, przetwarzania i analizy danych zostało napisane w środowisku LabVIEW. Badania chodu przeprowadzono na 17 ochotnikach. Uzyskano parametry związane ze zdarzeniami w cyklu chodu, a także wysokie wartości czułości (91-94%) i specyficzności (88-89%) detekcji zdarzeń oraz satysfakcjonującą wartość parametru %R&R (16%).
Gait analysis provides useful information about spatio-temporal parameters [10, 11], stability and balance [7], progression of the diseases (Parkinson, Huntington) [7, 8], results of rehabilitation [6] or shock attenuation [7, 9]. The paper describes the accelerometer-based system designed for motion and gait examination. The system consists of two measurement modules with triaxial ADXL accelerometers (Tab. 1), portable computer and software implemented in LabVIEW environment. The system features data transmission via a Bluetooth network and during examination the data is received on a portable computer, visualized on a graph and written in a text file (Fig. 2). The text file has a special header which contains information about the examined person, anatomical axes and a name of the place of module attachment. The all information is introduced by a user at the beginning of the examination. After signal processing, several parameters are calculated: mean duration of the gait cycle, mean duration of swing and stance phases in percentage of the gait cycle, acceleration range (Fig. 1, Tab. 2) [15]. Detection of gait cycle events (heel strike, toe off) is based on the analysis of local extremes of the parameter RSS (Formula 1) [16]. For every anatomical point there is also visualized a graph with accelerations for the whole mean gait cycle (Fig. 4). At the end of data analysis, an examination report as a Microsoft Word document file is prepared. System tests were performed on 17 volunteers (Fig. 3) who underwent gait examination. Depending on the goal, only one or both modules were used. There were different places of module attachment: ankles, knees, hips, sacrum, neck and head. High values of sensitivity (91-94%) and specificity (88-89%) of event detection as well as satisfactory value of %R&R parameter (16%) were obtained.
Źródło:
Pomiary Automatyka Kontrola; 2012, R. 58, nr 4, 4; 327-330
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies