Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Kabaciński, M." wg kryterium: Autor


Wyświetlanie 1-5 z 5
Tytuł:
Influence of disturbed flow after an elbow on metrological properties of a Flow Averaging Tube
Autorzy:
Kabaciński, M.
Powiązania:
https://bibliotekanauki.pl/articles/114498.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
velocity profile measurement system
averaging Pitot tube
Flow Averaging Tube K-factor
elbow flow
automated test stand
Opis:
Experimental results of air velocity profiles and Flow Averaging Tubes (FAT®) K-factor measured behind an elbow are presented in this paper. The pipeline diameter was D=150 mm, while the range of mean velocities w=9…30 m/s. Velocity profiles were determined both in the vertical and horizontal plane in the respective distances L/D of a pipeline from 3 to 18. In the places of the measured velocity profiles, three cross-sections of flow averaging tubes (circular, streamlined and two-profile) were placed to determine the characteristics of K-factor. Moreover, a fully automated test stand is presented in this paper. The completed experiment allows shortening the distance between an elbow and a flowmeter installation place and informing about the value of a correction factor, which can be used to minimize the measurement uncertainty of the air flow rate. It was stated that the horizontal plane is better to install a probe because of the velocity profile and better results of repeatability.
Źródło:
Measurement Automation Monitoring; 2016, 62, 1; 7-16
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ deformacji profilu prędkości na wartość współczynnika przepływu przepływomierza z rurką uśredniającą ciśnienie dynamiczne
Influence of velocity profile deformation on flow averaging tube flow coefficient
Autorzy:
Kabaciński, M.
Pochwała, S.
Powiązania:
https://bibliotekanauki.pl/articles/151449.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
profil prędkości
pomiary przepływów
rurki uśredniające ciśnienie dynamiczne
niepewność pomiaru
velocity profile
flow measurements
flow averaging tubes
measurement uncertainty
Opis:
W pracy przedstawiono zasadę działania rurek uśredniających oraz stanowisko do ich wzorcowania. Zaprezentowano wyniki badań eksperymentalnych pomiaru strumienia powietrza przepływomierzami spiętrzającymi w strefie zaburzonego przepływu za pojedynczym kolanem. Określono profile prędkości w wybranych miejscach instalacji. Wyznaczono charakterystyki współczynnika przepływu K dla rurki o kształcie opływowym. Podano wartości współczynnika korekcyjnego umożliwiającego zmniejszenie niepewności pomiaru przepływu rurką uśredniającą. Wykazano, że lokalizacja przepływomierza poniżej 5D za kolanem powoduje istotny wzrost niepewności pomiaru.
This paper presents experimental results of the air flow across an obstacle formed by a 90 degree segmented elbow. The internal diameter of the pipeline was D=152 mm, while the range of the mean velocities w = 10 30 m/s. The velocity profiles were determined (using Prandtl tube) both in the vertical and horizontal plane [12] in the relative distances L/D of the pipeline from 3 D to 20 D (Figs. 5 and 6). In the places of the established velocity profiles a streamlined flow averaging tube [7] was placed to determine the characteristics of the flow coefficient K (Figs. 8 and 9) as a function of the mean velocity (and Re number). The scope of this paper is also to present an automated test stand (equipped with a dedicated computer program - data acquisition) for calibrating flowmeters. The results of the experiments are given in the form of charts and compared. Analysis of the effect of changing the position of the averaging probe (vertical, horizontal) was conducted together with examination of the influence of the distance behind the obstacle (elbow) on the K-factor value. The realized experiment allowed shortening the distance between the obstacle and flowmeter installation place and informing about the correction factor value which can be used to minimise the uncertainty of the air flow rate measurement (Fig. 10). It was assumed that the horizontal plane is better for probe installation because of almost axi-symmetrical velocity profile and better repeatability of measurement points (K-factor changes by about 1%).
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 2, 2; 157-160
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Flow averaging tube geometry improvement for K-factor stability increase
Autorzy:
Kabaciński, M.
Pospolita, J.
Powiązania:
https://bibliotekanauki.pl/articles/114099.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
velocity profiles
air flow measurement
closed conduits
automated test stand
flow averaging Pitot tube
Opis:
Fluid flow around two-profile averaging differential pressure sensor was investigated in this paper. Research concentrated particularly on fluid movement direction and velocity over the investigated flow sensor. Analysis was conducted experimentally in low velocity wind tunnel. Because of large number of measuring points placed very close to each other, it was decided that velocity profile measurement will be performed by means of fully automated test stand. Due to a recirculation of the stream in the vicinity of the probe tested in the wind tunnel, an original two-direction probe was used. A linear module with a stepper motor formed an integral part of the measurement system. The location of the measuring probe, the possibility of adjusting stream mean velocities and data acquisition was undertaken by means of a dedicated program. The above mentioned investigation method helped to improve the metrological properties of the flowmeter applying non symmetrical probe cross-section forced air stream to be redirected in the desired direction. This modification significantly increased K-factor value and stability of air flow through the contraction of the flowmeter.
Źródło:
Measurement Automation Monitoring; 2017, 63, 1; 2-5
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigations of the vibration effect in a measurement system for air flow phenomena in large pipelines
Autorzy:
Kabaciński, M.
Pawliczek, R.
Powiązania:
https://bibliotekanauki.pl/articles/114391.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
air flow
vibration
strain gauge
virtual instrument
Opis:
A measuring system for investigation of the air flow phenomena in large tubes is presented in this paper. The main goal is to measure and analyze the vibration effect of a sensing element used for air velocity and air stream measurement. It was observed that some vibrations occurred and involved damage effect in the flow sensor. The measuring system is based on the strain gauge technology with the use of a virtual instrument in the laboratory equipment. The presented system allows measuring, identifying and analyzing vibrations of the sensor in time and frequency domains. It was created as a virtual instrument, very easy to implement into the entire control system of the stand. It was found that the load of the sensing element was asymmetric and the mean load value, compared to variable loads, arose from disturbances of the air flow around the sensor. It was observed for the examined velocities of the air stream in the range up to 35 m/s.
Źródło:
Measurement Automation Monitoring; 2016, 62, 3; 96-99
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Własności metrologiczne i możliwości zastosowań przepływomierzy z rurkami spiętrzającymi oraz mikrozwężkami
Metrological properties and ability applications of self averaged pitot probes and micro - venturi tubes
Autorzy:
Pospolita, J.
Kabaciński, M.
Chwastek, C.
Powiązania:
https://bibliotekanauki.pl/articles/158087.pdf
Data publikacji:
2004
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
własności metrologiczne
zastosowania przepływomierzy
rurki spiętrzające
mikrozwężki
metrological properties
ability of applications
flowmeters
Opis:
W pracy przedstawiono rozwiązania konstrukcyjne przepływomierzy piętrzących, w których czujnikami są rurki uśredniające ciśnienie dynamiczne oraz mikrozwężki. Podano przykłady numerycznych badań piętrzących czujników przepływu. Omówiono ich własności metrologiczne i eksploatacyjne. Podano przykłady zastosowań.
Constructions of impact flowmeters based on averaged pitot probes and micro - venturi tubes are presented in this paper. Examples of numerical simulations of impact flowmeters are displayed. Metrological and operating properties of these probes are shown. Moreover examples of their applications are given.
Źródło:
Pomiary Automatyka Kontrola; 2004, R. 50, nr 12, 12; 22-25
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies