Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "probe" wg kryterium: Temat


Wyświetlanie 1-9 z 9
Tytuł:
Probe radius correction methods - review and comparison of existing methods
Autorzy:
Rak, A.
Woźniak, A.
Powiązania:
https://bibliotekanauki.pl/articles/385250.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
coordinate measuring machine (CMM)
scanning probe
probe tip radius correction
Opis:
Scanning technology has been becoming more common then ever. Scanning offers new and effective possibilities of measurement. Nowadays planning, production and assembling without high accurate metrology is impossible. Measurement of small, curved elements became much easier with great development of mechanical components of measure machines, such as: guideways, transducers, bearings, servomechanisms. All this improvement made possible to collect with good accuracy points in high density. Algorithms, and computer software were greatly improved as well. Especially, many efforts were put on probe radius correction algorithms development. In this paper a review and a comparison of probe radius correction methods are shown.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2009, 3, 4; 169-171
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermionic vacuum arc diagnostic using emissive probe
Autorzy:
Tiron, V.
Aniculaesei, C.
Popa, G.
Powiązania:
https://bibliotekanauki.pl/articles/385290.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
thermionic vacuum arc
emissive probe
Opis:
In this paper, experimental results are presented on study of the copper thermionic vacuum arc using emissive probe. Experimental results show that plasma potential is direct related to the discharge voltage and it shows nonlinear distribution from the anodic melted spot towards to the plasma extremity.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2009, 3, 4; 147-149
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurements of plasma diffusion coefficient in Pilot-PSI device using Katsumata probe
Autorzy:
Solomon, M. L.
Mihaila, I.
Anita, V.
Costin, C.
Popa, G.
van der Meiden, H.
Al, R.
van Rooij, G.
Cardozo, N. L.
Rapp, J.
Ionita, C.
Stärz, R.
Schrittwieser, R.
Powiązania:
https://bibliotekanauki.pl/articles/385269.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
Katsumata probe
magnetized plasma
diffusion coefficient
Opis:
Cross-field transport of particles and energy is a major issue in magnetized fusion-relevant plasmas, due to its relevance for plasma confinement. In this paper Katsumata probe measurements performed in Pilot-PSI linear magnetized plasma device are presented. The plasma diffusion coefficient in perpendicular direction to the magnetic field was estimated from the measurements.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2009, 3, 4; 160-162
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Seebeck coefficient measurement by Kelvin-probe force microscopy
Autorzy:
Ikeda, H.
Salleh, F.
Asai, K.
Powiązania:
https://bibliotekanauki.pl/articles/384281.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
Seebeck coefficient
Kelvin-probe force microscopy
nanostructure
Opis:
In order to measure the Seebeck coefficient of nanometer-scale thermoelectric materials, we propose a new technique in which the thermoelectric-motive force (TEMF) is evaluated by Kelvin-probe force microscopy (KFM). In this study, we measured the Seebeck coefficient of an n-type Si wafer. The surface-potential difference between the high- and low-temperature regions on the Si wafer increases with increasing temperature difference. This indicates that the TEMF can be measured by KFM. The Seebeck coefficient evaluated from the surface-potential difference is 0.71š0.08 mV/K, which is close to that obtained by the conventional method.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2009, 3, 4; 49-51
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detection of individual dopants in singe-electron devices - a study by KFM observation and simulation
Autorzy:
Ligowski, M.
Moraru, D.
Miftahul, A.
Tarido, J. C.
Mizuno, T.
Tabe, M.
Jabłoński, R.
Powiązania:
https://bibliotekanauki.pl/articles/385159.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
single dopant
Kelvin Probe Force Microscope
single-electron transfer
Opis:
Single electron devices (SEDs) are candidates to become a keystone of future electronics. They are very attractive due to low power consumption, small size or high operating speed. It is even possible to assure compatibility with present CMOS technology when natural potential fluctuations introduced by dopant atoms are used to create quantum dots (QD). However, the main problem of this approach is due to the randomness of dopant distribution which is characteristic for conventional doping techniques. This leads to scattered characteristics of the devices, which precludes from using them in the circuits. In these work we approach the problem of correlating the distribution of QD's with the device characteristics. For that, we investigate with a Kelvin probe force microscope (KFM) the surface potential of Si nanodevice channel in order to understand the potential landscape. Results reveal the features ascribable to individual dopants. These findings are supported also by simulation results.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2009, 3, 4; 130-133
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyznaczenie dwuwymiarowej niedokładności pomiaru wewnątrzobrabiarkowego system pomiarowego z zastosowaniem sondy OMP60
Determination of two-dimensional measurement uncertainty of measurement system inside machine tool with use of inspection probe OMP60
Autorzy:
Jacniacka, E.
Semotiuk, L.
Babkiewicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/275816.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
niepewność pomiaru
sonda przedmiotowa
obrabiarka CNC
uncertainty
inspection probe
CNC machine tool
Opis:
Sondy przedmiotowe coraz częściej są standardowym wyposażeniem obrabiarek CNC. Wykorzystywane są dopomiaru wymiarów geometrycznych między zabiegami technologicznymi oraz do kontroli po zakończeniu obróbki. W artykule przedstawiono i porównano wyniki wyznaczania dwuwymiarowej niedokładności pomiaru z wykorzystaniem płytek wzorcowych i pierścienia wzorcowego.
Inspection probes are becoming a standard equipment of CNC machine tools. They are used to measure dimensions between technological operations, and to control after machining is completed. This paper presents results of determining two-dimensional uncertainty with use of gauge blocks and gauge rings.
Źródło:
Pomiary Automatyka Robotyka; 2012, 16, 10; 68-73
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The identification method of the sources of radiated electromagnetic disturbances on the basis of measurements in the near-field zone
Autorzy:
Trzcinka, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/2141812.pdf
Data publikacji:
2021
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
electromagnetic compatibility
EMC
near electromagnetic field
radiated emission
near-field probe
source of disturbance
Opis:
The paper presents results of tests of a simple device, consisting in the location of a source of disturbance emission by means of measurements within the near field with manual positioning of the measuring probe. The effectiveness of the source of disturbance location was finally verified by a positive result of the radiated emission tests in the EMC laboratory using a standardised method.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2021, 15, 4; 53-64
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Two dimensional model of CMM probing system
Autorzy:
Ali, Salah H.R.
Powiązania:
https://bibliotekanauki.pl/articles/950738.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
CMM
trigger probe
stylus tip
tip root errors
and two-dimensional-model (2DM)
Opis:
A coordinate measuring machine (CMM) as an automation technology is playing the key role in the modern industry to improve the measurement accuracy. Accurate probing that is computer controlled is the current trend for the next generation of coordinate metrology. However, the CMM probing system is limited by its dynamic root errors that may markedly affect its response characteristics. In this paper, dynamic response errors of CMM measurements have been analyzed. The adopted probe stylus sizes throughout the course of measurements are found to cause some waviness errors during CMM operations due to each of the prescribed angle of the probe tip contact point with the specimen surface and the radius of the stylus tip. Variations in the geometry of the stylus have their consequent effects on its inherent intrinsic dynamic characteristics that in turn would cause relevant systematic root errors in the resulted measurements. Unforeseeable geometrical errors of a CMM using a ductile touch-trigger probing system have been characterized theoretically. These results are analyzed in order to investigate the effect of the dynamic root errors in the light of six probe stylus tip of the situation into account when assessing the accuracy of the CMM measurements. Analytical approaches have been applied on a developed two dimensional model (2DM) of stylus tip to demonstrate the capability of such approaches of emphasizing the root error concept using the strategy of CMM ductile trigger type of probe.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2010, 4, 2; 3-7
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elimination of the Phase Mismatch Error in PP Probe Using Synchronous Measurement Technique
Wykorzystanie synchronicznego pomiaru do eliminacji błędu fazowego w sondzie typu PP
Autorzy:
Raczyński, Michał
Powiązania:
https://bibliotekanauki.pl/articles/2090886.pdf
Data publikacji:
2022
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
PP-probe
sound intensity
phase mismatch error
sonda natężeniowa typu PP
błąd niedopasowania fazy
pomiar natężenia dźwięku
Opis:
The paper presents a modification of the pressure-pressure (PP) sound intensity measurement method. In the proposed solution simultaneous measurement with a pair of microphones (used in the classical PP probe) is replaced by a sequence of measurements taken with a single microphone placed in successive positions. This approach requires an additional (reference) microphone to synchronize the successive measurements. Although, in the process of calculating the sound intensity only the signal from the measurement microphone is used. Thanks of this the errors associated with differences in the frequency responses of the measurement microphones (especially phase mismatch error) that occurs in the classical PP method are eliminated. This approach simultaneously increases the random error and limits the measurements to periodic signals only. The article presents the principle of operation of the classical PP probe and the currently used methods of phase mismatch error elimination based on pre-calibration of the probe. Next, the theoretical basis of the proposed measurement method is described. To verify the effectiveness of phase mismatch error elimination in the proposed method, an experiment was conducted. It consisted in estimation the angle of incidence of an acoustic wave under controlled conditions in an anechoic chamber. The measurement was carried out with the classical PP probe and with the modified method. Measurements were made for different sound sources (a loudspeaker set and a small electrical device). In the final part of the paper, the results are discussed, both methods (classical and modified) are compared and potential applications of the proposed method are indicated.
W artykule zaprezentowano modyfikację metody pomiaru natężenia dźwięku z wykorzystaniem sondy PP (ang. pressure-pressure). W zaproponowanym rozwiązaniu jednoczesny pomiar ciśnienia akustycznego za pomocą dwóch mikrofonów pomiarowych (używanych w klasycznej sondzie PP) został zastąpiony sekwencją pomiarów dokonywanych jednym mikrofonem pomiarowym umieszczanym w kolejnych pozycjach. Zaproponowana metoda pozwala na eliminację błędu związanego z niejednakowymi odpowiedziami częstotliwościowymi (głównie fazowymi) mikrofonów użytych w klasycznej sondzie PP. Jej zastosowanie jest ograniczone do pomiaru sygnałów okresowych. Jednocześnie wzrasta błąd przypadkowy, który można jednak wyeliminować metodami statystycznymi. Pomimo, że zaproponowane podejście wymaga zastosowania mechanizmu synchronizacji pomiarów i użycia w tym celu dodatkowego mikrofonu pomocniczego, to w samym procesie wyznaczania natężenia dźwięku bierze udział jedynie sygnał z mikrofonu pomiarowego. W artykule zaprezentowano zasady pomiaru natężenia dźwięku za pomocą klasycznej sondy PP oraz obecnie stosowane metody eliminacji błędów związanych z niedopasowaniem charakterystyk częstotliwościowych mikrofonów, bazujące na wstępnej kalibracji sondy. Następnie przedstawione są teoretyczne podstawy zaproponowanej metody pomiarowej. Aby zweryfikować jej skuteczność przeprowadzono eksperyment pomiarowy polegający na pomiarze kąta padania fali akustycznej w ściśle określonych warunkach w komorze bezechowej. Eksperyment przeprowadzono z wykorzystaniem klasycznej metody PP oraz z wykorzystaniem zaproponowanej metody zmodyfikowanej. Dokonano pomiarów dla różnych źródeł dźwięku (zestawu głośnikowego oraz małego urządzenia elektrycznego). W końcowej części artykułu wyniki porównawcze są poddane dyskusji w celu wskazania potencjalnych zastosowań zaproponowanej metody.
Źródło:
Pomiary Automatyka Robotyka; 2022, 26, 2; 35--46
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-9 z 9

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies