Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Kotlarz, W." wg kryterium: Wszystkie pola


Wyświetlanie 1-4 z 4
Tytuł:
Proposed Tasks of Enceladus Missions’ Instrumentation in the Context of Their Astrobiological Goals
Proponowane zadania aparatury misji na Enceladus w kontekście ich celów astrobiologicznych
Autorzy:
Kubiak, Katarzyna
Kotlarz, Jan
Zalewska, Natalia
Zielenkiewicz, Urszula
Powiązania:
https://bibliotekanauki.pl/articles/2068630.pdf
Data publikacji:
2020
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
Enceladus
multispectral cameras
mass spectrometry
astrobiology
kamery wielospektralne
spektrometria mas
astrobiologia
Opis:
Enceladus, Saturnian satellite, is a very significant object for astrobiologists due to the presence of liquid water that forms the ice-covered ocean. Water ice geysers escape from the south pole region through cracks in the ice shield. During the Cassini flight, the probe took samples of plumes matter recognizing besides other methane and molecular hydrogen. Since then, hypotheses have been formulated that life forms similar to those found in the Lost City Hydrothermal Field in the Atlantic ocean bottom may occur near Enceladus’ hydrothermal chimneys. In our work, we analyzed the possibility of a microbial factor detection in the Enceladus geysers. We used as model organisms selected extremophiles. We investigated multi-spectral cameras and mass spectrometers intended for use in mission proposals to Enceladus: Enceladus Orbiter, Enceladus Life Finder, The Explorer of Enceladus and Titan and THEO mission. The review pointed that the configuration of mass spectrometers and the proposed parameters of scientific orbits are appropriate for detecting volatile organic compounds corresponding to selected microorganisms such as aldehyde, ethanol, benzene, toluene, indole, or violacein. The possible presence of a microbiological component with physical dimensions in the order of several micrometres can only be observed for areas of geyser formation at their higher density (> 10 ppm) and with the occurrence of the “snowing microbes” phenomenon. We have found that particularly useful optical channels are 780–975nm, 860–910 nm, and 5.0–5.3 μm.
Enceladus, księżyc Saturna, jest obiektem bardzo ważnym dla astrobiologów ze względu na obecność ciekłej wody, która tworzy ocean pokryty lodem. Gejzery lodu wodnego wydobywają się z regionu bieguna południowego przez pęknięcia w pokrywie lodowej. Sonda Cassini pobrała podczas lotu próbki pióropusza, rozpoznając, między innymi, metan i wodór cząsteczkowy. Od tamtej pory sformułowano hipotezy, że w pobliżu hydrotermalnych kominów Enceladusa mogą występować formy życia podobne do występujących w polu hydrotermalnym Lost City na dnie Atlantyku. W naszej pracy przeanalizowaliśmy możliwość wykrycia czynnika mikrobiologicznego w gejzerach Enceladusa. Posłużyliśmy się wybranymi ekstremofilami jako organizmami modelowymi. Przebadaliśmy kamery wielospektralne i spektrometry masowe przeznaczone do wykorzystania w proponowanych misjach do Enceladusa: Enceladus Orbiter, Enceladus Life Finder, The Explorer of Enceladus and Titan oraz misji THEO. Ich przegląd wykazał, że konfiguracja spektrometrów masowych oraz proponowane parametry orbit są odpowiednie do wykrywania lotnych związków organicznych odpowiadających wybranym mikroorganizmom, takich jak aldehyd, etanol, benzen, toluen, indol czy wiolaceina. Ewentualną obecność składnika mikrobiologicznego o wymiarach fizycznych rzędu kilku mikrometrów można zaobserwować jedynie dla obszarów formowania się gejzerów przy ich większej gęstości (> 10 ppm) oraz przy występowaniu zjawiska „snowing microbes”. Stwierdziliśmy, że szczególnie przydatne kanały optyczne to 780-975 nm, 860-910 nm oraz 5,0-5,3 μm.
Źródło:
Pomiary Automatyka Robotyka; 2020, 24, 4; 47--56
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detekcja biomarkerów w pióropuszach gazowych za pomocą kamery wielospektralnej w projektowanej misji Enceladus Orbiter (NASA)
Detection of Biomarkers in Gas Plumes Using a Multi-Spectral Camera in the Proposed Enceladus Orbiter Mission (NASA)
Autorzy:
Zalewska, N.
Kotlarz, J.
Kacprzak, M.
Korniluk, T.
Powiązania:
https://bibliotekanauki.pl/articles/277007.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
Enceladus
biomarkery
analizy wielospektralne
sensory
biomarkers
multispectral analysis
sensors
Opis:
W publikacji podjęto się próby odpowiedzi na pytanie o możliwość analizy składu chemicznego pióropuszy, wykorzystując ich wielospektralne zobrazowania wykonane za pomocą projektowanych dla nowej misji układów optycznych. Stosując teoretyczną analizę transmitancji warstw gazowych złożonych z H2O i CO2 oraz na podstawie przyjętego fizycznego modelu transmitancji promieniowania przez warstwę gazu widocznego na tle o ustalonej reflektancji wybrano pasmo optyczne 0,73 μm pozwalające na najlepsze rozróżnienie tych dwóch substancji. W celu walidacji otrzymanego wyniku przeprowadzono eksperyment fotografując za pomocą kamery wielospektralnej Quercus.6 strumienie gazowe złożone z obu biomarkerów na tłach o wysokiej (> 0,95) oraz niskiej (< 0,05) reflektancji w paśmie światła widzialnego i NIR. Pozyskane dane potwierdziły wynik analizy sygnatur spektralnych transmitancji obu biomarkerów. Na podstawie otrzymanego w doświadczeniu wyniku ustalono brzegowe parametry sensora i układu optycznego dla projektowanej dla orbitera kamery wielospektralnej pozwalające na oszacowanie względnej zawartości H2O i CO2 w pióropuszach fotografowanych na tle przestrzeni kosmicznej z dokładnością 2%: kanał optyczny λ = 0,730 ±0,020 μm, prędkość względna między orbiterem a księżycem v < 200 m/s, czas ekspozycji tEXP < 12 ms, iloczyn współczynnika efektywności kwantowej całego układu optycznego i względnych różnic reflektancji rejestrowanych obiektów w wybranym kanale ≥ 2,5%, wielkość pojedynczego piksela na detektorze CCD ≥ (3,75 · 3,75) μm2, głębokość studni potencjału piksela CCD ≥ 12 400 e, zapis danych RAW co najmniej 8-bitowy. Otrzymany optymalny kanał nie był rejestrowany za pomocą stosowanych w poprzednich misjach sensorów optycznych MVIC. Stosowanie opisanej metodyki rozróżniania biomarkerów jest możliwe pod warunkiem, że jeden z czterech kanałów optycznych projektowanej kamery MAC będzie zawierać kanał 0,73 μm.
The cause of the cryovolcanic activity on the Enceladus south hemisphere and related to this activity gas plumes are one of the biggest mysteries of the outer solar system moons. The possibility of the existence of the ocean under Enceladus icy outer layer was confirmed through direct chemical plumes composition measurement during Cassini close flyby 168.2 km over moon’s surface. Three out of the four main plumes components are standard biomarkers (H2O, CO2 and CH4). Physical plumes parameters variability observed also by Cassini, possibility of drawing conclusions about cryovolcanic activity reasons and biotic causes of biomarkers presence in plumes are important reasons of new, dedicated to Enceladus observation, NASA’s mission development. In this paper we are asking about possibility of Enceladus plumes chemical components analysis using multispectral imaging by projected for this new mission sensors. We chose band 0.73 μm for H2O and CO2 distinguish using theoretical transmittance gas layers analysis and physical radiation transmittance through gas layer visible on the background material with defined constant reflectance model. In order to validate this result an experiment was conducted. Using multispectral camera Quercus.6 we photographed H2O and CO2 gas layers visible on the high (> 0.95) and low (< 0.05) visible light and NIR reflectance backgrounds. The results confirmed theoretical spectral transmittance analysis of those two biomarkers. Based on this result we established boundary parameters of the sensor and optical system projected for the orbiter allowing relative content of the biomarkers estimation with precision up to 2%: optical band λ = 0.730 (± 0.020) μm, relative velocity between orbiter and moon v < 200 m/s, exposition time tEXP < 12 ms, quantum efficiency of the whole optical system and two biomarkers in selected wavelength reflectance difference product ≥ 2,5%, single CCD pixel physical size ≥ (3,75 · 3,75) μm2, potential well depth for one CCD pixel ≥ 12 400 e, RAW data record at least 8-bit. Optimal result waveband wasn’t recorded before using MVIC optical systems during past missions. If we want to apply proposed in this paper biomarkers distinguish methodology one out of four optical channels of the MAC camera projected for the new mission should cover also selected wavelength.
Źródło:
Pomiary Automatyka Robotyka; 2017, 21, 3; 35-44
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie taboru kolejowego jako nośnika sensorów w zakresie monitoringu środowiska naturalnego
The Use of Rolling Stock as a Carrier of Sensors in the Field of Environmental Monitoring
Autorzy:
Kotlarz, Jan
Szypulski, Maciej
Kubiak, Katarzyna
Siwiński, Jarosław
Powiązania:
https://bibliotekanauki.pl/articles/277640.pdf
Data publikacji:
2019
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
IoT
monitoring środowiska
edge device
transport kolejowy
LoRaWAN
environmental monitoring
railway transport
Opis:
Rozwój rynku IoT w Polsce może stać się czynnikiem upowszechniającym monitoring środowiska naturalnego i zwiększającym automatyzację tego działania. Pomiary wykonywane obecnie albo z użyciem zobrazowań niskorozdzielczych (dane satelitarne), albo punktowych (in situ) są obarczone błędami wynikającymi ze zbyt małej szczegółowości danych lub niskich rozdzielczości czasowych. Często kampanie pomiarowe są czasochłonne i generują wysokie koszty. Od wielu lat, zarówno w Europie, jak i w Ameryce Północnej, prowadzone są badania mające na celu umożliwienie użycia sensorów umiejscowionych na kolejowych platformach mobilnych (lokomotywy, wagony) w monitoringu środowiskowym. W publikacji przedstawiamy możliwość implementacji sensorów akustycznych, obrazowych oraz skaningu laserowego. Przedstawiamy przykłady zastosowań oraz odpowiadamy na pytanie o możliwość ich implementacji w Polsce.
The development of the IoT market in Poland may become a factor that propagates the monitoring of the natural environment and increases the automation of it. Measurements performed currently either using low-resolution images (satellite data) or locally (in situ) are burdened with errors due to insufficient data detail or low time resolutions. Often, measurement campaigns are timeconsuming and generate high costs. For many years, both in Europe and North America, research has been carried out to enable the use of sensors located on railway mobile platforms (locomotives, carriages) in environmental monitoring. The publication presents the possibility of implementing acoustic and image sensors as well as laser scanning. We present examples of applications and answer the question about the possibility of their implementation in Poland.
Źródło:
Pomiary Automatyka Robotyka; 2019, 23, 2; 45-52
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ typu podszytu na teledetekcyjny pomiar defoliacji Quercus robur L. w zakresie 640-820 nm
The impact of the type of undergrowth on the remote sensing defoliation measurement of Quercus robur L. in the range: 640-820 nm
Autorzy:
Kotlarz, J.
Kacprzak, M.
Rotchimmel, K.
Tkaczyk, M.
Powiązania:
https://bibliotekanauki.pl/articles/275799.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
teledetekcja lasu
zdrowotność
zdjęcia wielospektralne
bliska podczerwień
UAV
defoliacja
remote sensing of the forest
health status
multispectral images
near infrared
defoliation
Opis:
Jednym z objawów zamierania drzewostanów dębowych w Europie jest wysoka defoliacja obserwowana u drzew o słabej zdrowotności. Na potrzeby corocznego monitoringu dotkniętych patogenem Phytophtora powierzchni badawczych projektu HESOFF w Zakładzie Teledetekcji Instytutu Lotnictwa podjęto próbę wytworzenia metodyki oceny defoliacji za pomocą lotniczych zdjęć wielospektralnych. W tym celu w lipcu 2015 r. za pomocą Platformy Wielosensorowej QUERCUS.6 wykonano zdjęcia lotnicze badanego kompleksu leśnego (zakres 0,46–0,82 μm). Na podstawie zdjęć wykonano pomiar reflektancji dla każdego z badanych dębów oraz porównano pozyskane w ten sposób dane radiometryczne z ocenionym metodą tradycyjną poziomem defoliacji. Na podstawie uzyskanych korelacji wykazano, że pomiar defoliacji jest możliwy przy zastosowaniu kanałów optycznych: 0,46–0,52 μm oraz 0,67–0,82 μm. Wykazano ponadto, że do poprawnego pomiaru defoliacji zaproponowaną w tym artykule metodą, konieczne jest uwzględnienie typu podszytu, który ma decydujący wpływ na obserwowaną reflektancję.
One of the symptoms of dieback of oak stands in Europe is high defoliation, observed in trees with poor health. For the purposes of annual monitoring (in research project HESOFF) of the research area affected by the pathogen Phytophthora, in the Remote Sensing Department of Institute of Aviation was made attempt to develop a proper methodology for defoliation evaluation with multispectral aerial images use. For this purpose in July 2015 with the use of the Multisensory Platform QUERCUS.6 aerial photos of the test forest complex were made (range: 0.46–0.82 μm). Based on the photos, reflectance measurements for each of investigated oaks were made and acquired parameters have been compared with defoliation level obtained by conventional methods. Based on these correlation has been demonstrated that defoliation measurement is possible with use of optical channels: 0.46–0.52 μm and 0.67–0.82 μm. It was also shown that for correct defoliation measurement with proposed in this article methodology it is necessary to take into account the type of underbrush, which has a decisive influence on the observed reflectance.
Źródło:
Pomiary Automatyka Robotyka; 2018, 22, 1; 5-10
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies