Tytuł:
Optimization of the Synthesis Parameters and Analysis of the Impact Sensitivity for Tetrazene Explosive
Autorzy:
Li, Jin-Shuh
Chang, Chun-Chieh
Lu, Kai-Tai
Powiązania:
https://bibliotekanauki.pl/articles/358591.pdf
Data publikacji:
2020
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Przemysłu Organicznego
Tematy:
tetrazene
yield
optimal synthesis parameters
Taguchi design method
Opis:
Tetrazene [1-(5-tetrazolyl)-4-guanyltetrazene hydrate] is widely used in ordnance systems as a sensitizer of primer compositions, for use in both percussion and stab applications. It can be synthesized by reacting aminoguanidinium bicarbonate (AGB) with sodium nitrite (NaNO2) in the presence of acetic acid. However, little is known about its optimal synthesis parameters in the manufacturing process. In this study, Taguchi's experimental design method was used to further improve the yield of tetrazene. Under the condition that the molar ratio of AGB to NaNO2 was fixed at 1.0:1.2, a L9(33) orthogonal array with three control factors and three levels for each control factor was used to design nine experimental conditions. The experimental data were transformed into a signal-to-noise (S/N) ratio to analyze and evaluate the experimental conditions of the optimal parameter combination for the maximum yield of tetrazene. Verification of the results indicated that the optimal synthesis parameters were as follows: pH value of AGB solution was 5.0, reaction temperature was 35 °C and reaction time was 6 h; the maximum yield of tetrazene could reach 83.7%. Furthermore, the synthesized tetrazene was identified and characterized by elemental analysis (EA), nuclear magnetic resonance spectroscopy (NMR), Fourier transform infrared spectroscopy (FTIR), optical microscopy (OM),particle size distribution analysis (PSDA), X-ray diffraction (XRD) and differential scanning calorimetry (DSC), and its impact sensitivity was determined using a BAM Fallhammer apparatus and the Bruceton analysis method.
Źródło:
Central European Journal of Energetic Materials; 2020, 17, 1; 5-19
1733-7178
Pojawia się w:
Central European Journal of Energetic Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-1 z 1

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies